Area x-ray beam equalization for digital angiography.

An area beam equalization technique has been investigated in order to generate patient-specific compensating filters for digital angiography. An initial image was used to generate the compensating filter, which was fabricated using a deformable compensating material, containing CeO2, and an array of square pistons. The CeO2 attenuator thicknesses were calculated using the gray level information from the initial unequalized image. The array of pistons was pressed against a uniform thickness of attenuating material to generate a filter for x-ray beam equalization. The filter was subsequently inserted into the x-ray beam for the final equalized radiograph. It was positioned close to the focal spot (magnification of 8.0) in order to minimize edge artifacts from the filter. The equalization of x-ray transmission across the field exiting from the object significantly improved the image quality by preserving local contrast throughout the image. The contrast-to-noise ratio (CNR) in the equalized images was increased-by up to fivefold. Phantom studies indicate that equalized images using a relatively small array of pistons (e.g., 8 x 8) produce significant improvement in image quality with negligible perceptible artifacts. Animal studies showed that beam equalization significantly improved fluoroscopic and angiographic image quality. X-ray beam equalization produced an image with a relatively uniform scatter-glare intensity and it reduced the scatter-glare fraction in the previously underpenetrated region of the image from 0.65 to 0.50. Also, x-ray tube loading due to the mask assembly itself was negligible. In conclusion, area beam equalization reduces the scatter-glare fraction and significantly improves CNR in the previously underpenetrated region of the image.

[1]  C A Mistretta,et al.  Digital beam attenuator technique for compensated chest radiography. , 1986, Radiology.

[2]  C. Vyborny,et al.  Foil filters for equalized chest radiography. , 1984, Radiology.

[3]  D B Plewes,et al.  A scanning system for chest radiography with regional exposure control: practical implementation. , 1983, Medical physics.

[4]  J Duryea,et al.  Filter wheel equalization for chest radiography: a computer simulation. , 1995, Medical physics.

[5]  Sabee Molloi,et al.  Scatter-glare estimation for digital radiographic systems: comparison of digital filtration and sampling techniques , 1998, IEEE Transactions on Medical Imaging.

[6]  C A Mistretta,et al.  Geometrical properties of a digital beam attenuator system. , 1987, Medical physics.

[7]  D L Wilson,et al.  The x-ray fovea, a device for reducing x-ray dose in fluoroscopy. , 1994, Medical physics.

[8]  P. Edholm,et al.  Primary x-ray dodging. , 1971, Radiology.

[9]  S. Molloi,et al.  Scatter and veiling glare estimation based on sampled primary intensity. , 1999, Medical physics.

[10]  J Duryea,et al.  Filter wheel equalization in chest radiography: demonstration with a prototype system. , 1995, Radiology.

[11]  Yao-Jin Qian,et al.  A digital filtration technique for scatter-glare correction based on thickness estimation , 1995, IEEE Trans. Medical Imaging.

[12]  L J Kool,et al.  AMBER: a scanning multiple-beam equalization system for chest radiography. , 1988, Radiology.

[13]  J M Boone,et al.  Filter wheel equalization in DSA: simulation results. , 1993, Medical physics.

[14]  D B Plewes,et al.  A scanning equalization system for improved chest radiography. , 1982, Radiology.

[15]  C A Mistretta,et al.  Quantification techniques for dual-energy cardiac imaging. , 1989, Medical physics.

[16]  D B Plewes,et al.  A scanning system for chest radiography with regional exposure control: theoretical considerations. , 1983, Medical physics.

[17]  S Rudin,et al.  Region of interest fluoroscopy. , 1992, Medical physics.

[18]  N. Petrick,et al.  Classification of compressed breast shapes for the design of equalization filters in x-ray mammography. , 1998, Medical physics.