Hepatic steatosis assessment using ultrasound homodyned-K parametric imaging: the effects of estimators.

Background The homodyned-K (HK) distribution is an important statistical model for describing ultrasound backscatter envelope statistics. HK parametric imaging has shown potential for characterizing hepatic steatosis. However, the feasibility of HK parametric imaging in assessing human hepatic steatosis in vivo remains unclear. Methods In this paper, ultrasound HK μ parametric imaging was proposed for assessing human hepatic steatosis in vivo. Two recent estimators for the HK model, RSK (the level-curve method that uses the signal-to-noise ratio (SNR), skewness, and kurtosis based on the fractional moments of the envelope) and XU (the estimation method based on the first moment of the intensity and two log-moments, namely X- and U-statistics), were investigated. Liver donors (n=72) and patients (n=204) were recruited to evaluate hepatic fat fractions (HFFs) using magnetic resonance spectroscopy and to evaluate the stages of fatty liver disease (normal, mild, moderate, and severe) using liver biopsy with histopathology. Livers were scanned using a 3-MHz ultrasound to construct μ RSK and μ XU images to correlate with HFF analyses and fatty liver stages. The μ RSK and μ XU parametric images were constructed using the sliding window technique with the window side length (WSL) =1-9 pulse lengths (PLs). The diagnostic values of the μ RSK and μ XU parametric imaging methods were evaluated using receiver operating characteristic (ROC) curves. Results For the 72 participants in Group A, the μ RSK parametric imaging with WSL =2-9 PLs exhibited similar correlation with log10(HFF), and the μ RSK parametric imaging with WSL = 3 PLs had the highest correlation with log10(HFF) (r=0.592); the μ XU parametric imaging with WSL =1-9 PLs exhibited similar correlation with log10(HFF), and the μ XU parametric imaging with WSL =1 PL had the highest correlation with log10(HFF) (r=0.628). For the 204 patients in Group B, the areas under the ROC (AUROCs) obtained using μ RSK for fatty stages ≥ mild (AUROC1), ≥ moderate (AUROC2), and ≥ severe (AUROC3) were (AUROC1, AUROC2, AUROC3) = (0.56, 0.57, 0.53), (0.68, 0.72, 0.75), (0.73, 0.78, 0.80), (0.74, 0.77, 0.79), (0.74, 0.78, 0.79), (0.75, 0.80, 0.82), (0.74, 0.77, 0.83), (0.74, 0.78, 0.84) and (0.73, 0.76, 0.83) for WSL =1, 2, 3, 4, 5, 6, 7, 8 and 9 PLs, respectively. The AUROCs obtained using μ XU for fatty stages ≥ mild, ≥ moderate, and ≥ severe were (AUROC1, AUROC2, AUROC3) = (0.75, 0.83, 0.81), (0.74, 0.80, 0.80), (0.76, 0.82, 0.82), (0.74, 0.80, 0.84), (0.76, 0.80, 0.83), (0.75, 0.80, 0.84), (0.75, 0.79, 0.85), (0.75, 0.80, 0.85) and (0.73, 0.77, 0.83) for WSL = 1, 2, 3, 4, 5, 6, 7, 8 and 9 PLs, respectively. Conclusions Both the μ RSK and μ XU parametric images are feasible for evaluating human hepatic steatosis. The WSL exhibits little impact on the diagnosing performance of the μ RSK and μ XU parametric imaging. The μ XU parametric imaging provided improved performance compared to the μ RSK parametric imaging in characterizing human hepatic steatosis in vivo.

[1]  Brian W. Anthony,et al.  Experimental Validation of Longitudinal Speed of Sound Estimates in the Diagnosis of Hepatic Steatosis (Part II). , 2018, Ultrasound in medicine & biology.

[2]  W. O’Brien,et al.  Repeatability and Reproducibility of the Ultrasonic Attenuation Coefficient and Backscatter Coefficient Measured in the Right Lobe of the Liver in Adults With Known or Suspected Nonalcoholic Fatty Liver Disease , 2018, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[3]  Guy Cloutier,et al.  The Added Value of Statistical Modeling of Backscatter Properties in the Management of Breast Lesions at US. , 2015, Radiology.

[4]  Jonathan Mamou,et al.  Quantitative Ultrasound in Soft Tissues , 2013, Springer Netherlands.

