Full-Scale Validation of Dynamic Wind Load on a Super-Tall Building under Strong Wind

AbstractThis paper presents work on validating the dynamic wind load predicted by a wind tunnel model with the values identified from full-scale field vibration data of a super-tall building in Hong Kong. Dynamic wind load in this work refers to the power spectral density (PSD) of the modal force near the natural frequency of a particular mode of the building, in the context of random vibration with stationary loading and response. This quantity reflects the turbulence characteristics integrated over the building body and is of importance in wind engineering design. This study presents a method to predict the modal PSD of wind load of the first two translational modes of a tall building. The method combines wind tunnel test information and mean wind data available in the free field; the latter taken to be at the Waglan Island station maintained by the Hong Kong Observatory. On the full-scale side, although the modal PSD is not directly observable, it is identified from field vibration data measured at the...

[1]  Siu-Kui Au,et al.  Field observations on modal properties of two tall buildings under strong wind , 2012 .

[2]  N. Isyumov,et al.  Some full-scale measurements of wind-induced response of the CN Tower, Toronto☆ , 1975 .

[3]  Siu-Kui Au,et al.  Ambient modal identification of a primary-secondary structure by Fast Bayesian FFT method , 2012 .

[4]  James M. W. Brownjohn,et al.  Ambient vibration studies for system identification of tall buildings , 2003 .

[5]  J. Beck Bayesian system identification based on probability logic , 2010 .

[6]  B. Peeters,et al.  Stochastic System Identification for Operational Modal Analysis: A Review , 2001 .

[7]  J. Peterka,et al.  Aerodynamic Model Tests of Tall Buildings , 1989 .

[8]  S. Au Fast Bayesian ambient modal identification in the frequency domain, Part I: Posterior most probable value , 2012 .

[9]  Siu-Kui Au,et al.  Full-scale dynamic testing and modal identification of a coupled floor slab system , 2012 .

[10]  Alan G. Davenport,et al.  The base balance technique for the determination of dynamic wind loads , 1983 .

[11]  Yukio Tamura,et al.  Damping Evaluation Using Full-Scale Data of Buildings in Japan , 2003 .

[12]  J. B Frandsen,et al.  Simultaneous pressures and accelerations measured full-scale on the Great Belt East suspension bridge , 2001 .

[13]  Shahram Sarkani,et al.  Random Vibrations: Analysis of Structural and Mechanical Systems , 2003 .

[14]  Ahsan Kareem,et al.  Experimental Verification and Full-Scale Deployment of Global Positioning Systems to Monitor the Dynamic Response of Tall Buildings , 2006 .

[15]  Siu-Kui Au,et al.  Fast Bayesian FFT Method for Ambient Modal Identification with Separated Modes , 2011 .

[16]  S. Au Fast Bayesian ambient modal identification in the frequency domain, Part II: Posterior uncertainty , 2012 .

[17]  Ahsan Kareem,et al.  Validating wind-induced response of tall buildings : Synopsis of the chicago full-scale monitoring program , 2006 .

[18]  Chris Letchford,et al.  International Comparison of Wind Tunnel Estimates of Wind Effects on Low-Rise Buildings: Test-Related Uncertainties , 2008 .

[19]  Yukio Tamura,et al.  Long-term monitoring of wind-induced responses of a large-span roof structure , 2011 .

[20]  R. Clough,et al.  Dynamics Of Structures , 1975 .

[21]  Jack Edward Cermak Wind-Simulation Criteria for Wind-Effect Tests , 1984 .

[22]  S. Mousset The international Aylesbury collaborative experiment in C.S.T.B. , 1986 .

[23]  Lambros S. Katafygiotis,et al.  Bayesian Fast Fourier Transform Approach for Modal Updating Using Ambient Data , 2003 .