CFD study of exhaled droplet transmission between occupants under different ventilation strategies in a typical office room

Abstract This paper investigated the transmission of respiratory droplets between two seated occupants equipped with one type of personalized ventilation (PV) device using round movable panel (RMP) in an office room. The office was ventilated by three different total volume (TV) ventilation strategies, i.e. mixing ventilation (MV), displacement ventilation (DV), and under-floor air distribution (UFAD) system respectively as background ventilation methods. Concentrations of particles with aerodynamic diameters of 0.8 μm, 5 μm, and 16 μm as well as tracer gas were numerically studied in the Eulerian frame. Two indexes, i.e. intake fraction (IF) and concentration uniformity index R C were introduced to evaluate the performance of ventilation systems. It was found that without PV, DV performed best concern protecting the exposed manikin from the pollutants exhaled by the polluting manikin. In MV when the exposed manikin opened RMP the inhaled air quality could always be improved. In DV and UFAD application of RMP might sometimes, depending on the personalized airflow rate, increase the exposure of the others to the exhaled droplets of tracer gas, 0.8 μm particles, and 5 μm particles from the infected occupants. Application of PV could reduce R C for all the three TV systems of 0.8 μm and 5 μm particles. PV enhanced mixing degree of particles under DV and UFAD based conditions much stronger than under MV based ones. PV could increase the average concentration in the occupied zone of the exposed manikin as well as provide clean personalized airflow. Whether inhaled air quality could be improved depended on the balance of pros and cons of PV.

[1]  Hui-lai Ma,et al.  [Non-airborne transmission during outbreak of pandemic (H1N1) 2009 among tour group members, China, June 2009]. , 2010, Zhonghua liu xing bing xue za zhi = Zhonghua liuxingbingxue zazhi.

[2]  A. Hubbard,et al.  Toward Understanding the Risk of Secondary Airborne Infection: Emission of Respirable Pathogens , 2005, Journal of occupational and environmental hygiene.

[3]  A. Melikov,et al.  Impact of airflow interaction on inhaled air quality and transport of contaminants in rooms with personalized and total volume ventilation , 2003 .

[4]  Z. Zhang,et al.  Prediction of Particle Deposition onto Indoor Surfaces by CFD with a Modified Lagrangian Method , 2009 .

[5]  M. P. Wan,et al.  Transport and Removal of Expiratory Droplets in Hospital Ward Environment , 2008 .

[6]  A. Melikov,et al.  Protection of Occupants from Exhaled Infectious Agents and Floor Material Emissions in Rooms with Personalized and Underfloor Ventilation , 2007 .

[7]  Arsen Krikor Melikov,et al.  Performance of Personalized Ventilation in Conjunction with Mixing and Displacement Ventilation , 2006 .

[8]  Alvin C.K. Lai,et al.  Study of expiratory droplet dispersion and transport using a new Eulerian modeling approach , 2007, Atmospheric Environment.

[9]  M. P. Wan,et al.  Modeling the Fate of Expiratory Aerosols and the Associated Infection Risk in an Aircraft Cabin Environment , 2009 .

[10]  M. L. Laucks,et al.  Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles , 2000 .

[11]  Jovan Pantelic,et al.  Personalized ventilation as a control measure for airborne transmissible disease spread , 2009, Journal of The Royal Society Interface.

[12]  A. Lai,et al.  Modeling particle distribution and deposition in indoor environments with a new drift–flux model , 2006 .

[13]  Sinks,et al.  Characterizing sources of indoor air pollution and related sink effects , 1996 .

[14]  D. Rim,et al.  Transport of particulate and gaseous pollutants in the vicinity of a human body , 2009 .

[15]  Jianlei Niu,et al.  Modeling particle dispersion and deposition in indoor environments , 2007, Atmospheric Environment.

[16]  P V Nielsen,et al.  Role of ventilation in airborne transmission of infectious agents in the built environment - a multidisciplinary systematic review. , 2007, Indoor air.

[17]  Guang Zeng,et al.  Lack of Airborne Transmission during Outbreak of Pandemic (H1N1) 2009 among Tour Group Members, China, June 2009 , 2009, Emerging infectious diseases.

[18]  A. Mangili,et al.  Review Transmission , 2022 .

[19]  Alvin C.K. Lai,et al.  Numerical modeling of exhaled droplet nuclei dispersion and mixing in indoor environments , 2009, Journal of Hazardous Materials.

[20]  Kerrie Mengersen,et al.  Size distribution and sites of origin of droplets expelled from the human respiratory tract during expiratory activities , 2009 .

[21]  K. Mengersen,et al.  Characterization of expiration air jets and droplet size distributions immediately at the mouth opening , 2008, Journal of Aerosol Science.

[22]  P. Fanger,et al.  Human response to personalized ventilation and mixing ventilation. , 2004, Indoor air.

[23]  P. Nielsen,et al.  Control of airborne infectious diseases in ventilated spaces , 2009, Journal of The Royal Society Interface.

[24]  Sally Blower,et al.  Calculating the potential for within-flight transmission of influenza A (H1N1) , 2009, BMC medicine.

[25]  Jennifer Richmond-Bryant,et al.  Transport of exhaled particulate matter in airborne infection isolation rooms , 2008, Building and Environment.

[26]  W. Ott,et al.  Accounting for Nonuniform Mixing and Human Exposure in Indoor Environments , 1996 .

[27]  Alvin C.K. Lai,et al.  Modeling Indoor Particle Deposition from Turbulent Flow onto Smooth Surfaces , 2000 .

[28]  Bin Zhao,et al.  Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation. , 2010, Indoor air.

[29]  Jianlei Niu,et al.  Distribution of respiratory droplets in enclosed environments under different air distribution methods , 2008 .

[30]  J. Niu,et al.  CFD Study of the Thermal Environment around a Human Body : A Review , 2005 .

[31]  W. Nazaroff Indoor particle dynamics. , 2004, Indoor air.

[32]  M. P. Wan,et al.  Experimental Study of Dispersion and Deposition of Expiratory Aerosols in Aircraft Cabins and Impact on Infectious Disease Transmission , 2009 .

[33]  Jianren Fan,et al.  Experimental analysis of particle concentration heterogeneity in a ventilated scale chamber , 2009 .