Postacquisition Detection of Tumor Motion in the Lung and Upper Abdomen Using List-Mode PET Data: A Feasibility Study

One of the main degrading factors in the quality of oncologic PET images of the thorax and upper abdomen is respiratory motion of tumors. One method to reduce this effect is the acquisition of PET data in gated mode. A second method is the correction of studies for motion. Motion registration is essential in both cases. We report a method using list-mode data to detect the craniocaudal (z) movement of thoracic and abdominal lesions without using any external gating device. The aim of this study was to show the feasibility of applying this method to patient data. Methods: For 10 patients with lesions in the lung or upper abdominal organs, images for short time bins of 250, 500, and 750 ms were reconstructed. A volume of interest, which was manually defined in a summed image around the structure of interest, was projected to each time bin. The center of mass of the activity distribution in this volume of interest was determined for each case. The curves of the z-coordinate of the center of mass (zCOM) over the time were analyzed and compared with respiration curves obtained by a pressure-sensitive belt. Results: In 7 of the 10 patients, movement of the lesion was registered in good accordance with the pressure belt. In the 3 remaining patients, no changes in the center of mass due to respiration could be detected, most likely because of minimal respiratory motion. The maximal difference in zCOM for a lesion that was detected within the 10-min acquisition was 18.5 mm. For 7 of the 10 patients, the mean value for each respiration amplitude was between 11.0 and 2.0 mm. Conclusion: We have shown the feasibility of registering movement of high-uptake lesions without the use of any external device that may restrain the patient. Furthermore, unlike external sensors, this method quantifies internal motion and, thus, is a promising base for correction methods.

[1]  A. Savitzky,et al.  Smoothing and Differentiation of Data by Simplified Least Squares Procedures. , 1964 .

[2]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[3]  G. J. Klein,et al.  Real-time system for respiratory-cardiac gating in positron tomography , 1997 .

[4]  C. C. Watson,et al.  New, faster, image-based scatter correction for 3D PET , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[5]  R. Huesman,et al.  Fine-scale motion detection using intrinsic list mode PET information , 2001, Proceedings IEEE Workshop on Mathematical Methods in Biomedical Image Analysis (MMBIA 2001).

[6]  R K Ten Haken,et al.  The reproducibility of organ position using active breathing control (ABC) during liver radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[7]  C. Ling,et al.  Effect of respiratory gating on quantifying PET images of lung cancer. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[8]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[9]  Cyrill Burger,et al.  Accuracy of image coregistration of pulmonary lesions in patients with non-small cell lung cancer using an integrated PET/CT system. , 2002, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[10]  P.M. Bloomfield,et al.  Rigid-body transformation of list-mode projection data for respiratory motion correction in cardiac PET , 2005, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[11]  Roger Fulton,et al.  The design and implementation of a motion correction scheme for neurological PET. , 2003, Physics in medicine and biology.

[12]  Cyrill Burger,et al.  Respiration-induced attenuation artifact at PET/CT: technical considerations. , 2003, Radiology.

[13]  D. Visvikis,et al.  A posteriori respiratory motion gating of dynamic PET images , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[14]  Jeffrey D Bradley,et al.  Implementing biologic target volumes in radiation treatment planning for non-small cell lung cancer. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[15]  Hans-Ulrich Kauczor,et al.  Analysis of intrathoracic tumor mobility during whole breathing cycle by dynamic MRI. , 2004, International journal of radiation oncology, biology, physics.

[16]  O. Schober,et al.  Motion correction in PET/CT , 2005, Nuklearmedizin.

[17]  George T. Y. Chen,et al.  Four-dimensional image-based treatment planning: Target volume segmentation and dose calculation in the presence of respiratory motion. , 2005, International journal of radiation oncology, biology, physics.

[18]  S. Rafla,et al.  The contribution of integrated PET/CT to the evolving definition of treatment volumes in radiation treatment planning in lung cancer. , 2005, International journal of radiation oncology, biology, physics.

[19]  Suresh Senan,et al.  Benefit of respiration-gated stereotactic radiotherapy for stage I lung cancer: an analysis of 4DCT datasets. , 2005, International journal of radiation oncology, biology, physics.

[20]  M Schwaiger,et al.  PET/CT Biograph Sensation 16. Performance improvement using faster electronics. , 2006, Nuklearmedizin. Nuclear medicine.