High-Fidelity Model of Stand-Alone Diesel Electric Generator With Hybrid Turbine-Governor Configuration for Microgrid Studies

Diesel electric generators are an inherent part of remote hybrid microgrids found in remote regions of the world that provide primary frequency response (PFR) to restore system frequency during load or generation changes. However, with inverter-based resources (IBR) integration into microgrids, the IBR control provides a fast frequency response (FFR) to restore the system frequency. Hence, supplementing PFR with FFR requires a sophisticated control system and a high fidelity diesel electric generator model to design these control systems. In this work, a high-fidelity model of a diesel electric generator is developed. Its parameters are tuned using a surrogate optimization algorithm by emulating its response during a load change to a 400 kVA Caterpillar C-15 diesel generator, similar to those found in remote microgrids. The diesel electric generator model consists of a synchronous machine, DC4B excitation with V/Hz limiter, and a proposed modified IEEE GGOV1 engine-governor model (GGOV1D). The performance of the GGOV1D is compared with simple, Woodward DEGOV, and a standard IEEE GGOV1 engine-governor model. Results show that error in the diesel electric generator’s response to load changes using the GGOV1D model is lower with an improved frequency response during the arresting and rebound period than the other engine-governor models.

[1]  T. K. Vrana,et al.  System Impact Studies for Near 100% Renewable Energy Systems Dominated by Inverter Based Variable Generation , 2022, IEEE Transactions on Power Systems.

[2]  R. Tonkoski,et al.  Model Development of Diesel Generator using Volts/Hertz Limiter and Comparing Governor Models for Remote Islanded Microgrids , 2021, IECON 2021 – 47th Annual Conference of the IEEE Industrial Electronics Society.

[3]  Seyyed Rashid Khazeiynasab,et al.  PMU Measurement Based Generator Parameter Calibration by Black-Box Optimization with A Stochastic Radial Basis Function Surrogate Model , 2021, 2020 52nd North American Power Symposium (NAPS).

[4]  Gabriela Hug,et al.  Understanding Small-Signal Stability of Low-Inertia Systems , 2021, IEEE Transactions on Power Systems.

[5]  Ning Lu,et al.  Diesel Generator Model Parameterization for Microgrid Simulation Using Hybrid Box-Constrained Levenberg-Marquardt Algorithm , 2020, ArXiv.

[6]  A. Abuhussein,et al.  Transient Stability Microgrid Model for Arctic Community Integration , 2020, 2020 IEEE/PES Transmission and Distribution Conference and Exposition (T&D).

[7]  Yi Han,et al.  Fast frequency response of inverter-based resources and its impact on system frequency characteristics , 2020 .

[8]  Xiaoqiang Guo,et al.  Large-disturbance stability for power-converter-dominated microgrid: A review , 2020 .

[9]  David J. Hill,et al.  Stability definitions and characterization of dynamic behavior in systems with high penetration of power electronic interfaced technologies , 2020 .

[10]  Marco Liserre,et al.  Microgrid Stability Definitions, Analysis, and Examples , 2020, IEEE Transactions on Power Systems.

[11]  Chao-Ming Huang,et al.  A Hierarchical Optimization Method for Parameter Estimation of Diesel Generators , 2020, IEEE Access.

[12]  Richard W. Wies,et al.  Renewable Energy Integration in Alaska’s Remote Islanded Microgrids: Economic Drivers, Technical Strategies, Technological Niche Development, and Policy Implications , 2019, Proceedings of the IEEE.

[13]  Gabriela Hug,et al.  Understanding Stability of Low-Inertia Systems , 2019 .

[14]  N. Nair,et al.  Voltage and Frequency Response of Small Hydro Power Plant in Grid Connected and Islanded Mode , 2018, 2018 Australasian Universities Power Engineering Conference (AUPEC).

[15]  K. Rudion,et al.  Modelling and Control Optimization of Diesel Synchronous Generators in LV Microgrids , 2018, 2018 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT-Europe).

[16]  Jan Melkebeek The Synchronous Machine , 2018 .

[17]  Timothy M. Hansen,et al.  Virtual Inertia: Current Trends and Future Directions , 2017 .

[18]  Orie Sakamoto,et al.  An example of a diesel generator model with fluctuating engine torque for transient analysis using XTAP , 2016 .

[19]  Hasan Rıza Özçalık,et al.  Dynamic Simulation of a PV-Diesel-Battery Hybrid Plant for Off Grid Electricity Supply , 2015 .

[20]  Babu Narayanan,et al.  POWER SYSTEM STABILITY AND CONTROL , 2015 .

[21]  Christine A. Shoemaker,et al.  A General Stochastic Algorithmic Framework for Minimizing Expensive Black Box Objective Functions Based on Surrogate Models and Sensitivity Analysis , 2014, 1410.6271.

[22]  Richard W. Wies,et al.  DEVELOPMENT OF A FULL-SCALE-LAB-VALIDATED DYNAMIC SIMULINK © MODEL FOR A STAND-ALONE WIND-POWERED MICROGRID , 2014 .

[23]  Marija Mirošević,et al.  The dynamics of diesel-generator unit in isolated electrical network , 2011 .

[24]  Chul-Hwan Kim,et al.  A Frequency-Control Approach by Photovoltaic Generator in a PV–Diesel Hybrid Power System , 2011, IEEE Transactions on Energy Conversion.

[25]  H. Nikkhajoei,et al.  Distributed Generation Interface to the CERTS Microgrid , 2009, IEEE Transactions on Power Delivery.

[26]  R.C. Schaefer,et al.  Tuning a PID controller for a digital excitation control system , 2005, IEEE Transactions on Industry Applications.

[27]  Stavros A. Papathanassiou,et al.  Dynamic characteristics of autonomous wind–diesel systems , 2001 .

[28]  Hans-Martin Gutmann,et al.  A Radial Basis Function Method for Global Optimization , 2001, J. Glob. Optim..

[29]  George Stavrakakis,et al.  A general simulation algorithm for the accurate assessment of isolated diesel-wind turbines systems interaction. I. A general multimachine power system model , 1995 .

[30]  George Stavrakakis,et al.  A general simulation algorithm for the accurate assessment of isolated diesel-wind turbines systems interaction. Part II: Implementation of the algorithm and case-studies with induction generators , 1995 .

[31]  K. E. Yeager,et al.  Modeling of emergency diesel generators in an 800 megawatt nuclear power plant , 1993 .

[32]  William B. Gish,et al.  Small Induction Generator and Synchronous Generator Constants for DSG Isolation Studies , 1986, IEEE Transactions on Power Delivery.