Continuous EEG source imaging enhances analysis of EEG-fMRI in focal epilepsy

INTRODUCTION EEG-correlated fMRI (EEG-fMRI) studies can reveal haemodynamic changes associated with Interictal Epileptic Discharges (IED). Methodological improvements are needed to increase sensitivity and specificity for localising the epileptogenic zone. We investigated whether the estimated EEG source activity improved models of the BOLD changes in EEG-fMRI data, compared to conventional << event-related >> designs based solely on the visual identification of IED. METHODS Ten patients with pharmaco-resistant focal epilepsy underwent EEG-fMRI. EEG Source Imaging (ESI) was performed on intra-fMRI averaged IED to identify the irritative zone. The continuous activity of this estimated IED source (cESI) over the entire recording was used for fMRI analysis (cESI model). The maps of BOLD signal changes explained by cESI were compared to results of the conventional IED-related model. RESULTS ESI was concordant with non-invasive data in 13/15 different types of IED. The cESI model explained significant additional BOLD variance in regions concordant with video-EEG, structural MRI or, when available, intracranial EEG in 10/15 IED. The cESI model allowed better detection of the BOLD cluster, concordant with intracranial EEG in 4/7 IED, compared to the IED model. In 4 IED types, cESI-related BOLD signal changes were diffuse with a pattern suggestive of contamination of the source signal by artefacts, notably incompletely corrected motion and pulse artefact. In one IED type, there was no significant BOLD change with either model. CONCLUSION Continuous EEG source imaging can improve the modelling of BOLD changes related to interictal epileptic activity and this may enhance the localisation of the irritative zone.

[1]  Thomas Dierks,et al.  BOLD correlates of continuously fluctuating epileptic activity isolated by independent component analysis , 2008, NeuroImage.

[2]  Jean Gotman,et al.  Hemodynamic changes preceding the interictal EEG spike in patients with focal epilepsy investigated using simultaneous EEG-fMRI , 2009, NeuroImage.

[3]  Matthew J. Brookes,et al.  Simultaneous EEG source localisation and artifact rejection during concurrent fMRI by means of spatial filtering , 2008, NeuroImage.

[4]  M. Walker,et al.  Noncanonical spike‐related BOLD responses in focal epilepsy , 2007, Human brain mapping.

[5]  M. Castelo‐Branco,et al.  ICA decomposition of EEG signal for fMRI processing in epilepsy , 2009, Human brain mapping.

[6]  Jeff H. Duyn,et al.  Low-frequency fluctuations in the cardiac rate as a source of variance in the resting-state fMRI BOLD signal , 2007, NeuroImage.

[7]  Kazuki Iwata,et al.  Artifact reduction for EEG/fMRI recording: Nonlinear reductionof ballistocardiogram artifacts , 2006, Clinical Neurophysiology.

[8]  Jean Gotman,et al.  EEG–fMRI of epileptic spikes: Concordance with EEG source localization and intracranial EEG , 2006, NeuroImage.

[9]  M. Sillanpää Long-term outcome of epilepsy. , 2000, Epileptic disorders : international epilepsy journal with videotape.

[10]  Christoph M. Michel,et al.  Combination of EEG–fMRI and EEG source analysis improves interpretation of spike-associated activation networks in paediatric pharmacoresistant focal epilepsies , 2009, NeuroImage.

[11]  J. Gotman,et al.  fMRI Activation in Continuous and Spike‐triggered EEG–fMRI Studies of Epileptic Spikes , 2003, Epilepsia.

[12]  Jean Gotman,et al.  Analysis of the EEG–fMRI response to prolonged bursts of interictal epileptiform activity , 2005, NeuroImage.

[13]  A. Kleinschmidt,et al.  Electroencephalographic signatures of attentional and cognitive default modes in spontaneous brain activity fluctuations at rest , 2003, Proceedings of the National Academy of Sciences of the United States of America.

[14]  Karl J. Friston,et al.  Movement‐Related effects in fMRI time‐series , 1996, Magnetic resonance in medicine.

[15]  L. Lemieux,et al.  Modelling large motion events in fMRI studies of patients with epilepsy. , 2007, Magnetic resonance imaging.

[16]  Robert Turner,et al.  A Method for Removing Imaging Artifact from Continuous EEG Recorded during Functional MRI , 2000, NeuroImage.

