Passive Thermographic Inspection of Adhered Ceramic Claddings: Limitation and Conditioning Factors

AbstractAdhered ceramic tiles are one of the most commonly used exterior cladding materials in Portugal. However, various durability problems are also noted by the researchers. A research study was therefore designed to identify in situ inspection techniques that can be used for detecting moisture-content increase and delamination problems of this type of cladding, and for this purpose 16 buildings in Lisbon were inspected by infrared (IR) thermography. In IR thermography, various factors affect data collection and interpretation and this may lead to false or questionable indications. Factors of this nature observed during the in situ passive thermographic inspection of these 16 buildings have been gathered and systematized to support the decision whether to use passive thermography in detecting moisture and delamination problems in an adhered ceramic cladding of a particular building, considering its characteristics. The factors observed were organized in two main groups associated with (1) the building/...

[1]  B. Pettersson,et al.  Thermography: testing of the thermal insulation and airtightness of buildings , 1980 .

[2]  X. Maldague Nondestructive Evaluation of Materials by Infrared Thermography , 1993 .

[3]  Ermanno G. Grinzato,et al.  Quantitative infrared thermography in buildings , 1998 .

[4]  Michael Yit Lin Chew Assessing building façades using infra‐red thermography , 1998 .

[5]  Elisabetta Rosina,et al.  Optimal thermographic procedures for moisture analysis in building materials , 1999, Industrial Lasers and Inspection.

[6]  Constantinos A. Balaras,et al.  Infrared thermography for building diagnostics , 2002 .

[7]  Elisabetta Rosina,et al.  Applying Infrared Thermography to Historic Wood-Framed Buildings in North America , 2002 .

[8]  Ermanno G. Grinzato,et al.  Monitoring of ancient buildings by the thermal method , 2002 .

[9]  Michael Forde,et al.  Application of infrared thermography to the non-destructive testing of concrete and masonry bridges , 2003 .

[10]  Elisabetta Rosina,et al.  Using Infrared Thermography to Detect Moisture in Historic Masonry: A Case Study in Indiana , 2003 .

[11]  Giovanni Maria Carlomagno,et al.  REVIEW ARICLE: Recent advances in the use of infrared thermography , 2004 .

[12]  Tommy Y. Lo,et al.  Building defects diagnosis by infrared thermography , 2004 .

[13]  S. Marinetti,et al.  Thermal NdE of FRP applied to civil structures , 2006 .

[14]  Bernd Hillemeier,et al.  Application of impulse-thermography for non-destructive assessment of concrete structures , 2006 .

[15]  E. Barreira,et al.  Evaluation of building materials using infrared thermography , 2007 .

[16]  Y. Y. Hung,et al.  Review and comparison of shearography and active thermography for nondestructive evaluation , 2009 .

[17]  Byron Burlingame,et al.  ASTM F1518—00 Standard Practice for Cleaning and Disinfection of Flexible Fiberoptic and Video Endo scopes Used in the Examination of the Hollow Viscera. West Conshohocken, PA: ASTM International; 2000:663. , 2009 .

[18]  José Dinis Silvestre,et al.  Ceramic tiling inspection system , 2009 .

[19]  Michael Vollmer,et al.  Infrared Thermal Imaging: Fundamentals, Research and Applications , 2010 .

[20]  Ralf Arndt,et al.  Square pulse thermography in frequency domain as adaptation of pulsed phase thermography for qualitative and quantitative applications in cultural heritage and civil engineering , 2010 .

[21]  J. L. Lerma,et al.  Multitemporal thermal analysis to detect moisture on a building façade , 2011 .