Clinical accuracy and reproducibility of Portrait 3D Surgical Simulation Platform in breast augmentation.

BACKGROUND Three-dimensional (3D) digital photography uses integrated image capture technology and rendering software to create 3D models. Volumetric measurements project simulated post-operative images prior to breast augmentation. OBJECTIVES To evaluate the accuracy and reproducibility of breast volume measurements using the Portrait 3D Surgical Simulation Platform (Axis Three, Boston, Massachusetts). METHODS Twenty-two patients underwent breast augmentation. 3D volumetric imaging analysis was performed by two independent observers preoperatively and at 6 weeks postoperatively. Simulated volumes were compared to actual implant volume using the Student's t test. Intra-observer reliability was evaluated by measuring internal consistency (Cronbach and 95% confidence interval [CI]) and test-retest reliability (intraclass correlation coefficient [ICC]) from the two observers' calculated volumes. RESULTS Half (n = 11) of the patients received silicone implants and half saline; all were placed in the submuscular plane through an inframammary incision. No difference in volume estimation in preoperative or postoperative images (P = .49 and P = .14; and P = 1.0 and P = .37, in right and left breasts, respectively) was observed. The test-retest reliability between observers was excellent (ICC, 0.98; P < .001) and Cronbach's value (0.99; 95% CI 0.97-0.99; P < .001) demonstrated an excellent correlation. Regarding accuracy, difference in volume estimation between actual and simulated volumes varied between 0 to 106 mL (0 - 30%), with an absolute mean difference of 12.2% (42.5 mL). CONCLUSIONS The Portrait 3D breast imaging system provides a highly reproducible 3D tool for measuring breast volume and simulating breast augmentation. Accuracy of the 3D models can vary up to 30% (mean 12.2%). This variability should be accounted for when using this technology to visually communicate with patients.

[1]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[2]  O. Tepper,et al.  Virtual 3-dimensional modeling as a valuable adjunct to aesthetic and reconstructive breast surgery. , 2006, American journal of surgery.

[3]  B. O. Rogers The first pre- and post-operative photographs of plastic and reconstructive surgery: Contributions of Gurdon Buck (1807–1877) , 2005, Aesthetic Plastic Surgery.

[4]  David Mordaunt,et al.  Four-dimensional breast imaging, part II: clinical implementation and validation of a computer imaging system for breast augmentation planning. , 2011, Aesthetic surgery journal.

[5]  B M Achauer,et al.  Digital photography for the plastic surgeon. , 1998, Plastic and reconstructive surgery.

[6]  Naveen Kumar,et al.  3D Analysis of Breast Augmentation Defines Operative Changes and Their Relationship to Implant Dimensions , 2009, Annals of plastic surgery.

[7]  J M Bland,et al.  Statistical methods for assessing agreement between two methods of clinical measurement , 1986 .

[8]  Michael Chiaramonte,et al.  Clinical Applications of Three‐Dimensional Photography in Breast Surgery , 2002, Plastic and reconstructive surgery.

[9]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[10]  Albert Losken,et al.  Validating Three-Dimensional Imaging of the Breast , 2005, Annals of plastic surgery.

[11]  David H. Mordaunt,et al.  Four-dimensional breast imaging, part I: introduction of a technology-driven, evidence-based approach to breast augmentation planning. , 2011, Aesthetic surgery journal.