Bio- and chemiluminescence imaging in analytical chemistry

Bio- and chemiluminescence imaging techniques combine the high sensitivity of bio- and chemiluminescence detection with the ability of current light imaging devices to localize and quantify light emission down to the single-photon level. These techniques have been successfully exploited for the development of sensitive analytical methods relying on the evaluation of the spatial distribution of the light emitted from a target sample. In this paper, we report on recent applications of bio- and chemiluminescence imaging for in vitro and in vivo assays, including: quantitative assays performed in various analytical formats, such as microtiter plates, microarrays and miniaturized analytical devices, used in the pharmaceutical, clinical, diagnostic and environmental fields; luminescence imaging microscopy based on enzymatic, immunohistochemical and in situ hybridization reactions for the localization of metabolites, enzymes, antigens and gene sequences in cells and tissues; whole-body luminescence imaging in live animals for evaluating biological and pathological processes and for pharmacological studies.

[1]  S. Moncada,et al.  Visualisation of nitric oxide released by nerve stimulation , 1997, Journal of neuroscience research.

[2]  C. Guillermet,et al.  Enhanced chemiluminescence: a high-sensitivity detection system for in situ hybridization and immunohistochemistry. , 1993, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[3]  Lu Zhang,et al.  A protein chip system for parallel analysis of multi-tumor markers and its application in cancer detection. , 2004, Anticancer research.

[4]  A. Roda,et al.  Sensitive Chemiluminescence In Situ Hybridization for the Detection of Human Papillomavirus Genomes in Biopsy Specimens , 1997, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[5]  Aldo Roda,et al.  Microtiter format for simultaneous multianalyte detection and development of a PCR-chemiluminescent enzyme immunoassay for typing human papillomavirus DNAs. , 2002, Clinical chemistry.

[6]  Ruo-Pan Huang,et al.  Detection of Multiple Cytokines by Protein Arrays from Cell Lysate and Tissue Lysate , 2003, Clinical chemistry and laboratory medicine.

[7]  A. Cavalli,et al.  Synthesis and screening for antiacetylcholinesterase activity of (1-benzyl-4-oxopiperidin-3-ylidene)methylindoles and -pyrroles related to donepezil. , 2001, Journal of medicinal chemistry.

[8]  P. Iversen,et al.  Validation of a Noninvasive, Real-Time Imaging Technology Using Bioluminescent Escherichia coli in the Neutropenic Mouse Thigh Model of Infection , 2001, Antimicrobial Agents and Chemotherapy.

[9]  S. Moncada,et al.  Visualisation of nitric oxide generated by activated murine macrophages. , 1996, Biochemical and biophysical research communications.

[10]  D. A. Morales,et al.  Multiplexed screening assay for mRNA combining nuclease protection with luminescent array detection. , 2002, Assay and drug development technologies.

[11]  S. Gambhir,et al.  Molecular Imaging of Cardiac Cell Transplantation in Living Animals Using Optical Bioluminescence and Positron Emission Tomography , 2003, Circulation.

[12]  W. Baeyens,et al.  Chemiluminescent image detection of haptoglobin phenotyping after polyacrylamide gel electrophoresis. , 2004, Analytical chemistry.

[13]  M Musiani,et al.  Chemiluminescent immunoperoxidase assay for the dot blot hybridization detection of Parvovirus B19 DNA using a low light imaging device. , 1996, Analytical biochemistry.

[14]  T. Schroeder,et al.  Metabolic mapping with bioluminescence: basic and clinical relevance. , 2002, Biomolecular engineering.

[15]  S. Walenta,et al.  Geographical mapping of metabolites in biological tissue with quantitative bioluminescence and single photon imaging , 1993, The Histochemical Journal.

[16]  U. Isacsson,et al.  Chemiluminescence in analytical chemistry , 1974 .

[17]  B. Danielsson,et al.  Optimization of a charge coupled device imaging enzyme linked immuno sorbent assay and supports for the simultaneous determination of multiple 2,4-D samples , 1997 .

[18]  Kevin P. Francis,et al.  Monitoring Bioluminescent Staphylococcus aureusInfections in Living Mice Using a Novel luxABCDEConstruct , 2000, Infection and Immunity.

[19]  A. Roda,et al.  Chemiluminescent low-light imaging of biospecific reactions on macro- and microsamples using a videocamera-based luminograph. , 1996, Analytical chemistry.

[20]  A. Roda,et al.  Prenatal Diagnosis of Parvovirus B19-Induced Hydrops Fetalis by Chemiluminescence In Situ Hybridization , 1999, Journal of Clinical Microbiology.

