Postacquisition Detection of Tumor Motion in the Lung and Upper Abdomen Using List-Mode PET Data: A Feasibility Study
暂无分享,去创建一个
S. Nekolla | M. Schwaiger | S. Ziegler | R. Bundschuh | A. Martínez-Moeller | M. Essler | María-José Martínez | María-José Martínez
[1] A. Savitzky,et al. Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .
[2] H. Kubo,et al. Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.
[3] G. J. Klein,et al. Real-time system for respiratory-cardiac gating in positron tomography , 1997 .
[4] C. C. Watson,et al. New, faster, image-based scatter correction for 3D PET , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).
[5] R. Huesman,et al. Fine-scale motion detection using intrinsic list mode PET information , 2001, Proceedings IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA 2001).
[6] R K Ten Haken,et al. The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.
[7] C. Ling,et al. Effect of respiratory gating on quantifying PET images of lung cancer. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[8] M. V. van Herk,et al. Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.
[9] Cyrill Burger,et al. Accuracy of image coregistration of pulmonary lesions in patients with non-small cell lung cancer using an integrated PET/CT system. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[10] P.M. Bloomfield,et al. Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET , 2005, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).
[11] Roger Fulton,et al. The design and implementation of a motion correction scheme for neurological PET. , 2003, Physics in medicine and biology.
[12] Cyrill Burger,et al. Respiration-induced attenuation artifact at PET/CT: technical considerations. , 2003, Radiology.
[13] D. Visvikis,et al. A posteriori respiratory motion gating of dynamic PET images , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).
[14] Jeffrey D Bradley,et al. Implementing biologic target volumes in radiation treatment planning for non-small cell lung cancer. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.
[15] Hans-Ulrich Kauczor,et al. Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. , 2004, International journal of radiation oncology, biology, physics.
[16] O. Schober,et al. Motion correction in PET/CT , 2005, Nuklearmedizin.
[17] George T. Y. Chen,et al. Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.
[18] S. Rafla,et al. The contribution of integrated PET/CT to the evolving definition of treatment volumes in radiation treatment planning in lung cancer. , 2005, International journal of radiation oncology, biology, physics.
[19] Suresh Senan,et al. Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets. , 2005, International journal of radiation oncology, biology, physics.
[20] M Schwaiger,et al. PET/CT Biograph Sensation 16. Performance improvement using faster electronics. , 2006, Nuklearmedizin. Nuclear medicine.