Real‐time volumetric flow measurements with complex‐difference MRI

Blood flow in large vessels can be noninvasively evaluated with phase‐contrast (PC) MRI by encoding the spin velocity to the image phase. Conventional phase‐difference processing of the flow‐encoded image data yields velocity images. Complex‐difference processing is an alternative to phase‐difference methods, and has the advantage of eliminating signal from stationary spins. In this study, two acquisitions with differential flow encoding are subtracted to yield a single projection that contains signal from only those spins moving in the direction of the flow‐encoding gradients. The increase in acquisition efficiency allows real‐time flow imaging with a temporal window as short as two acquisition lengths (60 ms). Validation of the complex‐difference method by comparison with conventional gated‐segmented PC‐MRI in a flow phantom yielded a correlation of r > 0.99. Peak arterial flow rates in the popliteal artery and desending aorta measured in vivo with the complex‐difference method were 0.92 ± 0.06 of the values measured with conventional PC imaging. Real‐time in vivo volumetric flow imaging of transient flow events is also presented. Magn Reson Med 50:1248–1255, 2003. Published 2003 Wiley‐Liss, Inc.

[1]  R. Herfkens,et al.  Phase contrast cine magnetic resonance imaging. , 1991, Magnetic resonance quarterly.

[2]  R. Meuli,et al.  MR gated subtraction angiography: evaluation of lower extremities. , 1986, Radiology.

[3]  J T Vaughan,et al.  Determination of skeletal muscle perfusion using arterial spin labeling NMRI: Validation by comparison with venous occlusion plethysmography , 2001, Magnetic resonance in medicine.

[4]  Yi Wang,et al.  A complex‐difference phase‐contrast technique for measurement of volume flow rates , 1995, Journal of magnetic resonance imaging : JMRI.

[5]  D N Firmin,et al.  Blood flow imaging by cine magnetic resonance. , 1986, Journal of computer assisted tomography.

[6]  V. Wedeen,et al.  Projective MRI angiography and quantitative flow‐volume densitometry , 1986, Magnetic resonance in medicine.

[7]  D. Greitz,et al.  Skeletal muscle perfusion during exercise using Gd-DTPA bolus detection. , 2000, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[8]  M. Bernstein,et al.  Comparison of phase‐difference and complex‐difference processing in phase‐contrast MR angiography , 1991, Journal of magnetic resonance imaging : JMRI.

[9]  N. Pelc,et al.  Correction of spatially dependent phase shifts for partial Fourier imaging. , 1988, Magnetic resonance imaging.

[10]  F R Korosec,et al.  ECG‐optimized phase contrast line‐scanned MR angiography , 1992, Magnetic resonance in medicine.

[11]  C J Hardy,et al.  A one‐dimensional velocity technique for NMR measurement of aortic distensibility , 1994, Magnetic resonance in medicine.