Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 days.

A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three consecutive breath exhalations were carried out using selected ion flow tube mass spectrometry (SIFT-MS) on line to the instrument. Sufficient data were obtained to allow meaningful concentration distributions to be obtained for ammonia, acetone, isoprene and ethanol. These showed that the ammonia, acetone and isoprene concentrations exhibited sensibly normal distributions, with coefficients of variation of typically 0.3. Obvious and statistically significant (p < 0.01) differences are apparent in the mean concentrations of these metabolites between the five individuals. The acetaldehyde concentrations were relatively low and close to the instrument detection limit, and the differences between the mean concentrations of the five subjects were not statistically significant (p = 0.4), so distributions were not obtained. The mean concentrations, in parts per billion (ppb), of each metabolite range amongst the five subjects are as follows: ammonia, 422-2389: acetone, 293-870; isoprene, 55-121; ethanol, 27-153; acetaldehyde, 2-5. There are no obvious patterns in the distributions of these particular metabolites for these individuals, except that the ammonia levels were greatest in the breath of the two oldest subjects.

[1]  Tianshu Wang,et al.  Quantification of volatile compounds in the headspace of aqueous liquids using selected ion flow tube mass spectrometry. , 2002, Rapid communications in mass spectrometry : RCM.

[2]  N. Homann Alcohol and upper gastrointestinal tract cancer: the role of local acetaldehyde production , 2001, Addiction biology.

[3]  P. Španěl,et al.  A new 'online' method to measure increased exhaled isoprene in end-stage renal failure. , 2001, Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association.

[4]  A. Jones Measuring and reporting the concentration of acetaldehyde in human breath. , 1995, Alcohol and alcoholism.

[5]  S. Davies,et al.  Quantification of ammonia in human breath by the selected ion flow tube analytical method using H30+ and 02+ precursor ions. , 1998, Rapid communications in mass spectrometry : RCM.

[6]  A. Jones Excretion of low-molecular weight volatile substances in human breath: focus on endogenous ethanol. , 1985, Journal of analytical toxicology.

[7]  G. Freund,et al.  Acetaldehyde concentrations in alveolar air following a standard dose of ethanol in man. , 1965, Journal of lipid research.

[8]  Patrik Španěl,et al.  Application of ion chemistry and the SIFT technique to the quantitative analysis of trace gases in air and on breath , 1996 .

[9]  Z. Zadák,et al.  Determination of isoprene in human expired breath using solid-phase microextraction and gas chromatography-mass spectrometry. , 2000, Journal of chromatography. B, Biomedical sciences and applications.

[10]  P. Španěl,et al.  Trace gases in breath of healthy volunteers when fasting and after a protein-calorie meal: a preliminary study. , 1999, Journal of applied physiology.

[11]  P. Spanĕl,et al.  On-line determination of the deuterium abundance in breath water vapour by flowing afterglow mass spectrometry with applications to measurements of total body water. , 2001, Rapid communications in mass spectrometry : RCM.

[12]  P. Spanĕl,et al.  Influence of water vapour on selected ion flow tube mass spectrometric analyses of trace gases in humid air and breath. , 2000, Rapid communications in mass spectrometry : RCM.

[13]  Patrik Španěl,et al.  Selected ion flow tube – mass spectrometry: detection and real-time monitoring of flavours released by food products , 1999 .

[14]  Yoko Hoshi,et al.  Quantitative evaluation of the relative contribution ratio of cerebral tissue to near-infrared signals in the adult human head: a preliminary study , 2002, Physiological measurement.

[15]  S. Davies,et al.  Quantification of breath isoprene using the selected ion flow tube mass spectrometric analytical method. , 1999, Rapid communications in mass spectrometry : RCM.

[16]  Yufeng Ji,et al.  Concurrent use of H3O+, NO+, and O2+ precursor ions for the detection and quantification of diverse trace gases in the presence of air and breath by selected ion-flow tube mass spectrometry , 2001 .

[17]  J. Cocker,et al.  VALIDATION OF THE SIFT TECHNIQUE FOR TRACE GAS ANALYSIS OF BREATH USING THE SYRINGE INJECTION TECHNIQUE , 1997 .

[18]  David Smith,et al.  On-line, simultaneous quantification of ethanol, some metabolites and water vapour in breath following the ingestion of alcohol. , 2002, Physiological measurement.

[19]  T. Holland,et al.  Analysis of formaldehyde in the headspace of urine from bladder and prostate cancer patients using selected ion flow tube mass spectrometry. , 1999, Rapid communications in mass spectrometry : RCM.

[20]  J. P. Conkle,et al.  Trace composition of human respiratory gas. , 1975, Archives of environmental health.

[21]  P. Rolfe,et al.  The Selected Ion Flow Tube Method for Workplace Analyses of Trace Gases in Air and Breath: Its Scope, Validation, and Applications , 1998 .

[22]  L. T. McGrath,et al.  Breath isoprene during acute respiratory exacerbation in cystic fibrosis. , 2000, The European respiratory journal.

[23]  P. Sobotka,et al.  Expired hydrocarbons in patients with acute myocardial infarction. , 1995, Free radical research.

[24]  P. Španěl,et al.  Quantitative analysis of ammonia on the breath of patients in end-stage renal failure. , 1997, Kidney international.

[25]  A. Manolis,et al.  The diagnostic potential of breath analysis. , 1983, Clinical chemistry.

[26]  D. Kohlmüller,et al.  Is n-pentane really an index of lipid peroxidation in humans and animals? A methodological reevaluation. , 1993, Analytical biochemistry.

[27]  T. Sharkey,et al.  Isoprene synthesis by plants and animals. , 1996, Endeavour.

[28]  T. Risby,et al.  Breath isoprene: temporal changes in respiratory output after exposure to ozone. , 1996, Journal of applied physiology.

[29]  P. Španěl,et al.  The novel selected-ion flow tube approach to trace gas analysis of air and breath. , 1996, Rapid communications in mass spectrometry : RCM.

[30]  D. Lester,et al.  The concentration of apparent endogenous ethanol. , 1962, Quarterly journal of studies on alcohol.

[31]  N. Rogers,et al.  Acetone in breath and blood. , 1977, Transactions of the American Clinical and Climatological Association.

[32]  M. Phillips,et al.  Ion-trap detection of volatile organic compounds in alveolar breath. , 1992, Clinical chemistry.