Antibody functionalized interdigitated micro-electrode (IDmicroE) based impedimetric cortisol biosensor.

This paper reports on an ultrasensitive, disposable, impedimetric biosensor for cortisol detection. C-Mab (a Cortisol specific monoclonal antibody) was covalently immobilized via amide bond on the surface of the interdigitated micro-electrodes (IDmicroEs) functionalized with dithiobis(succinimidyl propionate) (DTSP) self-assembled monolayer (SAM). After C-Mab binding, unreacted active groups of DTSP were blocked using ethanolamine (EA) and glycine (Gly) mixture. The disposable sensors were exposed to solutions with different cortisol concentrations and a label-free electrochemical impedance (EIS) technique was used to determine the cortisol concentration. EIS results confirm that the EA-Gly/C-Mab/DTSP/IDmicroE based biosensor exhibited the sensitivity of 2.855 kohms M(-1) and could accurately detect cortisol in the range of 1 pM to 10 nM in saliva. This work establishes the feasibility of using an impedance based biosensor as a disposable cortisol detector, capable of working with complex bodily fluids (e.g., saliva). The architecture enables the use of cortisol sensors at point-of-care.

[1]  S Rosberg,et al.  Journal of Clinical Endocrinology and Metabolism Printed in U.S.A. Copyright © 1997 by The Endocrine Society Circadian Cortisol Rhythms in Healthy Boys and Girls: Relationship with Age, Growth, Body Composition, and , 2022 .

[2]  E. Alocilja,et al.  A high density microelectrode array biosensor for detection of E. coli O157:H7. , 2005, Biosensors & bioelectronics.

[3]  Shekhar Bhansali,et al.  An immunoelectrochemical sensor for salivary cortisol measurement , 2008 .

[4]  Marc Madou,et al.  DNA hybridization detection by label free versus impedance amplifying label with impedance spectroscopy , 2006 .

[5]  Steve Near,et al.  Detection of cortisol in saliva with a flow-filtered, portable surface plasmon resonance biosensor system. , 2008, Analytical chemistry.

[6]  L. Angelucci,et al.  Actual stress, psychopathology and salivary cortisol levels in the irritable bowel syndrome (IBS) , 2001, Journal of endocrinological investigation.

[7]  Camelia Bala,et al.  Biosensors based on screen-printing technology, and their applications in environmental and food analysis , 2007, Analytical and bioanalytical chemistry.

[8]  B. D. Malhotra,et al.  Dithiobissuccinimidyl propionate self assembled monolayer based cholesterol biosensor. , 2007, The Analyst.

[9]  Salvador Alegret,et al.  Integrated Analytical Systems , 2003 .

[10]  Yanbin Li,et al.  Interdigitated array microelectrodes based impedance biosensors for detection of bacterial cells. , 2009, Biosensors & bioelectronics.

[11]  Ku-Shang Chang,et al.  Application of a flow type quartz crystal microbalance immunosensor for real time determination of cattle bovine ephemeral fever virus in liquid. , 2005, Talanta.

[12]  A. Baum,et al.  Urinary Catecholamines and Cortisol in Recent-Onset Posttraumatic Stress Disorder After Motor Vehicle Accidents , 2000, Psychosomatic medicine.

[13]  F. Regnier,et al.  Capillary electrophoresis-based immunoassay for cortisol in serum. , 1995, Analytical chemistry.

[14]  E. Stigter,et al.  On the response of a label-free interferon-gamma immunosensor utilizing electrochemical impedance spectroscopy. , 2005, Biosensors & bioelectronics.

[15]  J. Mitchell,et al.  Rapid ultrasensitive measurement of salivary cortisol using nano-linker chemistry coupled with surface plasmon resonance detection. , 2009, The Analyst.

[16]  Jing C. Zhou,et al.  Immunoassays for cortisol using antibody-doped sol–gel silica , 2004 .

[17]  Eric Nebling,et al.  Electrical detection of viral DNA using ultramicroelectrode arrays. , 2004, Analytical chemistry.

