Disturbance-Observer Assisted Controller for Stand-Alone Four-Leg Voltage Source Inverter

In this paper, a newly disturbance-observer based control strategy for stand-alone four-leg VSI has been proposed and analyzed. The disturbance-observer operates together with a simple and effective resonant controller in order to regulate the inverter output voltage. In particular, the resonant controller regulates the output voltage fundamental harmonic, whereas the disturbance observer is designed for compensating output voltage harmonics when non-linear loads have to be fed. The new control strategy effectiveness and performance have been validated at first through a full MATLAB/Simulink model and then by experimental results on a dedicated 40 kVA three-phase 4-leg.

[1]  Dinkar Prasad,et al.  A Modified Feedback Scheme Suitable for Repetitive Control of Inverter With Nonlinear Load , 2018, IEEE Transactions on Power Electronics.

[2]  Saad Mekhilef,et al.  Digital predictive current control of multi-level four-leg voltage-source inverter under balanced and unbalanced load conditions , 2017 .

[3]  Francisco D. Freijedo,et al.  Analysis and Design of Resonant Current Controllers for Voltage-Source Converters by Means of Nyquist Diagrams and Sensitivity Function , 2011, IEEE Transactions on Industrial Electronics.

[4]  Luca Solero,et al.  Towards LabVIEW and system on module for power electronics and drives control applications , 2016, IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society.

[5]  Pericle Zanchetta,et al.  Resonant-repetitive combined control for stand-alone power supply units , 2014, 2014 IEEE Energy Conversion Congress and Exposition (ECCE).

[6]  T. Senjyu,et al.  Robust current control method with disturbance voltage observer for voltage source PWM inverter , 1995, Proceedings of 1995 International Conference on Power Electronics and Drive Systems. PEDS 95.

[7]  Xinbo Ruan,et al.  Neutral Point Voltage Ripple Suppression for a Three-Phase Four-Wire Inverter With an Independently Controlled Neutral Module , 2017, IEEE Transactions on Industrial Electronics.

[8]  Stefano Bifaretti,et al.  Resonant Controllers With Three Degrees of Freedom for AC Power Electronic Converters , 2015, IEEE Transactions on Industry Applications.

[9]  Luca Solero,et al.  LC Filter Design for On-Grid and Off-Grid Distributed Generating Units , 2015, IEEE Transactions on Industry Applications.

[10]  Karim Hassan Youssef Power Quality Constrained Optimal Management of Unbalanced Smart Microgrids During Scheduled Multiple Transitions Between Grid-Connected and Islanded Modes , 2017, IEEE Transactions on Smart Grid.

[11]  Keliang Zhou,et al.  Plug-In Dual-Mode-Structure Repetitive Controller for CVCF PWM Inverters , 2009, IEEE Transactions on Industrial Electronics.

[12]  Pericle Zanchetta,et al.  Design of a repetitive controller as a feed-forward disturbance observer , 2016, IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society.

[13]  Jano Malvar,et al.  Effects of Discretization Methods on the Performance of Resonant Controllers , 2010, IEEE Transactions on Power Electronics.