Application of joint time-frequency domain reflectometry for electric power cable diagnostics

The integrity of the electric power cables is vital to the safety of an entire electrical system. To ensure the health of the cables, a technique is needed for both detecting/locating defects, and predicting hard defects before they occur. The theory and limitations of the classical wiring diagnostic techniques time domain reflectometry (TDR) and frequency domain reflectometry (FDR) are discussed. This study then introduces joint time-frequency domain reflectometry (JTFDR) as a unique solution for the cable diagnostics and prognostics. By employing an interrogating incident signal and advanced post-processing of the reflected signals, JTFDR is shown to be capable of overcoming those limitations. JTFDR is experimentally proven to be successful for detecting and locating both hard and incipient defects. The prognostic capabilities of JTFDR are also demonstrated via accelerated ageing tests of an electric power cable. By utilising the incident/reflected signal information in the time and frequency domains simultaneously, JTFDR is proven to be a more effective diagnostic technique than the classical TDR and FDR. JTFDR can also be used to monitor incipient defects and better predict hard defects before they occur.

[1]  B. Larzelere,et al.  Experience in PD site location in XLPE cables , 2000, IEEE Electrical Insulation Magazine.

[2]  Cynthia Furse,et al.  Down to the wire [aircraft wiring] , 2001 .

[3]  H Lee Willis,et al.  Aging Power Delivery Infrastructures , 2000 .

[4]  Leon Cohen,et al.  Pulse propagation in dispersive media , 2000, Proceedings of the Tenth IEEE Workshop on Statistical Signal and Array Processing (Cat. No.00TH8496).

[5]  Jong-Gwan Yook,et al.  Detection and Location of Multiple Wiring Faults via Time–Frequency-Domain Reflectometry , 2009, IEEE Transactions on Electromagnetic Compatibility.

[6]  C. Furse,et al.  The invisible fray: a critical analysis of the use of reflectometry for fray location , 2006, IEEE Sensors Journal.

[7]  Ieee Standards Board,et al.  IEEE guide for multifactor stress functional testing of electrical insulation systems , 1991 .

[8]  P. Castaldo,et al.  Condition assessment of cable insulation systems in operating nuclear power plants , 1999 .

[9]  J. R. Laghari,et al.  Effects of multistress aging (radiation, thermal, electrical) on polypropylene , 1991 .

[10]  M. Gilany,et al.  Traveling-Wave-Based Fault-Location Scheme for Multiend-Aged Underground Cable System , 2007, IEEE Transactions on Power Delivery.

[11]  Leon Cohen Wave propagation with dispersion and damping , 2004, SPIE Optics + Photonics.

[12]  G. Mazzanti,et al.  Analysis of the Combined Effects of Load Cycling, Thermal Transients, and Electrothermal Stress on Life Expectancy of High-Voltage AC Cables , 2007, IEEE Transactions on Power Delivery.

[13]  F. Aras,et al.  Aging of 154 kV underground power cable insulation under combined thermal and electrical stresses , 2007, IEEE Electrical Insulation Magazine.

[14]  A. Al-arainy,et al.  The Performance of Strippable and Bonded Screened Medium-Voltage XLPE-Insulated Cables Under Long-Term Accelerated Aging , 2007, IEEE Transactions on Power Delivery.

[15]  S.B. Dalal,et al.  Aging of distribution cables in service and its simulation in the laboratory , 2005, IEEE Transactions on Dielectrics and Electrical Insulation.

[16]  J. P. Steiner,et al.  Recent advances in partial discharge measurement capabilities at NIST , 1992 .

[17]  M. I. Gilany,et al.  Traveling-Wave-Based Fault-Location Scheme for Multiend-Aged Underground Cable System , 2007 .

[18]  John J. Soraghan,et al.  Detection of PD utilizing digital signal processing methods. Part 3: Open-loop noise reduction , 2001 .

[19]  Yong-June Shin,et al.  Diagnostics and Prognostics of Electric Cables in Ship Power Systems via Joint Time-Frequency Domain Reflectometry , 2008, 2008 IEEE Instrumentation and Measurement Technology Conference.

[20]  Leon Cohen,et al.  A Wigner approximation method for wave propagation , 2005 .

[21]  Jin Bae Park,et al.  Application of time-frequency domain reflectometry for detection and localization of a fault on a coaxial cable , 2005, IEEE Transactions on Instrumentation and Measurement.

[22]  Yong-June Shin,et al.  Diagnostics and Prognostics of Electric Cables in Nuclear Power Plants via Joint Time-Frequency Domain Reflectometry , 2008, Conference Record of the 2008 IEEE International Symposium on Electrical Insulation.

[23]  John J. Soraghan,et al.  Digital signal processing applied to the detection of partial discharge: an overview , 2000 .

[24]  Rick Hartlein,et al.  LONG-LiFE XLPE INSULATED POWER CABLE , 2007 .

[25]  John J. Soraghan,et al.  Application of digital signal processing to the detection of partial discharge. Part 2: Optimized A/D conversion , 2000 .

[26]  J. Giacometti,et al.  Dielectric and viscoelastic properties of cross-linked polyethylene aged under multistressing conditions , 2004, IEEE Transactions on Dielectrics and Electrical Insulation.