A continuous description of intervertebral motion by means of spline interpolation of kinematic data extracted by videofluoroscopy.

In vivo analysis of intervertebral kinematics provides useful information about spinal disorders and performance of disk prostheses. Diagnosis of intervertebral instability is based on measurement of abnormal range of segmental motion in sagittal plane through functional flexion-extension radiography; however, this concise measure does not take into account the progression of segmental motion in between flexion and extension extremes. Fluoroscopy can support analysis of intervertebral kinematics during patient's motion with an acceptable X-ray dose. A spline-based method designed for a continuous-time description of intervertebral motion extracted by videofluoroscopy is proposed. Fluoroscopic sagittal sequences of lumbar spine were processed by an automated method based on template matching to track vertebrae. A smoothing spline interpolation of the estimated intervertebral kinematic data was performed and a continuous-time description of segmental rotation and translation was obtained; the smoothing parameter was chosen both to preserve motion and to reduce noise. Concise measurements were extracted by the continuous-time kinematics and compared with standard clinical measurements of intervertebral sagittal rotation and translation. The trajectory of instantaneous center of rotation, never presented before for in vivo spinal segments, was provided and compared with standard measurements of the finite center of rotation. Results showed a good agreement with standard clinical measurements: on average, absolute differences resulted 0.74 degree for sagittal rotation, 0.59 mm for translation and 1.02 mm for the x- and y-position of center of rotation. The proposed method offers an effective technique for the continuous-time description of intervertebral motion, maintaining standard clinical measurements for diagnosis of lumbar instability.

[1]  H. Woltring On optimal smoothing and derivative estimation from noisy displacement data in biomechanics , 1985 .

[2]  D. Kubein-Meesenburg,et al.  Migration of the instantaneous axis of motion during axial rotation in lumbar segments and role of the zygapophysial joints. , 2010, Acta of Bioengineering and Biomechanics.

[3]  M M Panjabi,et al.  Errors in the center and angle of rotation of a joint: an experimental study. , 1982, Journal of biomechanical engineering.

[4]  L. Jennings,et al.  On the use of spline functions for data smoothing. , 1979, Journal of biomechanics.

[5]  H Nägerl,et al.  How do spinal segments move? , 2009, Journal of biomechanics.

[6]  Jack T. Dennerlein,et al.  Comparing polynomial and cubic spline interpolation of segment angles for estimating L5/S1 net moment during symmetric lifting tasks. , 2010, Journal of biomechanics.

[7]  Hendrik Schmidt,et al.  Interaction Between Finite Helical Axes and Facet Joint Forces Under Combined Loading , 2008, Spine.

[8]  M. Panjabi The stabilizing system of the spine. Part II. Neutral zone and instability hypothesis. , 1992, Journal of spinal disorders.

[9]  M J Pearcy,et al.  Instantaneous Axes of Rotation of the Lumbar Intervertebral Joints , 1988, Spine.

[10]  P. Bifulco,et al.  Automatic recognition of vertebral landmarks in fluoroscopic sequences for analysis of intervertebral kinematics , 2006, Medical and Biological Engineering and Computing.

[11]  Paolo Bifulco,et al.  Estimation of out-of-plane vertebra rotations on radiographic projections using CT data: a simulation study. , 2002, Medical engineering & physics.

[12]  C. Reitman,et al.  Radiographic Assessment and Quantitative Motion Analysis of the Cervical Spine After Serial Sectioning of the Anterior Ligamentous Structures , 2007, Spine.

[13]  Thomas R Oxland,et al.  Degenerative mechanics of the lumbar spine. , 2004, The spine journal : official journal of the North American Spine Society.

[14]  M. Pearcy,et al.  Abnormal Motion in Spondylolytic Spondylolisthesis , 2005, Spine.

[15]  M M Panjabi,et al.  Centers and angles of rotation of body joints: a study of errors and optimization. , 1979, Journal of biomechanics.

[16]  R. Hibbeler Engineering Mechanics: Dynamics , 1986 .

[17]  Jennifer M Muggleton,et al.  An objective spinal motion imaging assessment (OSMIA): reliability, accuracy and exposure data , 2006, BMC musculoskeletal disorders.

[18]  J. Cassidy,et al.  Radiologic Diagnosis of Degenerative Lumbar Spinal Instability , 1985, Spine.

[19]  M. Rousseau,et al.  The instant axis of rotation influences facet forces at L5/S1 during flexion/extension and lateral bending , 2006, European Spine Journal.

[20]  J H Challis,et al.  An examination of procedures for determining body segment attitude and position from noisy biomechanical data. , 1995, Medical engineering & physics.

[21]  J M Muggleton,et al.  Automatic location of vertebrae in digitized videofluoroscopic images of the lumbar spine. , 1997, Medical engineering & physics.

[22]  Gung Feng,et al.  Data smoothing by cubic spline filters , 1998, IEEE Trans. Signal Process..

[23]  John A. Hipp,et al.  Threshold Cervical Range-of-Motion Necessary to Detect Abnormal Intervertebral Motion in Cervical Spine Radiographs , 2008, Spine.

[24]  P Bifulco,et al.  Advanced template matching method for estimation of intervertebral kinematics of lumbar spine. , 2011, Medical engineering & physics.

