Infrared Microspectroscopy Using Prism-Based Spectrographs and Focal Plane Array Detection

Several prism-based spectrographs employing a mercury cadmium telluride (MCT) focal plane array detector have been interfaced to an infrared microscope. In the combined system, the area-defining aperture of the microscope also served as the entrance slit to the spectrograph. This investigation considered the fundamental limits of diffraction for both the spectrograph and microscope in order to determine both the spatial and spectral resolution of the system as a whole. Experimental results for spectral resolution, spectral range, and peak-to-peak noise have been presented. Finally, the dynamic capabilities of one spectrograph/microscope combination were investigated.

[1]  S. Block,et al.  An FT-IR Microspectroscopic Method for Kinetic Measurements at High Temperatures and High Pressures , 1984 .

[2]  Diffraction-Induced Stray Light in Infrared Microspectroscopy and its Effect on Spatial Resolution , 1991 .

[3]  A. Offner,et al.  Design and Performance of an Infrared Microscope Attachment , 1953 .

[4]  D. H. Anderson,et al.  Fourier Transform infrared analysis below the one-nanogram level , 1977 .

[5]  H. Westerhoff,et al.  Absorption spectroscopy. , 2011, Methods in enzymology.

[6]  R. C. Reeder,et al.  Fourier transform spectroscopic imaging using an infrared focal-plane array detector. , 1995, Analytical chemistry.

[7]  R. Gore Infrared spectrometry of small samples with the reflecting microscope. , 1949, Science.

[8]  R. Barer,et al.  Infra-Red Spectroscopy with the Reflecting Microscope in Physics, Chemistry and Biology , 1949, Nature.

[9]  M. J. Abbate,et al.  Infrared microspectroscopy. IV. A double-beam infrared microspectrometer. , 1955, Journal of the Optical Society of America.

[10]  John U. White,et al.  Comparison of LiF and CaF 2 Prisms for Infra-Red Use , 1947 .

[11]  E. Heilweil,et al.  Broadband femtosecond transient infrared spectroscopy using a 256 x 256 element indium antimonide focal-plane detector. , 1997, Optics letters.

[12]  V. Z. Williams Infrared Spectrometry since 1945 , 1951 .

[13]  Daniel C. Harris,et al.  Quantitative Chemical Analysis , 1968, Nature.

[14]  M. J. Abbate,et al.  Infrared Microspectroscopy. III. A Capillary Cell for Liquids , 1952 .

[15]  L H Kidder,et al.  Mercury cadmium telluride focal-plane array detection for mid-infrared Fourier-transform spectroscopic imaging. , 1997, Optics letters.

[16]  John F. Rabolt,et al.  Planar Array Infrared Spectroscopic Imaging of Monolayer Films in the 3200−2800 cm-1 Region , 2003 .

[17]  Curtis Marcott,et al.  Prism-Based Infrared Spectrographs Using Modern-Day Detectors , 2007, Applied spectroscopy.

[18]  George R. Bird,et al.  Infra-red microspectroscopy , 1950 .

[19]  E. Blout,et al.  Infrared microspectroscopy. II. , 1951, Journal of the Optical Society of America.

[20]  Simon Frisk,et al.  Design and Performance of a Planar Array Infrared Spectrograph That Operates in the 3400 to 2000 cm−1 Region , 2002 .

[21]  Christopher M Snively,et al.  Performance and Application of a New Planar Array Infrared Spectrograph Operating in the Mid-Infrared (2000–975 cm−1) Fingerprint Region , 2004, Applied spectroscopy.