[17]  Karl J. Friston,et al.  EEG–fMRI of idiopathic and secondarily generalized epilepsies , 2006, NeuroImage.

[18]  C. N. Guy,et al.  Intracerebral propagation of interictal activity in partial epilepsy: implications for source localisation. , 1994, Journal of neurology, neurosurgery, and psychiatry.

[19]  Yingli Lu,et al.  BOLD changes occur prior to epileptic spikes seen on scalp EEG , 2007, NeuroImage.

[20]  S. Spencer,et al.  Nontumoral occipitotemporal epilepsy: Localizing findings and surgical outcome , 1999, Annals of neurology.

[21]  G L Shulman,et al.  INAUGURAL ARTICLE by a Recently Elected Academy Member:A default mode of brain function , 2001 .

[22]  C. Michel,et al.  Noninvasive Localization of Electromagnetic Epileptic Activity. I. Method Descriptions and Simulations , 2004, Brain Topography.

[23]  M. Murray,et al.  EEG source imaging , 2004, Clinical Neurophysiology.

[24]  Peter A. Bandettini,et al.  Separating respiratory-variation-related fluctuations from neuronal-activity-related fluctuations in fMRI , 2006, NeuroImage.

[25]  C. Michel,et al.  Propagation of Interictal Epileptiform Activity Can Lead to Erroneous Source Localizations: A 128-Channel EEG Mapping Study , 2003, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[26]  J. Gotman,et al.  Cortical and thalamic fMRI responses in partial epilepsy with focal and bilateral synchronous spikes , 2006, Clinical Neurophysiology.

[27]  Karl J. Friston,et al.  Modelling cardiac signal as a confound in EEG-fMRI and its application in focal epilepsy studies , 2006, NeuroImage.

[28]  C. Michel,et al.  Noninvasive Localization of Electromagnetic Epileptic Activity. II. Demonstration of Sublobar Accuracy in Patients with Simultaneous Surface and Depth Recordings , 2004, Brain Topography.

[29]  Louis Lemieux,et al.  Identification of EEG Events in the MR Scanner: The Problem of Pulse Artifact and a Method for Its Subtraction , 1998, NeuroImage.

[30]  M R Symms,et al.  EEG-triggered functional MRI of interictal epileptiform activity in patients with partial seizures. , 1999, Brain : a journal of neurology.

[31]  J. Ebersole,et al.  Intracranial EEG Substrates of Scalp EEG Interictal Spikes , 2005, Epilepsia.

[32]  M. Corbetta,et al.  Electrophysiological signatures of resting state networks in the human brain , 2007, Proceedings of the National Academy of Sciences.

[33]  Jean Gotman,et al.  Negative BOLD responses to epileptic spikes , 2006, Human brain mapping.

[34]  Matthew J. Brookes,et al.  Source localisation in concurrent EEG/fMRI: Applications at 7T , 2009, NeuroImage.

[35]  Karl J. Friston,et al.  Causal Hierarchy within the Thalamo-Cortical Network in Spike and Wave Discharges , 2009, PloS one.

[36]  Karl J. Friston,et al.  Hemodynamic correlates of epileptiform discharges: An EEG-fMRI study of 63 patients with focal epilepsy , 2006, Brain Research.

[37]  John S. Duncan,et al.  Analysis of EEG–fMRI data in focal epilepsy based on automated spike classification and Signal Space Projection , 2006, NeuroImage.

[38]  John S. Duncan,et al.  Independent component analysis of interictal fMRI in focal epilepsy: Comparison with general linear model-based EEG-correlated fMRI , 2007, NeuroImage.

[39]  A. Kleinschmidt,et al.  Temporal lobe interictal epileptic discharges affect cerebral activity in “default mode” brain regions , 2006, Human brain mapping.

[40]  C. Michel,et al.  Electromagnetic Inverse Solutions in Anatomically Constrained Spherical Head Models , 2004, Brain Topography.

[41]  Christoph M. Michel,et al.  The spatio-temporal mapping of epileptic networks: Combination of EEG–fMRI and EEG source imaging , 2009, NeuroImage.

[42]  J. Gotman,et al.  Temporal and Extratemporal BOLD Responses to Temporal Lobe Interictal Spikes , 2006, Epilepsia.