An Image-Guided Robotic Surgery System for Spinal Fusion

The goal of this work is to develop and test a robot-assisted surgery system for spinal fusion. The system is composed of a robot, a surgical planning system, and a navigation system. It plays the role of assisting surgeons for inserting a pedicle screw in the spinal fusion procedure. Compared to conventional methods for spinal fusion, the proposed surgical procedure ensures minimum invasion and better accuracy by using robot and image information. The robot plays the role of positioning and guiding needles, drills, and other surgical instruments or conducts automatic boring and screwing. Pre-operative CT images intra-operative fluoroscopic images are integrated to provide the surgeon with information for surgical planning. Some experiments employing the developed robotic surgery system are conducted. The experimental results confirm that the system is not only able to guide the surgical tools by accurately pointing and orienting the specified location, but also successfully compensate the movement of the patient due to respiration.

[1]  Byung-Ju Yi,et al.  Development of SPINEBOT for spine surgery , 2004, 2004 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (IEEE Cat. No.04CH37566).

[2]  Alexander R. Vaccaro,et al.  Overview of Computer-Assisted Image-Guided Surgery of the Spine , 2008 .

[3]  Leo Joskowicz,et al.  Bone-mounted miniature robot for surgical procedures: Concept and clinical applications , 2003, IEEE Trans. Robotics Autom..

[4]  Tobias Hüfner,et al.  Pedicle Screw Placement , 2004 .

[5]  Beom-Hee Lee,et al.  A New Analytical Representation to Robot Path Generation with Collision Avoidance through the Use of the Collision Map , 2006 .

[6]  Seungho Kim,et al.  Feeder Pipe Inspection Robot with an Inch-Worm Mechanism Using Pneumatic Actuators , 2006 .

[7]  D. R. Jacobson,et al.  CT determination of pedicle canal diameter , 1989, Images of the Twenty-First Century. Proceedings of the Annual International Engineering in Medicine and Biology Society,.

[8]  B. Green,et al.  Computer-assisted Fluoroscopic Targeting System for Pedicle Screw Insertion , 2000, Neurosurgery.

[9]  P. Robertson,et al.  Radiation Exposure During Fluoroscopically Assisted Pedicle Screw Insertion in the Lumbar Spine , 2000, Spine.

[10]  H. Sagi,et al.  Electromagnetic Field-Based Image-Guided Spine Surgery Part One: Results of a Cadaveric Study Evaluating Lumbar Pedicle Screw Placement , 2003, Spine.

[11]  W. Castro,et al.  Accuracy of Pedicle Screw Placement in Lumbar Vertebrae , 1996, Spine.

[12]  Tae-Hyoung Park,et al.  Path planning of automatic optical inspection machines for PCB assembly systems , 2005, 2005 International Symposium on Computational Intelligence in Robotics and Automation.

[13]  K. S. Arun,et al.  Least-Squares Fitting of Two 3-D Point Sets , 1987, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[14]  U Weber,et al.  Clinical Relevance of Accuracy of Pedicle Screw Placement: A Computed Tomographic‐Supported Analysis , 1998, Spine.

[15]  Il Hong Suh,et al.  Design and analysis of a spatial 3-DOF micromanipulator for tele-operation , 2001, Proceedings 2001 IEEE/RSJ International Conference on Intelligent Robots and Systems. Expanding the Societal Role of Robotics in the the Next Millennium (Cat. No.01CH37180).

[16]  E. W. Fritsch,et al.  Navigation in Spinal Surgery Using Flouroscopy , 2004 .

[17]  A. Prescher,et al.  Computer-Assisted Orthopedic Surgery With Individual Templates and Comparison to Conventional Operation Method , 2001, Spine.

[18]  Peter Knappe,et al.  An interactive mechatronic assistance system to support surgical interventions , 2004, CARS.

[19]  Marcel Rooze,et al.  Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine , 2003, European Spine Journal.

[20]  J. Challis A procedure for determining rigid body transformation parameters. , 1995, Journal of biomechanics.

[21]  W Rüther,et al.  Clinical evaluation and computed tomography scan analysis of screw tracts after percutaneous insertion of pedicle screws in the lumbar spine. , 2000, Spine.

[22]  H. Sagi,et al.  Electromagnetic Field-Based Image-Guided Spine Surgery Part Two: Results of a Cadaveric Study Evaluating Thoracic Pedicle Screw Placement , 2003, Spine.