On-site evaluation of pedestrian-level air quality at a U-type street canyon in an ancient city

Abstract Urban building disposition plays an important role in determining local microclimate including air quality. Ancient cities normally have some special building dispositions to reduce the penetration of cold wind in winter, which, however, may impact adversely on air pollutant dilution today. This paper investigated the pedestrian-level air quality at a common building disposition in Chinese ancient cities, namely a U-type street canyon. On-site measurements were conducted comparatively at a U-type street canyon and a nearby open space in Xi'an China during January 2015. Three primary air pollutants (PM10, PM2.5 and NO2) as well as wind speed and direction, air temperature and relative humidity were measured continuously from 8:00 a.m. to 8:00 p.m. for a six-day period that covered both clean and hazy days. Pedestrian-level wind condition at the U-type street canyon is mostly independent of that above the canyon, where adverse dilution condition is clearly evident for pollutants. PM2.5/PM10 ratio at the street canyon reached up to 0.9, which is nearly twice that at the nearby observatory. Overall, air quality index (AQI) in the street canyon is, on average, higher by 20% than that at the open space. These findings suggest that this ancient design should be discouraged.

[1]  R. Burnett,et al.  The Relationship Among TSP, PM10, PM2.5, and Inorganic Constituents of Atmospheric Participate Matter at Multiple Canadian Locations , 1997 .

[2]  Cheuk Ming Mak,et al.  From street canyon microclimate to indoor environmental quality in naturally ventilated urban buildings: Issues and possibilities for improvement , 2015, Building and Environment.

[3]  J. Seinfeld,et al.  Time scales to achieve atmospheric gas-aerosol equilibrium for volatile species , 1996 .

[4]  Cheuk Ming Mak,et al.  On-site measurements of ventilation performance and indoor air quality in naturally ventilated high-rise residential buildings in Hong Kong , 2015 .

[5]  Griša Močnik,et al.  Impact of traffic volume and composition on the air quality and pedestrian exposure in urban street canyon , 2014 .

[6]  A. G. Clarke,et al.  The relative significance of vehicular emissions and other emissions of volatile organic compounds in the urban area of Leeds, UK , 1996 .

[7]  K. Pericleous,et al.  Modelling air quality in street canyons : a review , 2003 .

[8]  D. Carslaw Evidence of an increasing NO2/NOX emissions ratio from road traffic emissions , 2005 .

[9]  Gerald Mills,et al.  An analysis of the circulation characteristics and energy budget of a dry, asymmetric, east-west urban canyon. I: Circulation characteristics , 1994 .

[10]  Bin Zhao,et al.  Contribution of outdoor-originating particles, indoor-emitted particles and indoor secondary organic aerosol (SOA) to residential indoor PM2.5 concentration: A model-based estimation , 2015 .

[11]  E. Andreou,et al.  Investigation of urban canyon microclimate in traditional and contemporary environment. Experimental investigation and parametric analysis , 2012 .

[12]  Jianguo Wu,et al.  Fengshui theory in urban landscape planning , 2007, Urban Ecosystems.

[13]  M. Santamouris,et al.  Experimental investigation of air flow and temperature distribution in deep urban canyons for natural ventilation purposes , 2006 .

[14]  S. Kot,et al.  Dispersion of vehicular emission in street canyons, Guangzhou City, South China (P.R.C.) , 1993 .

[15]  E. Ng Policies and technical guidelines for urban planning of high-density cities – air ventilation assessment (AVA) of Hong Kong , 2008, Building and Environment.

[16]  Goodarz Ahmadi,et al.  Airflow and pollutant transport in street canyons , 2006 .

[17]  J. Monteith,et al.  Boundary Layer Climates. , 1979 .

[18]  J. Chow,et al.  Characterization of chemical species in PM2.5 and PM10 aerosols in Hong kong , 2003 .

[19]  Edward Ng,et al.  A study of the " wall effect" caused by proliferation of high-rise buildings using GIS techniques , 2011 .