[21]  George McNamara,et al.  Dynamic tracking of human hematopoietic stem cell engraftment using in vivo bioluminescence imaging. , 2003, Blood.

[22]  Aldo Roda,et al.  Bioluminescence and chemiluminescence in drug screening , 2003, Analytical and bioanalytical chemistry.

[23]  Reinhard Niessner,et al.  Automated microarray system for the simultaneous detection of antibiotics in milk. , 2004, Analytical chemistry.

[24]  Christopher H Contag,et al.  Technoreview: In vivo bioluminescence imaging for integrated studies of infection , 2004, Cellular microbiology.

[25]  I. Bronstein,et al.  Imaging of chemiluminescent signals with cooled CCD camera systems. , 1994, Journal of bioluminescence and chemiluminescence.

[26]  A. Söling,et al.  Bioluminescence imaging in vivo – application to cancer research , 2003, Expert opinion on biological therapy.

[27]  R. Huang,et al.  Detection of multiple proteins in an antibody-based protein microarray system. , 2001, Journal of immunological methods.

[28]  Robbert Créton,et al.  Calcium imaging with chemiluminescence , 1999, Microscopy research and technique.

[29]  L. Jaffe,et al.  Chemiluminescence microscopy as a tool in biomedical research. , 2001, BioTechniques.

[30]  A. Roda,et al.  In situ hybridization and immunohistochemistry with enzyme-triggered chemiluminescent probes. , 2000, Methods in enzymology.

[31]  R. Kranz,et al.  Chemiluminescent-based methods to detect subpicomole levels of c-type cytochromes. , 2003, Analytical biochemistry.

[32]  D. Piwnica-Worms,et al.  Technoreview: Molecular imaging of host–pathogen interactions in intact small animals , 2004, Cellular microbiology.

[33]  M. Montero,et al.  Measuring [Ca2+] in the endoplasmic reticulum with aequorin. , 2002, Cell calcium.

[34]  S. Moncada,et al.  Visualization of nitric oxide formation in cell cultures and living tissue. , 1999, Acta physiologica Scandinavica.

[35]  P. R. Contag,et al.  Whole-animal cellular and molecular imaging to accelerate drug development. , 2002, Drug discovery today.

[36]  E. Brambilla,et al.  Comparison of 35S and chemiluminescence for HPV in situ hybridization in carcinoma cell lines and on human cervical intraepithelial neoplasia. , 1996, The journal of histochemistry and cytochemistry : official journal of the Histochemistry Society.

[37]  Qian Zhang,et al.  Optical imaging: bacteria, viruses, and mammalian cells encoding light-emitting proteins reveal the locations of primary tumors and metastases in animals , 2003, Analytical and bioanalytical chemistry.

[38]  Aldo Roda,et al.  SENSITIVE DETERMINATION OF URINARY MERCURY(II) BY A BIOLUMINESCENT TRANSGENIC BACTERIA-BASED BIOSENSOR , 2001 .

[39]  H. Köster,et al.  Applications of dioxetane chemiluminescent probes to molecular biology , 1990 .

[40]  A. Gasbarrini,et al.  Chemiluminescent real time imaging of post-ischemic oxygen free radicals formation in livers isolated from young and old rats. , 1998, Free radical biology & medicine.

[41]  G Aicardi,et al.  Chemiluminescence imaging in bioanalysis. , 1998, Journal of pharmaceutical and biomedical analysis.

[42]  P. Cutler Protein arrays: The current state‐of‐the‐art , 2003, Proteomics.

[43]  A. Roda,et al.  Chemiluminescent imaging of enzyme-labeled probes using an optical microscope-videocamera luminograph. , 1998, Analytical biochemistry.

[44]  S. Orencole,et al.  Array-based ELISAs for high-throughput analysis of human cytokines. , 2001, BioTechniques.

[45]  G. Bondjers,et al.  Mapping of ATP, Glucose, Glycogen, and Lactate Concentrations Within the Arterial Wall , 2003, Arteriosclerosis, thrombosis, and vascular biology.

[46]  B. J. Cheek,et al.  Chemiluminescence detection for hybridization assays on the flow-thru chip, a three-dimensional microchannel biochip. , 2001, Analytical chemistry.

[47]  A. Roda,et al.  Chemiluminescent in situ hybridization for the detection of cytomegalovirus DNA. , 1996, The American journal of pathology.

[48]  Knox Van Dyke,et al.  Luminescence biotechnology : instruments and applications , 2001 .

[49]  Michael Bachmann,et al.  Bioluminescent indicators for in vivo measurements of gene expression , 2002 .