[25]  L. Claes,et al.  The relation between the instantaneous center of rotation and facet joint forces - A finite element analysis. , 2008, Clinical biomechanics.

[26]  I. J. Schoenberg,et al.  SPLINE FUNCTIONS AND THE PROBLEM OF GRADUATION , 1964 .

[27]  T M McLaughlin,et al.  Biomechanical analysis with cubic spline functions. , 1977, Research quarterly.

[28]  M. Panjabi Clinical spinal instability and low back pain. , 2003, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[29]  E. Sariali,et al.  In vivo study of the kinematics in axial rotation of the lumbar spine after total intervertebral disc replacement: long-term results: a 10–14 years follow up evaluation , 2006, European Spine Journal.

[30]  V. Devlin,et al.  Instantaneous Axis of Rotation as a Function of the Three Columns of the Spine , 1992, Spine.

[31]  S. Mercer,et al.  Biomechanics of the cervical spine. I: Normal kinematics. , 2000, Clinical biomechanics.

[32]  J Cholewicki,et al.  Method for measuring vertebral kinematics from videofluoroscopy. , 1991, Clinical biomechanics.

[33]  M. Panjabi,et al.  An Analysis of Errors in Kinematic Parameters Associated with in Vivo Functional Radiographs , 1992, Spine.

[34]  M. Wachowski,et al.  Mechanical properties of cervical motion segments. , 2007 .

[35]  M M Panjabi,et al.  Cervical spine motion in the sagittal plane: kinematic and geometric parameters. , 1982, Journal of Biomechanics.

[36]  D. Andrews,et al.  Determining the optimal system-specific cut-off frequencies for filtering in-vitro upper extremity impact force and acceleration data by residual analysis. , 2011, Journal of biomechanics.

[37]  H. van Mameren,et al.  Cervical Spine Motion in the Sagittal Plane II: Position of Segmental Averaged Instantaneous Centers of Rotation -A Cineradiographic Study , 1992, Spine.

[38]  G. Ferrigno,et al.  Comparison between the more recent techniques for smoothing and derivative assessment in biomechanics , 1992, Medical and Biological Engineering and Computing.

[39]  Jack T Dennerlein,et al.  Interpolation of segment Euler angles can provide a robust estimation of segment angular trajectories during asymmetric lifting tasks. , 2010, Journal of biomechanics.

[40]  R. Balderston,et al.  Evaluation of spinal kinematics following lumbar total disc replacement and circumferential fusion using in vivo fluoroscopy. , 2005, Spine.

[41]  S D Gertzbein,et al.  Determination of a Locus of Instantaneous Centers of Rotation of the Lumbar Disc by Moiré Fringes: A New Technique , 1984, Spine.

[42]  R. Hinrichs,et al.  Endpoint error in smoothing and differentiating raw kinematic data: an evaluation of four popular methods. , 1996, Journal of biomechanics.

[43]  C. Reinsch Smoothing by spline functions , 1967 .

[44]  D. Kubein-Meesenburg,et al.  Axial rotation in the lumbar spine following axial force wrench. , 2009, Journal of physiology and pharmacology : an official journal of the Polish Physiological Society.

[45]  H. Dathe,et al.  Evidence for IHA migration during axial rotation of a lumbar spine segment by using a novel high-resolution 6D kinematic tracking system. , 2004, Journal of biomechanics.

[46]  E. Shwedyk,et al.  P060 Biomechanic signal filtering for dynamic analysis purpose: A quanittative comparison between different methods , 1998 .

[47]  B. McCane,et al.  On calculating the finite centre of rotation for rigid planar motion. , 2005, Medical engineering & physics.

[48]  R. Wilcox An introduction to basic mechanics , 2006 .

[49]  G. Wood Data smoothing and differentiation procedures in biomechanics. , 1982, Exercise and sport sciences reviews.

[50]  J Chen,et al.  The limitations of the instantaneous centre of rotation in joint research. , 1999, Journal of oral rehabilitation.

[51]  Guoan Li,et al.  In-vivo motion characteristics of lumbar vertebrae in sagittal and transverse planes. , 2010, Journal of biomechanics.

[52]  G B Andersson,et al.  The Effect of Disc Degeneration and Facet Joint Osteoarthritis on the Segmental Flexibility of the Lumbar Spine , 2000, Spine.

[53]  李幼升,et al.  Ph , 1989 .

[54]  Yalin Zheng,et al.  Automated segmentation of lumbar vertebrae in digital videofluoroscopic images , 2004, IEEE Transactions on Medical Imaging.

[55]  Sean P. F. Hughes,et al.  Instantaneous Center of Rotation and Instability of the Cervical Spine: A Clinical Study , 1997, Spine.

[56]  Maria Romano,et al.  2D-3D Registration of CT Vertebra Volume to Fluoroscopy Projection: A Calibration Model Assessment , 2010, EURASIP J. Adv. Signal Process..

[57]  R. Wilcox MINI-SYMPOSIUM: BIOMECHANICS FOR THE FRCS ORTH EXAM(i) An introduction to basic mechanics , 2006 .

[58]  Giuseppe Guglielmi,et al.  Lumbar intervertebral instability: a review. , 2007, Radiology.

[59]  Manohar M. Panjabi,et al.  Clinical Biomechanics of the Spine , 1978 .