Atomic force microscope cantilevers as encoders for real-time forward and backward displacement measurements

Atomic force microscope cantilevers have been investigated for their use as the encoder for real-time high-resolution displacement measurements, when paired with a 1D sinusoidal grating of well-known pitch. For a known one-directional (forward or backward) displacement measurement, the decoding algorithm is based on directly counting the integer periods of the grating and calculating the fractional parts at the beginning of the displacement and at the actual position by using one cantilever. Using two cantilevers arranged in the quadrature phase shift positions on the grating makes the measurement of two-directional (forward and backward) displacements possible. The decoding algorithm directly unwraps the phase between two encoded signals. Cross-correlation filtering and the differentiation process of two encoded signals are found to be very successful to guarantee the implementation of real-time displacement measurements by suppressing noise and reducing the offset and tilt of the encoded signals.

[1]  Kamal Youcef-Toumi,et al.  Real-time subnanometer position sensing with long measurement range , 1995, Proceedings of 1995 IEEE International Conference on Robotics and Automation.

[2]  Gwo-Sheng Peng,et al.  Correction of nonlinearity in one-frequency optical interferometry , 1996 .

[3]  Chien‐Ming Wu,et al.  Nonlinearity in measurements of length by optical interferometry , 1996 .

[4]  L Cai,et al.  Autofocus laser rotary encoder. , 1998, Applied optics.

[5]  Kyuwon Jeong,et al.  The dynamic compensation of nonlinearity in a homodyne laser interferometer , 2001 .

[6]  Sheng-Hua Lu,et al.  High resolution planar encoder by retro-reflection , 2005 .

[7]  Ludger Koenders,et al.  Verfahren und Vorrichtung zur Bestimmung einer Winkelteilung , 2006 .

[8]  Hiroshi Honda,et al.  Two-dimensional encoder with picometre resolution using lattice spacing on regular crystalline surface as standard , 2007 .

[9]  Luis Miguel Sanchez-Brea,et al.  Metrological errors in optical encoders , 2008 .

[10]  Janez Mozina,et al.  Quadrature phase-shift error analysis using a homodyne laser interferometer. , 2009, Optics express.

[11]  Eiki Okuyama,et al.  A two-dimensional atom encoder using one lateral-dithered scanning tunneling microscope (STM) tip and a regular crystalline lattice , 2009 .

[12]  Tae Bong Eom,et al.  A digital signal processing module for real-time compensation of nonlinearity in a homodyne interferometer using a field-programmable gate array , 2009 .

[13]  G. Lerondel,et al.  Quasi-common-optical-path heterodyne grating interferometer for displacement measurement , 2010 .

[14]  Ludger Koenders,et al.  Atomic force microscope cantilever as an encoding sensor for real-time displacement measurement , 2010 .

[15]  Frank Härtig,et al.  Real-time cross-correlation filtering of a one-dimensional grating position-encoded signal , 2011 .