Improving Photoplethysmographic Measurements Under Motion Artifacts Using Artificial Neural Network for Personal Healthcare

Photoplethysmographic (PPG) measurements are susceptible to motion artifacts (MA) due to movement of the peripheral body parts. In this paper, we present a new approach to identify the MA corrupted PPG beats and then rectify the beat morphology using artificial neural network (ANN). Initially, beat quality assessment was done to identify the clean PPG beats by a pretrained feedback ANN to generate a reference beat template for each person. The PPG data were decomposed using principal component analysis (PCA) and reconstructed using fixed energy retention. A weight coefficient was assigned for each PPG sample in such a way that when they are multiplied, the modified beat morphology matches the reference template. A particle swarm optimization-based technique was utilized to select the best weight vector coefficients to tune another feedback ANN, fed with a set of significant features generated by an auto-encoder from PCA reconstructed data. For real-time implementation, this pretrained ANN was operated in feed-forward mode to directly generate the weight vectors for any subsequent measurements of PPG. The method was validated with PPG data collected from 55 human subjects. An average root-mean-square error of 0.28 and signal-to-noise ratio improvement of 14.54 dB were obtained, with an average improvement of 36% and 47% measurement accuracies on crest time and systolic to diastolic peak height ratio, respectively. With the IEEE Signal Processing Cup 2015 challenge database, Pearson’s correlation coefficient between PPG-estimated and ECG-derived heart rates was 0.990. The proposed method can be useful for personal health monitoring applications.

[1]  E. Pickwell‐MacPherson,et al.  Contactless and continuous monitoring of heart rate based on photoplethysmography on a mattress , 2010, Physiological measurement.

[2]  Zhilin Zhang,et al.  A Robust Random Forest-Based Approach for Heart Rate Monitoring Using Photoplethysmography Signal Contaminated by Intense Motion Artifacts , 2017, Sensors.

[3]  A Torricelli,et al.  Pulse transit time measured by photoplethysmography improves the accuracy of heart rate as a surrogate measure of cardiac output, stroke volume and oxygen uptake in response to graded exercise , 2015, Physiological measurement.

[4]  E. Hari Krishna,et al.  A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter , 2012, IEEE Transactions on Instrumentation and Measurement.

[5]  Q Li,et al.  Dynamic time warping and machine learning for signal quality assessment of pulsatile signals , 2012, Physiological measurement.

[6]  Jeremiah D. Wander,et al.  A combined segmenting and non-segmenting approach to signal quality estimation for ambulatory photoplethysmography , 2014, Physiological measurement.

[7]  Weidong Wang,et al.  Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter , 2014, Biomedical engineering online.

[8]  Thomas Penzel,et al.  An Algorithm for Real-Time Pulse Waveform Segmentation and Artifact Detection in Photoplethysmograms , 2017, IEEE Journal of Biomedical and Health Informatics.

[9]  Mehrdad Nourani,et al.  A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors , 2014, IEEE Journal of Biomedical and Health Informatics.

[10]  Francesco Lamonaca,et al.  Health parameters monitoring by smartphone for quality of life improvement , 2015 .

[11]  Ki H. Chon,et al.  Improving Pulse Rate Measurements during Random Motion Using a Wearable Multichannel Reflectance Photoplethysmograph , 2016, Sensors.

[12]  Jianfeng Weng,et al.  An Improved Pre-processing Approach for Photoplethysmographic Signal , 2005, 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference.

[13]  Zhilin Zhang,et al.  TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise , 2014, IEEE Transactions on Biomedical Engineering.

[14]  Zhilin Zhang,et al.  Photoplethysmography-Based Heart Rate Monitoring in Physical Activities via Joint Sparse Spectrum Reconstruction , 2015, IEEE Transactions on Biomedical Engineering.

[15]  Toshiyo Tamura,et al.  Wearable Photoplethysmographic Sensors—Past and Present , 2014 .

[16]  Mohammad Reza Daliri,et al.  Minimum Noise Estimate filter: a Novel Automated Artifacts Removal method for Field Potentials. , 2016, IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[17]  E. Hari Krishna,et al.  ICA-Based Improved DTCWT Technique for MA Reduction in PPG Signals With Restored Respiratory Information , 2013, IEEE Transactions on Instrumentation and Measurement.

[18]  Rui Pedro Paiva,et al.  Assessment of cardiovascular function from multi-Gaussian fitting of a finger photoplethysmogram , 2015, Physiological measurement.

