The microcirculation image quality score: development and preliminary evaluation of a proposed approach to grading quality of image acquisition for bedside videomicroscopy.

PURPOSE Side-stream dark-field microscopy is currently used to directly visualize sublingual microcirculation at the bedside. Our experience has found inherent technical challenges in the image acquisition process. This article presents and assesses a quality assurance method to rate image acquisition quality before analysis. MATERIALS AND METHODS We identified 6 common image capture and analysis problem areas in sublingual side-stream dark-field videos: illumination, duration, focus, content, stability, and pressure. We created the "Microcirculation Image Quality Score" by assigning a score of optimal (0 points), suboptimal but acceptable (1 point), or unacceptable (10 points) to each category (for further details, go to http://www.MicroscanAnalysis.blogspot.com). We evaluated 59 videos from a convenience sample of 34 unselected, noncritically ill emergency department patients to create a test set. Two raters, blinded to each other, implemented the score. Any video with a cumulative score of 10 or higher (range, 0-60) was considered unacceptable for further analysis. RESULTS We created the Microcirculation Image Quality Score and applied it to 59 videos. For this particular set of 59 videos, the mean (SD) passing quality score was 1.68 (0.90), and the mean (SD) failing quality score was 15.74 (6.19), with 27 of 59 passing the quality score less than 10. Highest failure occurred from pressure artifact. The interrater agreement for acceptability was assessed using Cohen κ for each category: illumination (κ = 1.0), duration (κ = 1.0), focus (κ = 0.91), content (κ = 0.76), stability (κ = 0.71), and pressure (κ = 0.82) and overall pass-fail rates (score >10) (κ = 0.66). CONCLUSION Our Microcirculation Image Quality Score addresses many of the common areas where video quality can degrade. The criteria introduced are an objective way to assess the quality of image acquisition, with the goal of selecting videos of adequate quality for analysis. The interrater reliability results in our preliminary study suggest that the Microcirculation Image Quality Score is reasonably repeatable between reviewers. Further assessment is warranted.

[1]  C. Ince,et al.  Sidestream Dark Field (SDF) imaging: a novel stroboscopic LED ring-based imaging modality for clinical assessment of the microcirculation. , 2007, Optics express.

[2]  Jean-Charles Preiser,et al.  Microvascular blood flow is altered in patients with sepsis. , 2002, American journal of respiratory and critical care medicine.

[3]  C. Ince,et al.  Normal sublingual microcirculation during painful crisis in sickle cell disease. , 2008, Microvascular research.

[4]  C G Ellis,et al.  Application of image analysis for evaluation of red blood cell dynamics in capillaries. , 1992, Microvascular research.

[5]  M. Simoons,et al.  Low‐dose nitroglycerin improves microcirculation in hospitalized patients with acute heart failure , 2009, European journal of heart failure.

[6]  Jasmeet Bajaj,et al.  Early microcirculatory perfusion derangements in patients with severe sepsis and septic shock: relationship to hemodynamics, oxygen transport, and survival. , 2007, Annals of emergency medicine.

[7]  Can Ince,et al.  Nitroglycerin in septic shock after intravascular volume resuscitation , 2002, The Lancet.

[8]  Can Ince,et al.  Improvement of Sidestream Dark Field Imaging with an Image Acquisition Stabilizer , 2010, BMC Medical Imaging.

[9]  C. Ellis,et al.  Evaluation of the flying spot technique as a television method for measuring red cell velocity in microvessels. , 1982, International journal of microcirculation, clinical and experimental.

[10]  Jacob Cohen A Coefficient of Agreement for Nominal Scales , 1960 .

[11]  E. Mik,et al.  Clinical microvascular monitoring: a bright future without a future? , 2009, Critical care medicine.

[12]  M. Sallisalmi,et al.  Evaluation of sublingual microcirculatory blood flow in the critically ill , 2012, Acta anaesthesiologica Scandinavica.

[13]  J. Bakker,et al.  Clinical review: Clinical imaging of the sublingual microcirculation in the critically ill - where do we stand? , 2012, Critical Care.