Wiring for the secure storage module for the Plutonium Protection System

The wiring for the SSM is divided into two major subsystems: the logic subsystem and the power subsystem. The logic subsystem uses flat ribbon cables and printed wiring cards for low-level signal distribution. Its primary purpose is to provide communications from the Container Modules (CMs) directly to the microcomputer in the SSM Controller. The power subsystem uses conventional cables and does not generally handle signals of less than 30 volts. The 110V ac power is routed to all equipment in the Electronic Enclosure and to cubicle cooling fans. Wiring for drive power and monitor signals for the carrousel stepper motors, deadbolts, and CM-locking solenoids are provided, as well as for the annuciator status lights and tamper switches.