Resolution recovery in Turbo Spin Echo using segmented Half Fourier acquisition.

Turbo Spin Echo (TSE) is a sequence of choice for obtaining T(2)-weighted images. TSE reduces acquisition time by acquiring several echoes within each TR, at the cost of introducing an exponential weighting in the k-space that leads to a certain image blurring. This is particularly important for short-T(2) structures, which can even disappear if their size in the phase encoding direction is comparable to the degree of blurring. This article suggests the use of a combination of Half Fourier (HF) and segmented (multishot) TSE (sHF-TSE) to recover the original resolution of the SE images. The improved symmetry of the dataset achieved by HF reconstruction is used to increase the resolution of the TSE images. The proposed combination, available in most clinical scanners, reduces the blurring artifact inherent to the TSE sequence without increasing the scan time or the number of acquisitions, but at the cost of a slight reduction of the signal-to-noise ratios (SNR). Qualitative and quantitative results are presented using both numerical simulation and imaging. Significant edge enhancement has been achieved for structures with short T(2), (narrowing of the full width at half maximum [FWHM] up to 45%). The proposed sequence is more sensitive to movement artifacts but has proven to be superior to the conventional TSE for imaging static structures.

[1]  A. Papoulis Circuits and Systems: A Modern Approach , 1980 .

[2]  S. Mirowitz,et al.  T2-weighted MR imaging of the abdomen: fast spin-echo vs conventional spin-echo sequences. , 1994, AJR. American journal of roentgenology.

[3]  J Hennig,et al.  RARE imaging: A fast imaging method for clinical MR , 1986, Magnetic resonance in medicine.

[4]  J. Hogg Magnetic resonance imaging. , 1994, Journal of the Royal Naval Medical Service.

[5]  Partial Fourier MRI: AR models with SVD , 1999, 1999 IEEE Nuclear Science Symposium. Conference Record. 1999 Nuclear Science Symposium and Medical Imaging Conference (Cat. No.99CH37019).

[6]  Sing Lee,et al.  Hepatic malignant tumour versus cavernous haemangioma: differentiation on multiple breath-hold turbo spin-echo MRI sequences with different T2-weighting and T2-relaxation time measurements on a single slice multi-echo sequence. , 2002, Clinical radiology.

[7]  J. Hennig Multiecho imaging sequences with low refocusing flip angles , 1988 .

[8]  N. Müller,et al.  Conventional high-resolution CT versus helical high-resolution MDCT in the detection of bronchiectasis. , 2006, AJR. American journal of roentgenology.

[9]  C. Beaulieu,et al.  Reduction of ringing and blurring artifacts in fast spin‐echo imaging , 1993, Journal of magnetic resonance imaging : JMRI.

[10]  T. Helmberger,et al.  Turbo spin-echo sequences in magnetic resonance imaging of the brain: Physics and applications , 1994, Magnetic Resonance Materials in Physics, Biology and Medicine.

[11]  M Takahashi,et al.  MR cholangiopancreatography using HASTE (half-Fourier acquisition single-shot turbo spin-echo) sequences. , 1996, AJR. American journal of roentgenology.

[12]  J Listerud,et al.  First principles of fast spin echo. , 1992, Magnetic resonance quarterly.

[13]  J C Gore,et al.  The Loss of Small Objects in Variable TE Imaging: Implications for FSE, RARE, and EPI , 1992, Magnetic resonance in medicine.

[14]  J. Hennig,et al.  K-space sampling strategies , 1999, European Radiology.

[15]  R. Edelman,et al.  Magnetic resonance imaging (2) , 1993, The New England journal of medicine.

[16]  Magalie Viallon,et al.  k‐Space filtering in 2D gradient‐echo breath‐hold hyperpolarized 3He MRI: Spatial resolution and signal‐to‐noise ratio considerations , 2002, Magnetic resonance in medicine.

[17]  F. Schick,et al.  Conventional high resolution versus fast T(2)-weighted MR imaging of the heart: assessment of reperfusion induced myocardial injury in an animal model. , 2000, Magnetic resonance imaging.

[18]  G M Bydder,et al.  Magnetic resonance imaging of short T2 components in tissue. , 2003, Clinical radiology.

[19]  J Listerud,et al.  Fast spin-echo imaging of the brain and spine. , 1993, Magnetic resonance quarterly.

[20]  M Takahashi,et al.  Comparison of HASTE and segmented-HASTE sequences with a T2-weighted fast spin-echo sequence in the screening evaluation of the brain. , 1997, AJR. American journal of roentgenology.

[21]  M Takahashi,et al.  Calculation of T2 relaxation time from ultrafast single shot sequences for differentiation of liver tumors: comparison of echo-planar, HASTE, and spin-echo sequences. , 2000, Radiation medicine.

[22]  D. Ortendahl,et al.  Measuring signal-to-noise ratios in MR imaging. , 1989, Radiology.

[23]  F. Jolesz,et al.  CPMG imaging sequences for high field in vivo transverse relaxation studies , 1990, Magnetic resonance in medicine.

[24]  Heinz U Lemke,et al.  Computer-assisted radiology. , 1988, Academic radiology.

[25]  P. J. Keller,et al.  A Nyquist Modulated Echo‐to‐View Mapping Scheme for Fast Spin‐Echo Imaging , 1995, Magnetic resonance in medicine.

[26]  J C Gore,et al.  Factors influencing contrast in fast spin-echo MR imaging. , 1992, Magnetic resonance imaging.

[27]  D. Feinberg,et al.  Halving MR imaging time by conjugation: demonstration at 3.5 kG. , 1986, Radiology.

[28]  D G Mitchell,et al.  Hybrid RARE: Implementations for abdominal MR imaging , 1994, Journal of magnetic resonance imaging : JMRI.