Development of a pan-serotype reverse transcription loop-mediated isothermal amplification assay for the detection of dengue virus

Abstract During dengue outbreaks, acute diagnosis at the patient's point of need followed by appropriate supportive therapy reduces morbidity and mortality. To facilitate needed diagnosis, we developed and optimized a reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay that detects all 4 serotypes of dengue virus (DENV). We used a quencher to reduce nonspecific amplification. The assay does not require expensive thermocyclers, utilizing a simple water bath to maintain the reaction at 63°C. Results can be visualized using UV fluorescence, handheld readers, or lateral flow immunochromatographic tests. We report a sensitivity of 86.3% (95% confidence interval [CI], 72.7–94.8%) and specificity of 93.0% (95% CI, 83.0–98.1%) using a panel of clinical specimens characterized by DENV quantitative reverse transcription–polymerase chain reaction. This pan-serotype DENV RT-LAMP can be adapted to field-expedient formats where it can provide actionable diagnosis near the patient's point of need.

[1]  K. Morita,et al.  Development of simple and rapid assay to detect viral RNA of tick-borne encephalitis virus by reverse transcription-loop-mediated isothermal amplification , 2013, Virology Journal.

[2]  Cheryl Jennings,et al.  HIV-1 Viral Load Assays for Resource-Limited Settings , 2006, PLoS medicine.

[3]  Y. Mori,et al.  Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation. , 2001, Biochemical and biophysical research communications.

[4]  S. Thammapalo,et al.  Rapid detection of dengue viral RNA in mosquitoes by nucleic acid-sequence based amplification (NASBA). , 2006, The Southeast Asian journal of tropical medicine and public health.

[5]  Shingo Inoue,et al.  Real-Time Reverse Transcription Loop-Mediated Isothermal Amplification for Rapid Detection of West Nile Virus , 2004, Journal of Clinical Microbiology.

[6]  T. Notomi,et al.  Accelerated reaction by loop-mediated isothermal amplification using loop primers. , 2002, Molecular and cellular probes.

[7]  Colin J. Sutherland,et al.  Highly Sensitive Detection of Malaria Parasitemia in a Malaria-Endemic Setting: Performance of a New Loop-Mediated Isothermal Amplification Kit in a Remote Clinic in Uganda , 2013, The Journal of infectious diseases.

[8]  Yasuyoshi Mori,et al.  Real-time turbidimetry of LAMP reaction for quantifying template DNA. , 2004, Journal of biochemical and biophysical methods.

[9]  W. Kiatpathomchai,et al.  Rapid and sensitive detection of Macrobrachium rosenbergii nodavirus in giant freshwater prawns by reverse transcription loop-mediated isothermal amplification combined with a lateral flow dipstick. , 2010, Molecular and cellular probes.

[10]  D. Rudolph,et al.  Sequence‐specific detection method for reverse transcription, loop‐mediated isothermal amplification of HIV‐1 , 2009, Journal of medical virology.

[11]  Helen H. Lee,et al.  Sample preparation: a challenge in the development of point-of-care nucleic acid-based assays for resource-limited settings. , 2007, The Analyst.

[12]  M. Seguin,et al.  Rapid identification of dengue virus isolates by using monoclonal antibodies in an indirect immunofluorescence assay. , 1983, The American journal of tropical medicine and hygiene.

[13]  A. Nisalak,et al.  Dengue viremia titer, antibody response pattern, and virus serotype correlate with disease severity. , 2000, The Journal of infectious diseases.

[14]  G. Boiteau,et al.  J. Virol. Methods , 1996, Journal of Virological Methods.

[15]  Jacques Schrenzel,et al.  Robustness of a loop-mediated isothermal amplification reaction for diagnostic applications. , 2011, FEMS immunology and medical microbiology.

[16]  K. Morita,et al.  Development and Evaluation of Reverse Transcription-Loop-Mediated Isothermal Amplification Assay for Rapid and Real-Time Detection of Japanese Encephalitis Virus , 2006, Journal of Clinical Microbiology.

[17]  Shingo Inoue,et al.  Rapid Detection and Differentiation of Dengue Virus Serotypes by a Real-Time Reverse Transcription-Loop-Mediated Isothermal Amplification Assay , 2005, Journal of Clinical Microbiology.

[18]  R. Rico-Hesse Microevolution and virulence of dengue viruses. , 2003, Advances in virus research.

[19]  J. Sattabongkot,et al.  Loop-Mediated Isothermal Amplification Assay for Rapid Diagnosis of Malaria Infections in an Area of Endemicity in Thailand , 2014, Journal of Clinical Microbiology.