[20]  Zhaolin Gu,et al.  PM2.5 and PM10-2.5 chemical composition and source apportionment near a Hong Kong roadway , 2015 .

[21]  Kenny C. S Kwok,et al.  CFD simulation of the effect of an upstream building on the inter-unit dispersion in a multi-story building in two wind directions , 2016, Journal of Wind Engineering and Industrial Aerodynamics.

[22]  Jonas Allegrini,et al.  Analysis of convective heat transfer at building façades in street canyons and its influence on the predictions of space cooling demand in buildings , 2012 .

[23]  Z. Gu,et al.  Air quality by urban design , 2013 .

[24]  Fang Yang,et al.  Numerical simulations of the effect of outdoor pollutants on indoor air quality of buildings next to a street canyon , 2015 .

[25]  Stephan Weber,et al.  Flow characteristics and particle mass and number concentration variability within a busy urban street canyon , 2006 .

[26]  Hazim B. Awbi,et al.  Building cluster and shading in urban canyon for hot dry climate , 2004 .

[27]  Mark J. Nieuwenhuijsen,et al.  Fine particulate matter and carbon monoxide exposure concentrations in urban street transport microenvironments , 2007 .

[28]  J. Mattsson,et al.  Canyon geometry, street temperatures and urban heat island in malmö, sweden , 1985 .

[29]  D. Pearlmutter,et al.  Microclimatic analysis of “compact” urban canyons in an arid zone , 1999 .

[30]  Ryozo Ooka,et al.  A study on air pollutant dispersion with bimolecular reactions in urban street canyons using large-eddy simulations , 2012 .

[31]  R. Sokhi,et al.  The Use of Measurement Programmes and Models to Assess Concentrations Next to Major Roads in Urban Areas , 2000 .

[32]  Alexis K.H. Lau,et al.  Air ventilation impacts of the "wall effect" resulting from the alignment of high-rise buildings , 2009 .

[33]  Z T Ai,et al.  Numerical investigation of wind-induced airflow and interunit dispersion characteristics in multistory residential buildings. , 2013, Indoor air.

[34]  M. Santamouris,et al.  Experimental study of temperature and airflow distribution inside an urban street canyon during hot summer weather conditions—Part I: Air and surface temperatures , 2008 .

[35]  L. Shashua-Bar,et al.  Geometry and orientation aspects in passive cooling of canyon streets with trees , 2003 .

[36]  T. Oke,et al.  Wind, temperature and stability conditions in an east-west oriented urban canyon , 1988 .

[37]  F. T. Depaul,et al.  Measurements of wind velocities in a street canyon , 1986 .

[38]  Cheuk Ming Mak,et al.  A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions , 2014 .

[39]  Judith C. Chow,et al.  Characterization and source apportionment of atmospheric organic and elemental carbon during fall and winter of 2003 in Xi'an, China , 2005 .

[40]  Mei-Lien Chen,et al.  The PM2.5 and PM10 particles in urban areas of Taiwan. , 1999, The Science of the total environment.

[41]  D. N. Asimakopoulos,et al.  Thermal and air flow characteristics in a deep pedestrian canyon under hot weather conditions , 1999 .

[42]  G. T. Johnson,et al.  An investigation of three-dimensional characteristics of flow regimes within the urban canyon , 1992 .

[43]  Theodore Stathopoulos,et al.  Assessment of near-field pollutant dispersion: Effect of upstream buildings , 2012 .

[44]  Robert J. Yamartino,et al.  Development and evaluation of simple models for the flow, turbulence and pollutant concentration fields within an urban street canyon , 1986 .

[45]  J. Lodge Air quality guidelines for Europe: WHO regional publications, European series, No. 23, World Health Organization, 1211 Geneva 27, Switzerland; WHO publications center USA, 49 Sheridan Avenue, Albany, NY 12210, 1987, xiii + 426 pp. price: Sw. fr. 60 , 1988 .