[19]  E. Hari Krishna,et al.  Use of Multi-Scale Principal Component Analysis for motion artifact reduction of PPG signals , 2011, 2011 IEEE Recent Advances in Intelligent Computational Systems.

[20]  Guang-Zhong Yang,et al.  Ratiometric Artifact Reduction in Low Power Reflective Photoplethysmography , 2011, IEEE Transactions on Biomedical Circuits and Systems.

[21]  Rui Pedro Paiva,et al.  Detection of motion artifact patterns in photoplethysmographic signals based on time and period domain analysis , 2014, Physiological measurement.

[22]  Boby George,et al.  A Novel Calibration-Free Method of Measurement of Oxygen Saturation in Arterial Blood , 2009, IEEE Transactions on Instrumentation and Measurement.

[23]  Ki H. Chon,et al.  A Novel Time-Varying Spectral Filtering Algorithm for Reconstruction of Motion Artifact Corrupted Heart Rate Signals During Intense Physical Activities Using a Wearable Photoplethysmogram Sensor , 2015, Sensors.

[24]  Zhilin Zhang,et al.  Combining Nonlinear Adaptive Filtering and Signal Decomposition for Motion Artifact Removal in Wearable Photoplethysmography , 2016, IEEE Sensors Journal.

[25]  Sun K. Yoo,et al.  Motion artifact reduction in photoplethysmography using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[26]  Nikolaos G. Bourbakis,et al.  A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis , 2010, IEEE Transactions on Systems, Man, and Cybernetics, Part C (Applications and Reviews).

[27]  Alan Murray,et al.  Photoplethysmography Assessments in Cardiovascular Disease , 2006 .

[28]  Peter Xiaoping Liu,et al.  Secondary Peak Detection of PPG Signal for Continuous Cuffless Arterial Blood Pressure Measurement , 2014, IEEE Transactions on Instrumentation and Measurement.

[29]  Kian Davoudi Rad Vital Signs Monitoring Using a New Flexible Polymer Integrated PPG Sensor , 2013 .

[30]  Quan Ding,et al.  Respiratory rate monitoring from the photoplethysmogram via sparse signal reconstruction , 2016, Physiological measurement.

[31]  Steve Warren,et al.  Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data , 2010, IEEE Transactions on Biomedical Engineering.

[32]  Jo Woon Chong,et al.  Photoplethysmograph Signal Reconstruction based on a Novel Motion Artifact Detection-Reduction Approach. Part II: Motion and Noise Artifact Removal , 2014, Annals of Biomedical Engineering.

[33]  Boreom Lee,et al.  Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometry , 2010, Physiological measurement.

[34]  Westgate Road,et al.  Photoplethysmography and its application in clinical physiological measurement , 2007 .

[35]  Hyo-Ki Lee,et al.  Automatic classification of apnea/hypopnea events through sleep/wake states and severity of SDB from a pulse oximeter , 2015, Physiological measurement.

[36]  Weidong Wang,et al.  A comb filter based signal processing method to effectively reduce motion artifacts from photoplethysmographic signals , 2015, Physiological measurement.

[37]  A. B. Hertzman THE BLOOD SUPPLY OF VARIOUS SKIN AREAS AS ESTIMATED BY THE PHOTOELECTRIC PLETHYSMOGRAPH , 1938 .

[38]  K. Ashoka Reddy,et al.  Use of Fourier Series Analysis for Motion Artifact Reduction and Data Compression of Photoplethysmographic Signals , 2009, IEEE Transactions on Instrumentation and Measurement.

[39]  W Karlen,et al.  Photoplethysmogram signal quality estimation using repeated Gaussian filters and cross-correlation , 2012, Physiological measurement.

[40]  Zhilin Zhang,et al.  Photoplethysmography-Based Heart Rate Monitoring Using Asymmetric Least Squares Spectrum Subtraction and Bayesian Decision Theory , 2015, IEEE Sensors Journal.

[41]  Mauro Serpelloni,et al.  Autonomous Wearable System for Vital Signs Measurement With Energy-Harvesting Module , 2016, IEEE Transactions on Instrumentation and Measurement.

[42]  Yi Lu,et al.  Auto-Encoder Based for High Spectral Dimensional Data Classification and Visualization , 2017, 2017 IEEE Second International Conference on Data Science in Cyberspace (DSC).

[43]  Purbadri Ghosal,et al.  Classification of photoplethysmogram signal using self organizing map , 2015, 2015 IEEE International Conference on Research in Computational Intelligence and Communication Networks (ICRCICN).