[20]  G. Fox,et al.  The molecular epidemiology of dengue viruses: genetic variation and microevolution. , 1990 .

[21]  Tsugunori Notomi,et al.  Development and Evaluation of a Novel Loop-Mediated Isothermal Amplification Method for Rapid Detection of Severe Acute Respiratory Syndrome Coronavirus , 2004, Journal of Clinical Microbiology.

[22]  G. Cao,et al.  Simultaneous detection and differentiation of dengue virus serotypes 1-4, Japanese encephalitis virus, and West Nile virus by a combined reverse-transcription loop-mediated isothermal amplification assay , 2011, Virology Journal.

[23]  Takeshi Ono,et al.  The Direct Boil-LAMP method: a simple and rapid diagnostic method for cutaneous leishmaniasis. , 2014, Parasitology international.

[24]  Kozaburo Hayashi,et al.  Loop-Mediated Isothermal Amplification for Direct Detection of Mycobacterium tuberculosis Complex, M. avium, and M. intracellulare in Sputum Samples , 2003, Journal of Clinical Microbiology.

[25]  Paul LaBarre,et al.  A Simple, Inexpensive Device for Nucleic Acid Amplification without Electricity—Toward Instrument-Free Molecular Diagnostics in Low-Resource Settings , 2011, PloS one.

[26]  Shashi Sharma,et al.  Rapid detection and differentiation of dengue virus serotypes by NS1 specific reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay in patients presenting to a tertiary care hospital in Hyderabad, India , 2014, Journal of Virological Methods.

[27]  R. Sang,et al.  A real-time reverse transcription loop-mediated isothermal amplification assay for the rapid detection of yellow fever virus. , 2013, Journal of virological methods.

[28]  D. Rudolph,et al.  Rapid detection of HIV-1 by reverse-transcription, loop-mediated isothermal amplification (RT-LAMP). , 2008, Journal of virological methods.

[29]  D. Gubler,et al.  Dengue and dengue hemorrhagic fever. , 2014 .

[30]  E. S. Pearson,et al.  THE USE OF CONFIDENCE OR FIDUCIAL LIMITS ILLUSTRATED IN THE CASE OF THE BINOMIAL , 1934 .

[31]  T. Notomi,et al.  Loop-mediated isothermal amplification of DNA. , 2000, Nucleic acids research.

[32]  K Watanabe,et al.  Loop-mediated isothermal amplification reaction using a nondenatured template. , 2001, Clinical chemistry.

[33]  D. Relman,et al.  Improved Amplification of Microbial DNA from Blood Cultures by Removal of the PCR Inhibitor Sodium Polyanetholesulfonate , 1998, Journal of Clinical Microbiology.

[34]  P. Shu,et al.  Current Advances in Dengue Diagnosis , 2004, Clinical Diagnostic Laboratory Immunology.

[35]  Takashi Kawana,et al.  Tolerance of loop-mediated isothermal amplification to a culture medium and biological substances. , 2007, Journal of biochemical and biophysical methods.

[36]  E. Galun,et al.  Comparison of methods for extraction of nucleic acid from hemolytic serum for PCR amplification of hepatitis B virus DNA sequences , 1997, Journal of clinical microbiology.

[37]  J. L. Lima-Filho,et al.  Trends in dengue diagnosis , 2005, Reviews in medical virology.

[38]  Thomas C Evans,et al.  Simultaneous multiple target detection in real-time loop-mediated isothermal amplification. , 2012, BioTechniques.

[39]  Chwan-Chuen King,et al.  Laboratory diagnosis of dengue virus infection: current and future perspectives in clinical diagnosis and public health. , 2005, Journal of microbiology, immunology, and infection = Wei mian yu gan ran za zhi.

[40]  T. Komiya,et al.  Rapid Detection and Quantification of Japanese Encephalitis Virus by Real‐Time Reverse Transcription Loop‐Mediated Isothermal Amplification , 2006, Microbiology and immunology.

[41]  Jiong Chen,et al.  Rapid and sensitive detection of infectious spleen and kidney necrosis virus by loop-mediated isothermal amplification combined with a lateral flow dipstick , 2010, Archives of Virology.

[42]  Kim-Kee Tan,et al.  Detection of dengue viruses using reverse transcription-loop-mediated isothermal amplification , 2013, BMC Infectious Diseases.

[43]  John S. Brownstein,et al.  The global distribution and burden of dengue , 2013, Nature.