Mutual interference effects between two high-rise building models with different shapes on local peak pressure coefficients

Abstract This study investigates the interference effects between two high-rise buildings with different shapes by wind tunnel experiments, focusing on local peak pressure coefficients. To examine the interference effects for local peak pressures in detail, interference factors for maximum positive and minimum negative peak pressures at each measurement point “i” of the principal building for all wind directions are presented and discussed. The results show that these effects greatly depend on building shapes and wind directions. They also show that special care should be taken with cladding design at the vertical edges, especially corners of buildings, since the smallest minimum peak pressure on a building face might be 40% larger than in the isolated condition.

[1]  Kit Ming Lam,et al.  Wind-induced loading and dynamic responses of a row of tall buildings under strong interference , 2011 .

[2]  Z. N. Xie,et al.  Mean interference effects among tall buildings , 2004 .

[3]  J. Holmes Equivalent time averaging in wind engineering , 1997 .

[4]  Gray De Bureau of standards. , 1989 .

[5]  J. R. Mayne,et al.  A novel working approach to the assessment of wind loads for equivalent static design , 1979 .

[6]  Kit Ming Lam,et al.  Interference effects on wind loading of a row of closely spaced tall buildings , 2008 .

[7]  H. Irwin,et al.  Correction of distortion effects caused by tubing systems in measurements of fluctuating pressures , 1979 .

[8]  J. G. Zhao,et al.  Interference effects in a group of tall buildingsclosely arranged in an L- or T-shaped pattern , 2008 .

[9]  Ling Zhang,et al.  RBF neural networks for the prediction of building interference effects , 2004 .

[10]  C. Harris,et al.  Influence of neighboring structures on the wind pressure on tall buildings , 1934 .

[11]  Kenny C. S Kwok,et al.  Interference excitation mechanisms on a 3DOF aeroelastic CAARC building model , 2004 .

[12]  T. V. Lawson The design of cladding , 1976 .

[13]  Ming Gu,et al.  Simplified formulas for evaluation of wind-induced interference effects among three tall buildings , 2007 .

[14]  Kenny C. S Kwok,et al.  Interference excitation of twin tall buildings , 1985 .

[15]  Theodore Stathopoulos,et al.  Generalization of wind-induced interference effects for two buildings , 2000 .

[16]  Yu Zhou,et al.  Strouhal numbers, forces and flow structures around two tandem cylinders of different diameters , 2008 .

[17]  Yukio Tamura,et al.  Interference effects on local peak pressures between two buildings , 2011 .

[18]  Fergus R. Fricke,et al.  The interference index and its prediction using a neural network analysis of wind-tunnel data , 1999 .