A multiple disk centrifugal pump as a blood flow device

A study of a multiple-disk, shear force, valveless centrifugal pump to determine its suitability as a blood flow device is discussed. A pulsatile version of the Tesla viscous flow turbine was designed by modifying the original steady flow pump concept to produce physiological pressures and flows with the aid of controlling circuitry. Pressures and flows from this pump were compared to a Harvard Apparatus pulsatile piston pump. Both pumps were connected to an artificial circulatory system. Frequency and systolic duration were varied over a range of physiological conditions for both pumps. The results indicated that the Tesla pump, operating in a pulsatile mode, is capable of producing physiologic pressures and flows similar to those produced by the Harvard pump and other pulsatile blood pumps.<<ETX>>

[1]  S. H. Hasinger,et al.  Investigation of a Shear-Force Pump , 1963 .

[2]  E. Bernstein A Centrifugal Pump for Circulatory Assistance , 1979 .

[3]  H Harasaki,et al.  Experimental evaluation of complete electrically powered ventricular assist system. , 1985, Transactions - American Society for Artificial Internal Organs.

[4]  D B Olsen,et al.  Response of the human body to the first permanent implant of the Jarvik-7 Total Artificial Heart. , 1983, Transactions - American Society for Artificial Internal Organs.

[5]  J. Andrade,et al.  Calcification of nontextured implantable blood pumps. , 1981, Transactions - American Society for Artificial Internal Organs.

[6]  M F Lynch,et al.  Centrifugal blood pumping for open heart surgery. , 1978, Minnesota medicine.

[7]  Warren Rice An Analytical and Experimental Investigation of Multiple Disk Pumps and Compressors , 1963 .

[8]  André Kováts Design and performance of centrifugal and axial flow pumps and compressors , 1964 .

[9]  D B Olsen,et al.  Determinants of pannus formation in long-surviving artificial heart calves, and its prevention. , 1981, Transactions - American Society for Artificial Internal Organs.

[10]  R Kiraly,et al.  Comparative evaluation of nonpulsatile and pulsatile cardiac prostheses. , 1980, Transactions - American Society for Artificial Internal Organs.

[11]  C. Mavroudis,et al.  To pulse or not to pulse. , 1978, The Annals of thoracic surgery.

[12]  Y. Nosé The need for a nonpulsatile pumping system. , 1988, Artificial organs.

[13]  D. Harken Mechanical devices to assist the failing heart , 1967 .

[14]  Nicholas P. Cheremisinoff,et al.  Fluid Flow: Pumps Pipes and Channels , 1981 .

[15]  E F Bernstein,et al.  Prolonged pulsatile and nonpulsatile LV bypass with a centrifugal pump. , 1976, Transactions - American Society for Artificial Internal Organs.

[16]  Guy Demoment,et al.  Partial or Total Heart Substitution with a Double-Centrifugal Device — Theoretical and Physiologic Studies , 1979 .

[17]  G Rosenberg,et al.  The compliance problem: a major obstacle in the development of implantable blood pumps. , 1984, Artificial organs.

[18]  G. Rosenberg,et al.  A two and one half year clinical experience with a mechanical left ventricular assist pump in the treatment of profound postoperative heart failure. , 1979, The International journal of artificial organs.

[19]  G Rosenberg,et al.  A cam-type electric motor-driven left ventricular assist device. , 1982, Journal of biomechanical engineering.

[20]  G. Noon,et al.  Development and evaluation of pulsatile roller pump and tubing for cardiac assistance. , 1983, Artificial organs.

[21]  D B Olsen,et al.  Blood pump with a magnetically suspended impeller. , 1985, Transactions - American Society for Artificial Internal Organs.

[22]  E. Hammond,et al.  Clinical use of the total artificial heart. , 1984, The New England journal of medicine.

[23]  R K Jarvik,et al.  The total artificial heart. , 1981, Scientific American.