Suspended particles in the drinking water of two distribution systems

The concentrations of suspended particles were measured in the drinking water of two distribution systems, and the nature of these particles documented. The concentrations of particulate matter were invariably found to be small (maximum 350 μg/L). They are globally in the very low range in comparison with dissolved matter concentrations, which are measured in several hundreds of mg/L. Except during special water quality events, such as turnover of the raw water resource, results show that organic matter represents the most important fraction of suspended solids (from 40 to 76%) in treated and distributed water. Examination of the nature of the particles made it possible to develop several hypotheses about the type of particles penetrating Montreal's distribution system during the turnover period (algae skeleton, clays). These particles were found to have been transported throughout the distribution systems quite easily, and this could result in the accumulation of deposits if their surface charge were ever even slightly destabilised, or if the particles were to penetrate the laminar flow areas that are fairly typical of remote locations in distribution systems.

[1]  John T. O'Connor,et al.  Seasonal Effects on Generation of Particle-Associated Bacteria During Distribution , 1996 .

[2]  J. Block,et al.  Chlorine Inactivation of SphingomonasCells Attached to Goethite Particles in Drinking Water , 1999, Applied and Environmental Microbiology.

[3]  Mark W. LeChevallier,et al.  Examining Relationships Between Particle Counts and Giardia, Cryptosporidium, and Turbidity , 1992 .

[4]  R. D. Morris,et al.  Temporal variation in drinking water turbidity and diagnosed gastroenteritis in Milwaukee. , 1996, American journal of public health.

[5]  A. Amirtharajah,et al.  Detachment of particles during biofilter backwashing , 1998 .

[6]  I. Toms,et al.  Remobilization of polynuclear aromatic hydrocarbons from the coal tar lining of water mains , 1996 .

[7]  Vincent Gauthier,et al.  Organic matter as loose deposits in a drinking water distribution system , 1999 .

[8]  A. Camper,et al.  Attachment and fate of carbon fines in simulated drinking water distribution system biofilms , 1997 .

[9]  Desmond F. Lawler,et al.  Contact Filtration: Particle Size and Ripening , 1992 .

[10]  M. Hodgkinson,et al.  Deposition of manganese in a drinking water distribution system , 1990, Applied and environmental microbiology.

[11]  A K Camper,et al.  Bacteria associated with granular activated carbon particles in drinking water , 1986, Applied and environmental microbiology.

[12]  Dirk Schoenen,et al.  Invertebrate colonization of granular activated carbon filters , 1997 .

[13]  Caroline S.B. Fitzpatrick,et al.  Filter backwash and start-up strategies for enhanced particulate removal , 1996 .

[14]  P. Westerhoff,et al.  Particle Size and Chemical Effects on Contact Filtration Performance , 1993 .