The State of the Art and Advance of the Research and Application of Solid Silver-silver Chloride Reference Electrodes

The research and application of solid silver -silver chloride reference electrodes,includ- ing the fabrication and application of the solid reference electrodes and the micro solid reference electrodes were reviewed. Special attention was paid to the influencing factors on the stability and durability of the solid reference electrodes as well as the performances. The improvements of the solid reference electrodes were discussed.

[1]  I-Yu Huang,et al.  Fabrication and characterization of a new planar solid-state reference electrode for ISFET sensors , 2002 .

[2]  Artur Dybko,et al.  All-solid-state miniaturised planar reference electrodes based on ionic liquids , 2006 .

[3]  W F Jackson,et al.  Toxic Effects of Silver‐Silver Chloride Electrodes on Vascular Smooth Muscle , 1983, Circulation research.

[4]  Zhang Ling-ling RESEARCH PROGRESS OF REFERENCE ELECTRODE FOR ENGINEERING , 2006 .

[5]  Isao Karube,et al.  Problems associated with the thin-film Ag/AgCl reference electrode and a novel structure with improved durability , 1998 .

[6]  J M Cooper,et al.  Single-cell measurements of purine release using a micromachined electroanalytical sensor. , 1998, Analytical chemistry.

[7]  Samuel P. Kounaves,et al.  Fabrication and Characterization of a Solid State Reference Electrode for Electroanalysis of Natural Waters with Ultramicroelectrodes , 1997 .

[8]  D. J. Harrison,et al.  Prevention of the rapid degradation of subcutaneously implanted Ag/AgCl reference electrodes using polymer coatings. , 1994, Analytical chemistry.

[9]  Byoung-Ho Kang,et al.  Enhancement of physical and chemical properties of thin film Ag/AgCl reference electrode using a Ni buffer layer , 2004 .

[10]  A novel thin-film Ag/AgCl anode structure for microfabricated Clark-type oxygen electrodes , 1998 .

[11]  I-Yu Huang,et al.  Improvement of integrated Ag/AgCl thin-film electrodes by KCl-gel coating for ISFET applications , 2003 .

[12]  Isao Karube,et al.  An integrated three-electrode system with a micromachined liquid-junction Ag/AgCl reference electrode , 1999 .

[13]  D. E. Rice,et al.  Conductivity of Anodic Silver Chloride during Formation , 1984 .

[14]  Kristin Syverud,et al.  Towards a solid state reference electrode , 1997 .

[15]  N. Ito,et al.  Development of a micro-planar Ag/AgCl quasi-reference electrode with long-term stability for an amperometric glucose sensor , 2002 .

[16]  Isao Karube,et al.  Micromachined liquid-junction Ag/AgCl reference electrode , 1998 .

[17]  R. Wightman,et al.  Simultaneous detection of catecholamine exocytosis and Ca2+ release from single bovine chromaffin cells using a dual microsensor. , 1998, Analytical chemistry.

[18]  D. Macdonald,et al.  External Reference Electrodes for Use in High Temperature Aqueous Systems , 1979 .

[19]  F. Ansuini,et al.  Factors Affecting the Accuracy of Reference Electrodes , 1994 .

[20]  R. Buck,et al.  Impedance characterization of anodized silver/silver chloride electrodes , 1980 .

[21]  H. Thirsk,et al.  A study of the behaviour of polarized electrodes. Part 3.—The behaviour of the silver/silver chloride system during electrolytic reduction , 1952 .

[22]  S. Woodward How Fibroblasts and Giant Cells Encapsulate Implants: Considerations in Design of Glucose Sensors , 1982, Diabetes Care.

[23]  Liu Yu,et al.  Determination of the chloride threshold concentration for reinforcing steel corrosion initiation in simulated concrete pore solution , 2006 .