[5]  O. Basset,et al.  Quantitative Characterization of Concentrated Cell Pellet Biophantoms using Statistical Models for the Ultrasound Echo Envelope , 2015 .

[6]  Shinsuke Akita,et al.  Verification of echo amplitude envelope analysis method in skin tissues for quantitative follow-up of healing ulcers , 2018, Japanese Journal of Applied Physics.

[7]  Z. Younossi Non-alcoholic fatty liver disease - A global public health perspective. , 2019, Journal of hepatology.

[8]  Chih-Kuang Yeh,et al.  Hepatic Steatosis Assessment with Ultrasound Small-Window Entropy Imaging. , 2018, Ultrasound in medicine & biology.

[9]  Richard W Prager,et al.  Analysis of speckle in ultrasound images using fractional order statistics and the homodyned k-distribution. , 2002, Ultrasonics.

[10]  Ying-Hsiu Lin,et al.  Effect of ultrasound frequency on the Nakagami statistics of human liver tissues , 2017, PloS one.

[11]  Xuelong Li,et al.  Robotic Arm Based Automatic Ultrasound Scanning for Three-Dimensional Imaging , 2019, IEEE Transactions on Industrial Informatics.

[12]  M. Oelze,et al.  11B-4 Quantitative Ultrasound Assessment of Breast Cancer Using a Multiparameter Approach , 2007, 2007 IEEE Ultrasonics Symposium Proceedings.

[13]  Hao-Li Liu,et al.  Three-dimensional Visualization of Ultrasound Backscatter Statistics by Window-modulated Compounding Nakagami Imaging , 2018, Ultrasonic imaging.

[14]  M. Dumont,et al.  European Association for the Study of the Liver , 1971 .

[15]  Qinghua Huang,et al.  Fully Automatic Three-Dimensional Ultrasound Imaging Based on Conventional B-Scan , 2018, IEEE Transactions on Biomedical Circuits and Systems.

[16]  Meng-Su Zeng,et al.  Standardized Ultrasound Hepatic/Renal Ratio and Hepatic Attenuation Rate to Quantify Liver Fat Content: An Improvement Method , 2011, Obesity.

[17]  B. Neuschwander‐Tetri,et al.  Nonalcoholic steatohepatitis: a proposal for grading and staging the histological lesions , 1999, American Journal of Gastroenterology.

[18]  S. Provencher Estimation of metabolite concentrations from localized in vivo proton NMR spectra , 1993, Magnetic resonance in medicine.

[19]  Jae Young Lee,et al.  Evaluation of Hepatic Steatosis by Using Acoustic Structure Quantification US in a Rat Model: Comparison with Pathologic Examination and MR Spectroscopy. , 2017, Radiology.

[20]  Guy Cloutier,et al.  Estimation Method of the Homodyned K-Distribution Based on the Mean Intensity and Two Log-Moments , 2013, SIAM J. Imaging Sci..

[21]  Parameter Estimation of the Homodyned K Distribution Based on Signal to Noise Ratio , 2007 .

[22]  Brian W. Anthony,et al.  Quantitative Hepatic Fat Quantification in Non-alcoholic Fatty Liver Disease Using Ultrasound-Based Techniques: A Review of Literature and Their Diagnostic Performance. , 2018, Ultrasound in medicine & biology.

[23]  Xiaohui Hao,et al.  Characterization of reperfused infarcted myocardium from high-frequency intracardiac ultrasound imaging using homodyned K distribution , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[24]  Chih-Kuang Yeh,et al.  Multifeature analysis of an ultrasound quantitative diagnostic index for classifying nonalcoholic fatty liver disease , 2016, Scientific Reports.

[25]  Shuicai Wu,et al.  Hepatic Steatosis Assessment Using Quantitative Ultrasound Parametric Imaging Based on Backscatter Envelope Statistics , 2019, Applied Sciences.

[26]  Ke-bin Jia,et al.  A Review of Ultrasound Tissue Characterization with Mean Scatterer Spacing , 2017, Ultrasonic imaging.

[27]  M. Oelze,et al.  Three-dimensional high-frequency backscatter and envelope quantification of cancerous human lymph nodes. , 2011, Ultrasound in medicine & biology.

[28]  Shuicai Wu,et al.  A Computer-Aided Diagnosis Scheme For Detection Of Fatty Liver In Vivo Based On Ultrasound Kurtosis Imaging , 2015, Journal of Medical Systems.

