Accurate Estimation of Gaseous Strength Using Transient Data

Information about the strength of gas sources in buildings has a number of applications in the area of building automation and control, including temperature and ventilation control, fire detection, and security systems. In this paper, we consider the problem of estimating the strength of a gas source in an enclosure when some of the parameters of the gas transport process are unknown. Traditionally, these problems are either solved by the maximum-likelihood method, which is accurate but computationally intensive, or by recursive least squares (also Kalman) filtering, which is simpler but less accurate. In this paper, we suggest a different statistical estimation procedure based on the concept of method of moments. We outline techniques that make this procedure computationally efficient and amenable for recursive implementation. We provide a comparative analysis of our proposed method based on experimental results, as well as Monte Carlo simulations. When used with the building control systems, these algorithms can estimate the gaseous strength in a room both quickly and accurately and can potentially provide improved indoor air quality in an efficient manner.

[1]  A. Rosenfeld,et al.  Estimates of Improved Productivity and Health from Better Indoor Environments , 1997 .

[2]  Clifford Federspiel,et al.  Estimating the inputs of gas transport processes in buildings , 1997, IEEE Trans. Control. Syst. Technol..

[3]  Thananchai Leephakpreeda,et al.  Occupancy-Based Control of Indoor Air Ventilation: A Theoretical and Experimental Study , 2001 .

[4]  P O Fanger,et al.  Indoor air quality in the 21st century: search for excellence. , 2000, Indoor air.

[5]  Thiagalingam Kirubarajan,et al.  Estimation with Applications to Tracking and Navigation , 2001 .

[6]  J. E. Janssen,et al.  Ventilation for acceptable indoor air quality , 1989 .

[7]  Frank I. Katch,et al.  Exercise Physiology: Energy, Nutrition, and Human Performance , 2006 .

[8]  James E. Braun,et al.  A methodology for estimating occupant CO2 source generation rates from measurements in small commercial buildings , 2007 .

[9]  W. Newey,et al.  Large sample estimation and hypothesis testing , 1986 .

[10]  G. Seber,et al.  Nonlinear Regression: Seber/Nonlinear Regression , 2005 .

[11]  Mike Schell,et al.  Demand Control Ventilation Using CO~2 , 2001 .

[12]  S. Kay Fundamentals of statistical signal processing: estimation theory , 1993 .

[13]  Heshmat A. Aglan Predictive model for CO2 generation and decay in building envelopes , 2003 .

[14]  Pramod K. Varshney,et al.  Accurate estimation of indoor occupancy using gas sensors , 2009, 2009 International Conference on Intelligent Sensors, Sensor Networks and Information Processing (ISSNIP).

[15]  Shengwei Wang,et al.  Experimental Validation of CO2-Based Occupancy Detection for Demand-Controlled Ventilation , 1999 .

[16]  Carlo Bruni,et al.  Estimation of respiratory gas exchange: a comparative study of linear and nonlinear model-based estimation techniques , 2006, IEEE Transactions on Biomedical Engineering.