Emissions of Ammonia, Hydrogen Sulfide, and Odor before, during, and after Slurry Removal from a Deep-Pit Swine Finisher

Abstract It is a common practice in the midwestern United States to raise swine in buildings with under-floor slurry storage systems designed to store manure for up to one year. These so-called “deep-pit” systems are a concentrated source for the emissions of ammonia (NH3), hydrogen sulfide (H2S), and odors. As part of a larger six-state research effort (U.S. Department of Agriculture-Initiative for Future Agriculture and Food Systems Project, “Aerial Pollutant Emissions from Confined Animal Buildings”), real-time NH3 and H2S with incremental odor emission data were collected for two annual slurry removal events. For this study, two 1000-head deep-pit swine finishing facilities in central Iowa were monitored with one-year storage of slurry maintained in a 2.4 m-deep concrete pit (or holding tank) below the animal-occupied zone. Results show that the H2S emission, measured during four independent slurry removal events over two years, increased by an average of 61.9 times relative to the before-removal H2S emission levels. This increase persisted during the agitation process of the slurry that on average occurred over an 8-hr time period. At the conclusion of slurry agitation, the H2S emission decreased by an average of 10.4 times the before-removal emission level. NH3 emission during agitation increased by an average of 4.6 times the before-removal emission level and increased by an average of 1.5 times the before-removal emission level after slurry removal was completed. Odor emission increased by a factor of 3.4 times the before-removal odor emission level and decreased after the slurry-removal event by a factor of 5.6 times the before-removal emission level. The results indicate that maintaining an adequate barn ventilation rate regardless of animal comfort demand is essential to keeping gas levels inside the barn below hazardous levels.

[1]  D. H. O'Neill,et al.  A review of the control of odour nuisance from livestock buildings: Part 3, properties of the odorous substances which have been identified in livestock wastes or in the air around them , 1992 .

[2]  Theo Demmers,et al.  Ammonia emissions from two mechanically ventilated UK livestock buildings , 1999 .

[3]  Albert J. Heber,et al.  SE—Structures and Environment , 2000 .

[4]  J. Hartung,et al.  Concentrations and emissions of ammonia in livestock buildings in Northern Europe , 1998 .

[5]  H. Xin,et al.  Ammonia Emissions from Broiler Houses in Kentucky during Winter , 2003 .

[6]  T. Hinz,et al.  A comprehensive experimental study of aerial pollutants in and emissions from livestock buildings. Part 1 : Methods , 1998 .

[7]  D. Burton,et al.  Nitrogen losses from swine housings , 1986 .

[8]  Steven J. Hoff,et al.  Emissions and Community Exposures from CAFOs , 2002 .

[9]  Steven J. Hoff,et al.  Quality assured measurements of animal building emissions , 2006 .

[10]  Steven J. Hoff,et al.  Quality-Assured Measurements of Animal Building Emissions: Particulate Matter Concentrations , 2006, Journal of the Air & Waste Management Association.

[11]  A.J.A. Aarnink,et al.  Ammonia Emission Patterns during the Growing Periods of Pigs Housed on Partially Slatted Floors , 1995 .

[12]  Jun Zhu,et al.  Daily variations in odor and gas emissions from animal facilities. , 2000 .

[13]  Albert J. Heber,et al.  Quality Assured Measurements of Animal Building Emissions : Part 1-Gas Concentrations , 2004 .

[14]  J. Hatfield,et al.  Functional classification of swine manure management systems based on effluent and gas emission characteristics. , 2001, Journal of environmental quality.

[15]  Hans Benny Rom,et al.  CONTINUOUS MEASUREMENT OF NITROUS OXIDE AND METHANE EMISSION IN PIG UNITS BY INFRARED PHOTOACOUSTIC DETECTION , 1998 .