[29]  Kazuyuki Ishida,et al.  The B-Mode Image-Guided Ultrasound Attenuation Parameter Accurately Detects Hepatic Steatosis in Chronic Liver Disease. , 2018, Ultrasound in medicine & biology.

[30]  E. Jakeman,et al.  Generalized K distribution: a statistical model for weak scattering , 1987 .

[31]  G. Soulez,et al.  Assessment of Carotid Artery Plaque Components With Machine Learning Classification Using Homodyned-K Parametric Maps and Elastograms , 2019, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[32]  Michal Byra,et al.  Temperature Monitoring during Focused Ultrasound Treatment by Means of the Homodyned K Distribution , 2017 .

[33]  P. Tsui,et al.  Ultrasound parametric imaging of hepatic steatosis using the homodyned‐K distribution: An animal study , 2018, Ultrasonics.

[34]  J. Greenleaf,et al.  Ultrasound echo envelope analysis using a homodyned K distribution signal model. , 1994, Ultrasonic imaging.

[35]  Guy Cloutier,et al.  Unifying Concepts of Statistical and Spectral Quantitative Ultrasound Techniques , 2016, IEEE Transactions on Medical Imaging.

[36]  G. Cloutier,et al.  A critical review and uniformized representation of statistical distributions modeling the ultrasound echo envelope. , 2010, Ultrasound in medicine & biology.

[37]  Minh Do,et al.  In-vivo study of quantitative ultrasound parameters in fatty rabbit livers , 2012, 2017 IEEE International Ultrasonics Symposium (IUS).

[38]  Jasjit S. Suri,et al.  Symtosis: A liver ultrasound tissue characterization and risk stratification in optimized deep learning paradigm , 2018, Comput. Methods Programs Biomed..

[39]  Qinghua Huang,et al.  2.5-D Extended Field-of-View Ultrasound , 2018, IEEE Transactions on Medical Imaging.

[40]  M. Oelze,et al.  Improved parameter estimates based on the homodyned K distribution , 2009, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[41]  J. Zagzebski,et al.  Accuracy of Liver Fat Quantification With Advanced CT, MRI, and Ultrasound Techniques: Prospective Comparison With MR Spectroscopy. , 2017, AJR. American journal of roentgenology.

[42]  W. O’Brien,et al.  Inter-sonographer reproducibility of quantitative ultrasound outcomes and shear wave speed measured in the right lobe of the liver in adults with known or suspected non-alcoholic fatty liver disease , 2018, European Radiology.

[43]  G. Cloutier,et al.  Diagnostic Accuracy of Echo Envelope Statistical Modeling Compared to B‐Mode and Power Doppler Ultrasound Imaging in Patients With Clinically Diagnosed Lateral Epicondylosis of the Elbow , 2019, Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine.

[44]  M. Tanter,et al.  Ultrasonic Adaptive Sound Speed Estimation for the Diagnosis and Quantification of Hepatic Steatosis: A Pilot Study , 2018, Ultraschall in der Medizin - European Journal of Ultrasound.

[45]  Ming-de Lu,et al.  Assessment of liver fibrosis in chronic hepatitis B using acoustic structure quantification: quantitative morphological ultrasound , 2016, European Radiology.

[46]  G. Cloutier,et al.  Quantitative ultrasound and machine learning for assessment of steatohepatitis in a rat model , 2018, European radiology.

[47]  Hsiang-Yang Ma,et al.  Effects of fatty infiltration in human livers on the backscattered statistics of ultrasound imaging , 2015, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[48]  Andrzej Nowicki,et al.  Classification of breast lesions using segmented quantitative ultrasound maps of homodyned K distribution parameters. , 2016, Medical physics.

[49]  Claude B Sirlin,et al.  Liver fat imaging-a clinical overview of ultrasound, CT, and MR imaging. , 2018, The British journal of radiology.

[50]  Jonathan Mamou,et al.  Review of Quantitative Ultrasound: Envelope Statistics and Backscatter Coefficient Imaging and Contributions to Diagnostic Ultrasound , 2016, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[51]  Jae Young Lee,et al.  Hepatic Steatosis: Assessment with Acoustic Structure Quantification of US Imaging. , 2016, Radiology.