Navigation in ACL reconstruction - comparison with conventional measurement tools.

Restoration of rotational and translational stability is a goal of ACL reconstruction. Intraoperative instability measurements of AP translation and rotation are not well established clinically. We compared navigated measurements of tibial AP translation and rotation with mechanical measuring devices: the KT 1000 and a modified goniometer tool. Tests were repeated with intact and dissected ACLs, and measures of translation and rotation statistically compared. There was no significant difference in AP translation between navigation, 3.2 mm (range 1-6 mm) and the KT 1000, 4.8 mm (range, 4-7 mm) in our experimental set up (p>0.05). Tibial rotation revealed no significant difference, 0.12 degrees (range, 0 degrees -1 degrees ) between navigation and goniometer (p>0.05). Total range of rotation was 4.2 degrees (range, 2 degrees -6 degrees ) in intact and 7.05 degrees (range, 4 degrees -9 degrees ) in dissected ACLs (p<0.05). Stability parameters in ACL navigation can be measured precisely under laboratory conditions and results are not significantly different from mechanical testing devices.

[1]  A A Amis,et al.  Knee joint motion: Description and measurement , 1998, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[2]  Markus Degenhart Computer-navigated ACL reconstruction with the OrthoPilot. , 2004, Surgical technology international.

[3]  R Perez,et al.  Effect of optical digitizer selection on the application accuracy of a surgical localization system-a quantitative comparison between the OPTOTRAK and flashpoint tracking systems. , 1999, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[4]  Mary T. Gabriel,et al.  Distribution of in situ forces in the anterior cruciate ligament in response to rotatory loads , 2004, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  Freddie H. Fu,et al.  Biomechanical Analysis of an Anatomic Anterior Cruciate Ligament Reconstruction , 2002, The American journal of sports medicine.

[6]  G. Barrett,et al.  The effect of intraoperative isometric measurement on the outcome of anterior cruciate ligament reconstruction: a clinical analysis. , 1996, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[7]  M. Marcacci,et al.  New intraoperative protocol for kinematic evaluation of ACL reconstruction: preliminary results , 2006, Knee Surgery, Sports Traumatology, Arthroscopy.

[8]  Kozo Nakamura,et al.  Endoscopic anterior cruciate ligament reconstruction using a computer-assisted fluoroscopic navigation system , 2006, Journal of orthopaedic science : official journal of the Japanese Orthopaedic Association.

[9]  M Tew,et al.  Is the KT1000 knee ligament arthrometer reliable? , 1989, The Journal of bone and joint surgery. British volume.

[10]  K. Bernsmann,et al.  [Using the CAS (computer-assisted surgery) system in arthroscopic cruciate ligament surgery--adaptation and application in clinical practice]. , 2001, Zeitschrift fur Orthopadie und ihre Grenzgebiete.

[11]  Freddie H. Fu,et al.  The Effectiveness of Reconstruction of the Anterior Cruciate Ligament with Hamstrings and Patellar Tendon: A Cadaveric Study Comparing Anterior Tibial and Rotational Loads , 2002, The Journal of bone and joint surgery. American volume.

[12]  D. Banzer,et al.  Positioning of total knee arthroplasty with and without navigation support. A prospective, randomised study. , 2003, The Journal of bone and joint surgery. British volume.

[13]  D. Felson,et al.  Cruciate ligament integrity in osteoarthritis of the knee. , 2005, Arthritis and rheumatism.

[14]  M Tingart,et al.  [Navigated implantation of total knee endoprostheses in secondary knee osteoarthritis of rheumatoid arthritis patients as compared to conventional technique]. , 2004, Zeitschrift fur Rheumatologie.

[15]  G. Fanelli,et al.  The predictive value of intraoperative KT-1000 arthrometer measurements in single incision anterior cruciate ligament reconstruction. , 1996, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[16]  S Martelli,et al.  Validation of a new protocol for computer-assisted evaluation of kinematics of double-bundle ACL reconstruction. , 2006, Clinical biomechanics.

[17]  Niels W L Schep,et al.  Intersurgeon variance in computer-assisted planning of anterior cruciate ligament reconstruction. , 2005, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.

[18]  Musa Citak,et al.  Computer Assisted Pelvic Surgery: Registration Based on a Modified External Fixator , 2003, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[19]  Daniel Kendoff,et al.  The role of navigation in knee surgery and evaluation of three-dimensional knee kinematics , 2005 .

[20]  M. Englund,et al.  High prevalence of knee osteoarthritis, pain, and functional limitations in female soccer players twelve years after anterior cruciate ligament injury. , 2004, Arthritis and rheumatism.

[21]  A A Amis,et al.  Intraoperative measurement of knee kinematics in reconstruction of the anterior cruciate ligament. , 2002, The Journal of bone and joint surgery. British volume.

[22]  T. Gill,et al.  The Effect of Anterior Cruciate Ligament Reconstruction on Knee Joint Kinematics under Simulated Muscle Loads , 2005, The American journal of sports medicine.

[23]  Markus Tingart,et al.  CT-free computer-assisted total knee arthroplasty versus the conventional technique: radiographic results of 100 cases. , 2004, Orthopedics.

[24]  J. Koh Computer-assisted navigation and anterior cruciate ligament reconstruction: accuracy and outcomes. , 2005, Orthopedics.

[25]  Satoshi Toh,et al.  Intraoperative evaluation of the anatomical double-bundle anterior cruciate ligament reconstruction with the OrthoPilot navigation system. , 2005, Orthopedics.

[26]  E P Wilkinson,et al.  Comparative tracking error analysis of five different optical tracking systems. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[27]  Alex E Staubli,et al.  Computer aided ACL reconstruction. , 2004, Injury.

[28]  B Jaramaz,et al.  Accuracy in tunnel placement for ACL reconstruction. Comparison of traditional arthroscopic and computer-assisted navigation techniques. , 2001, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[29]  Ramprasad Papannagari,et al.  The 6 Degrees of Freedom Kinematics of the Knee after Anterior Cruciate Ligament Deficiency , 2006, The American journal of sports medicine.

[30]  S. Woo,et al.  The forces in the anterior cruciate ligament and knee kinematics during a simulated pivot shift test: A human cadaveric study using robotic technology. , 2000, Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association.