Atrial Electrogram Analysis: Antegrade Versus Retrograde

Automatic discrimination between antegrade and retrograde atrial electrograms would prevent endless loop tachycardia and contribute to tachycardia detection algorithms. We tested its feasibility by comparing antegrade and retrograde atrial electrograms in 129 patients at the time of atrial lead implantation. Only unipolar, passive‐fixation, endocardial, right atrial appendage leads were included. The mean antegrade amplitude was 4.2 ± 2.2 mV, and retrograde 2.4 ± 1.5 mV (P < 0.001); the mean antegrade slew rate was 2.6 ± 2.1 mV/ms, and retrograde 1.3 ± 1.1 mV/ms (P < 0.001). Morphology was similar in 84 patients (65%). The antegrade amplitude exceeded the retrograde by 1.0 mV in 67%, and by 0.5 mV in 81% of patients. Morphology and slew rate contributed little to the discriminating power of amplitude alone. Thus, amplitude criteria reliably distinguish antegrade from retrograde atrial activity.

[1]  R Wainwright,et al.  Ideal Atrial Lead Positioning to Detect Retrograde Atrial Depolarization by Digitization and Slope Analysis of the Atrial Electrogram , 1984, Pacing and clinical electrophysiology : PACE.

[2]  S. Furman,et al.  The ventricular endocardial electrogram and pacemaker sensing. , 1977, The Journal of thoracic and cardiovascular surgery.

[3]  L. Rydén,et al.  A Comparison of the Acute and Long‐term Hemodynamic Effects of Ventricular Inhibited and Atrial Synchronous Ventricular Inhibited Pacing , 1982, Circulation.

[4]  H. Herscovici,et al.  Method for Antegrade/Retrograde Conduction Discrimination Using A Standard Atrial Bipolar Lead , 1987, Pacing and clinical electrophysiology : PACE.

[5]  J. Fisher,et al.  Endless Loop Tachycardia in an AV Universal (DDD) Pacemaker , 1982, Pacing and clinical electrophysiology : PACE.

[6]  F. Pannizzo,et al.  Discrimination of antegrade and retrograde atrial depolarization by electrogram analysis. , 1986, American heart journal.

[7]  H. Elmqvist Prevention of Pacemaker Mediated Arrhythmias , 1983, Pacing and clinical electrophysiology : PACE.

[8]  D. Hayes,et al.  Atrio‐Ventricular and Ventriculo‐Atrial Conduction Times in Patients Undergoing Pacemaker Implant , 1983, Pacing and clinical electrophysiology : PACE.

[9]  S Gordon,et al.  Discrimination of Anterograde From Retrograde Atrial Electrograms for Physiologic Pacing , 1988, Pacing and clinical electrophysiology : PACE.

[10]  M. Shenasa,et al.  Effect of verapamil on retrograde atrioventricular nodal conduction in the human heart. , 1983, Journal of the American College of Cardiology.

[11]  S. Furman,et al.  Selective atrial sensing in dual chamber pacemakers eliminates endless loop tachycardia. , 1986, Journal of the American College of Cardiology.

[12]  S. Furman,et al.  The Dynamic Nature of Ventriculoatrial Conduction , 1986, Pacing and clinical electrophysiology : PACE.