[18]  R. Crooks,et al.  Immobilization of DNA onto poly(dimethylsiloxane) surfaces and application to a microelectrochemical enzyme-amplified DNA hybridization assay. , 2004, Langmuir : the ACS journal of surfaces and colloids.

[19]  E. D. De Palo,et al.  Urinary high performance reverse phase chromatography cortisol and cortisone analyses before and at the end of a race in elite cyclists. , 2005, Journal of chromatography. B, Analytical technologies in the biomedical and life sciences.

[20]  Shekhar Bhansali,et al.  Ultrasensitive detection of cortisol with enzyme fragment complementation technology using functionalized nanowire. , 2007, Biosensors & bioelectronics.

[21]  Koji Suzuki,et al.  Fabrication and characterization of a nanometer-sized optical fiber electrode based on selective chemical etching for scanning electrochemical/optical microscopy. , 2006, Analytical chemistry.

[22]  K. Oka,et al.  Liquid chromatography and radioimmunoassay compared for determination of cortisol and corticosterone in plasma after a dexamethasone suppression test. , 1987, Clinical chemistry.

[23]  J-P Raskin,et al.  Electrical detection of DNA hybridization: three extraction techniques based on interdigitated Al/Al2O3 capacitors. , 2007, Biosensors & bioelectronics.

[24]  P. Lepage,et al.  Radioimmunoassay for Cortisol in Pig Saliva and Serum , 1997 .

[25]  Zbigniew Stojek,et al.  Voltammetry in solutions of low ionic strength. Electrochemical and analytical aspects , 1999 .

[26]  W. A. Kaptein,et al.  Analysis of cortisol with a flow displacement immunoassay , 1997 .

[27]  T. Tsukahara,et al.  Multi-wall carbon nanotubes (MWCNTs)-doped polypyrrole DNA biosensor for label-free detection of genetically modified organisms by QCM and EIS. , 2010, Talanta.

[28]  W. Gozansky,et al.  Salivary cortisol determined by enzyme immunoassay is preferable to serum total cortisol for assessment of dynamic hypothalamic–pituitary–adrenal axis activity , 2005, Clinical endocrinology.

[29]  I. Suni,et al.  Impedance biosensor for peanut protein Ara h 1. , 2008, Analytical chemistry.

[30]  Yanbin Li,et al.  A self-assembled monolayer-based piezoelectric immunosensor for rapid detection of Escherichia coli O157:H7. , 2004, Biosensors & bioelectronics.

[31]  I. Willner,et al.  Probing Biomolecular Interactions at Conductive and Semiconductive Surfaces by Impedance Spectroscopy: Routes to Impedimetric Immunosensors, DNA‐Sensors, and Enzyme Biosensors , 2003 .

[32]  Nicole Jaffrezic-Renault,et al.  Label-free detection of bacteria by electrochemical impedance spectroscopy: comparison to surface plasmon resonance. , 2007, Analytical chemistry.

[33]  Marco Mascini,et al.  Planar electrochemical sensors for biomedical applications. , 2006, Medical engineering & physics.

[34]  V. Urlacher,et al.  A fluorimetric assay for cortisol , 2005, Analytical and Bioanalytical Chemistry.

[35]  P. Skládal,et al.  The immunosensors for measurement of 2,4-dichlorophenoxyacetic acid based on electrochemical impedance spectroscopy. , 2004, Bioelectrochemistry.

[36]  S. Wessely,et al.  Diurnal excretion of urinary cortisol, cortisone, and cortisol metabolites in chronic fatigue syndrome. , 2006, Journal of psychosomatic research.

[37]  J. Briegel,et al.  Free serum cortisol: quantification applying equilibrium dialysis or ultrafiltration and an automated immunoassay system , 2007, Clinical chemistry and laboratory medicine.

[38]  E. Barsoukov,et al.  Impedance spectroscopy : theory, experiment, and applications , 2005 .

[39]  D. Sgoutas,et al.  Improved ultrafiltration method for determining unbound cortisol in plasma. , 1980, Clinical chemistry.

[40]  Joseph Wang,et al.  Electrochemical biosensors: towards point-of-care cancer diagnostics. , 2006, Biosensors & bioelectronics.