Assessment of reduced-order unscented Kalman filter for parameter identification in 1-dimensional blood flow models using experimental data.

This work presents a detailed investigation of a parameter estimation approach on the basis of the reduced-order unscented Kalman filter (ROUKF) in the context of 1-dimensional blood flow models. In particular, the main aims of this study are (1) to investigate the effects of using real measurements versus synthetic data for the estimation procedure (i.e., numerical results of the same in silico model, perturbed with noise) and (2) to identify potential difficulties and limitations of the approach in clinically realistic applications to assess the applicability of the filter to such setups. For these purposes, the present numerical study is based on a recently published in vitro model of the arterial network, for which experimental flow and pressure measurements are available at few selected locations. To mimic clinically relevant situations, we focus on the estimation of terminal resistances and arterial wall parameters related to vessel mechanics (Young's modulus and wall thickness) using few experimental observations (at most a single pressure or flow measurement per vessel). In all cases, we first perform a theoretical identifiability analysis on the basis of the generalized sensitivity function, comparing then the results owith the ROUKF, using either synthetic or experimental data, to results obtained using reference parameters and to available measurements.

[1]  P. Tallec,et al.  Joint state and parameter estimation for distributed mechanical systems , 2008 .

[2]  R. Himeno,et al.  Biomechanical characterization of ventricular-arterial coupling during aging: a multi-scale model study. , 2009, Journal of biomechanics.

[3]  R. E. Kalman,et al.  New Results in Linear Filtering and Prediction Theory , 1961 .

[4]  Lucas O. Müller,et al.  Hyperbolic reformulation of a 1D viscoelastic blood flow model and ADER finite volume schemes , 2014, J. Comput. Phys..

[5]  Peng Zhao,et al.  Blood Flow in the Circle of Willis: Modeling and Calibration , 2008, Multiscale Model. Simul..

[6]  D. Lombardi Inverse problems in 1D hemodynamics on systemic networks: A sequential approach , 2014, International journal for numerical methods in biomedical engineering.

[7]  Marcel C M Rutten,et al.  Experimental validation of a time-domain-based wave propagation model of blood flow in viscoelastic vessels. , 2008, Journal of biomechanics.

[8]  Pedro A. Lemos,et al.  An Anatomically Detailed Arterial Network Model for One-Dimensional Computational Hemodynamics , 2015, IEEE Transactions on Biomedical Engineering.

[9]  E. Haacke,et al.  Impact of CCSVI on cerebral haemodynamics: a mathematical study using MRI angiographic and flow data , 2016, Phlebology.

[10]  F. Liang,et al.  A computational model study of the influence of the anatomy of the circle of willis on cerebral hyperperfusion following carotid artery surgery , 2011, Biomedical engineering online.

[11]  D. Chapelle,et al.  Reduced-order Unscented Kalman Filtering with application to parameter identification in large-dimensional systems , 2011 .

[12]  Lucas O Müller,et al.  A global multiscale mathematical model for the human circulation with emphasis on the venous system , 2014, International journal for numerical methods in biomedical engineering.

[13]  J. Mynard,et al.  One-Dimensional Haemodynamic Modeling and Wave Dynamics in the Entire Adult Circulation , 2015, Annals of Biomedical Engineering.

[14]  Claudio Cobelli,et al.  Generalized Sensitivity Functions in Physiological System Identification , 1999, Annals of Biomedical Engineering.

[15]  J-F Gerbeau,et al.  A methodological paradigm for patient‐specific multi‐scale CFD simulations: from clinical measurements to parameter estimates for individual analysis , 2014, International journal for numerical methods in biomedical engineering.

[16]  Simon J. Julier,et al.  The spherical simplex unscented transformation , 2003, Proceedings of the 2003 American Control Conference, 2003..

[17]  S. Sherwin,et al.  Pulse wave propagation in a model human arterial network: Assessment of 1-D visco-elastic simulations against in vitro measurements , 2011, Journal of biomechanics.

[18]  S. Sherwin,et al.  Modelling the circle of Willis to assess the effects of anatomical variations and occlusions on cerebral flows. , 2007, Journal of biomechanics.

[19]  N. Stergiopulos,et al.  Validation of a one-dimensional model of the systemic arterial tree. , 2009, American journal of physiology. Heart and circulatory physiology.

[20]  Jeffrey K. Uhlmann,et al.  Unscented filtering and nonlinear estimation , 2004, Proceedings of the IEEE.

[21]  P Segers,et al.  Experimental validation of a pulse wave propagation model for predicting hemodynamics after vascular access surgery. , 2012, Journal of biomechanics.

[22]  Lucas O. Müller,et al.  A benchmark study of numerical schemes for one‐dimensional arterial blood flow modelling , 2015, International journal for numerical methods in biomedical engineering.

[23]  Pablo J. Blanco,et al.  A high‐order local time stepping finite volume solver for one‐dimensional blood flow simulations: application to the ADAN model , 2016, International journal for numerical methods in biomedical engineering.

[24]  M. Olufsen,et al.  Numerical Simulation and Experimental Validation of Blood Flow in Arteries with Structured-Tree Outflow Conditions , 2000, Annals of Biomedical Engineering.

[25]  F. Lazeyras,et al.  Validation of a patient-specific one-dimensional model of the systemic arterial tree. , 2011, American journal of physiology. Heart and circulatory physiology.

[26]  P. Moireau,et al.  Sequential parameter estimation for fluid–structure problems: Application to hemodynamics , 2012, International journal for numerical methods in biomedical engineering.

[27]  C D Murray,et al.  The Physiological Principle of Minimum Work: I. The Vascular System and the Cost of Blood Volume. , 1926, Proceedings of the National Academy of Sciences of the United States of America.

[28]  Lucas O. Müller,et al.  Well‐balanced high‐order solver for blood flow in networks of vessels with variable properties , 2013, International journal for numerical methods in biomedical engineering.

[29]  Pablo J Blanco,et al.  Blood flow distribution in an anatomically detailed arterial network model: criteria and algorithms , 2014, Biomechanics and modeling in mechanobiology.

[30]  W Huberts,et al.  A pulse wave propagation model to support decision-making in vascular access planning in the clinic. , 2012, Medical engineering & physics.