Hardware implementation of a hybrid protection scheme for bipolar HVDC line

Implementation of a hybrid protection scheme for bipolar HVDC line with field-programmable gate array (FPGA) is described in this paper. The protection scheme amalgamates a traveling wave protection unit, a boundary protection unit and a lightning unit. Stationary wavelet transform (SWT) and its wavelet modulus maxima are used to remove noise and represent useful traveling wave signal. Boundary protection based on SWT is used jointly with traveling wave protection to distinguish internal faults from external faults. Lightning unit is used to distinguish non-fault transients and to identify the faulty pole. Xilinx XtremeDSP Development Kit-4 is employed for prototyping the relay, with coding done using Xilinx System Generator and AccelDSP.

[1]  Xiaolei Liu,et al.  Real-Time Implementation of a Hybrid Protection Scheme for Bipolar HVDC Line Using FPGA , 2011, IEEE Transactions on Power Delivery.

[2]  H. Elahi,et al.  Modeling guidelines for fast front transients , 1996 .

[3]  O.P. Malik,et al.  Hybrid Traveling Wave/Boundary Protection for Monopolar HVDC Line , 2009, IEEE Transactions on Power Delivery.

[4]  Edward Wilson Kimbark,et al.  Direct current transmission. , 1971 .

[5]  E. Dirks,et al.  Hardware and software implementation of a travelling wave based protection relay , 2005, IEEE Power Engineering Society General Meeting, 2005.

[6]  M. Ando,et al.  Development and Field-data Evaluation of Single-end Fault Locator for Two-Terminal HVDC Transmission Lines, Part I: Data Collection System and Field Data , 1985, IEEE Power Engineering Review.

[7]  Neville R. Watson,et al.  Modeling of bipolar HVDC links in the harmonic domain , 2000 .

[8]  Z. Q. Bo,et al.  A new non-communication protection technique for transmission lines , 1998 .

[9]  Wang Gang,et al.  Transient Based Protection for HVDC Lines Using Wavelet-Multiresolution Signal Decomposition , 2005, 2005 IEEE/PES Transmission & Distribution Conference & Exposition: Asia and Pacific.

[10]  Paul M. Anderson Power System Protection , 1998 .

[11]  Yaozhong Ge,et al.  Surge impedance relay , 2005, IEEE Transactions on Power Delivery.

[12]  O.P. Malik,et al.  Hybrid traveling wave/boundary protection for bipolar HCDC line , 2009, 2009 IEEE Power & Energy Society General Meeting.

[13]  P. F. Gale,et al.  Travelling wave fault locator experience on Eskom's transmission network , 2001 .

[14]  S. P. Valsan,et al.  Protective relaying for power transformers using field programmable gate array , 2008 .

[15]  O.P. Malik,et al.  Stationary Wavelet Transform Based HVDC Line Protection , 2007, 2007 39th North American Power Symposium.

[16]  Narain G. Hingorani Transient Overvoltage on a Bipolar HVDC Overhead Line Caused by DC Line Faults , 1970 .

[17]  O.P. Malik,et al.  Advanced simulation tool for relay testing , 2008, 2008 40th North American Power Symposium.