Theoretical background and conceptual solution for depth perception and eye-hand coordination problems in laparoscopic surgery

SummaryThe indirect method of observation and manipulation in laparoscopic surgery complicates the surgeon's depth perception and impairs his/her eye-hand coordination. Depth perception problems are due to misfits in accommodation and convergence, absence of shadows in endoscopic camera pictures and absence of stereo-vision and movement parallax. Eye-hand coordination problems are caused by the distant location of the monitor and by the fact that the surgeon's hand movements are rotated, mirrored and amplified when they appear on the monitor. These effects are very confusing, especially for trainee laparoscopic surgeons and require a long and intensive training period to overcome. This paper gives a theoretical background of the depth perception and eye-hand coordination problems. A technical concept of an endoscope positioning system is described that compensates misorientations by using a flexible 90° endoscope. Movement parallax is achieved using a motorised endoscope positioner controlled by the surge...

[1]  A. Cuschieri,et al.  Operative Manual of Endoscopic Surgery 2 , 1994, Springer Berlin Heidelberg.

[2]  Marc O. Schurr,et al.  Human sense of vision: a guide to future endoscopic imaging systems , 1996 .

[3]  Jenny Dankelman,et al.  Man-machine aspects of minimally invasive surgery , 1998, Annu. Rev. Control..

[4]  P. A. Finlay,et al.  Controlling the movement of a surgical laparoscope , 1995 .

[5]  Alfred Cuschieri,et al.  Visual display technology for endoscopic surgery , 1996 .

[6]  A. Cuschieri,et al.  Comparison of direct vision and electronic two‐ and three‐dimensional display systems on surgical task efficiency in endoscopic surgery , 1995, The British journal of surgery.

[7]  N. J. Wade,et al.  Frames of reference in vision , 1996 .

[8]  Ryutarou Ohbuchi,et al.  Merging virtual objects with the real world: seeing ultrasound imagery within the patient , 1992, SIGGRAPH.

[9]  A. Cuschieri,et al.  Task performance in endoscopic surgery is influenced by location of the image display. , 1998, Annals of surgery.

[10]  A Cuschieri,et al.  Technological aspects of minimal access surgery , 1997, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[11]  Klaus Radermacher,et al.  Stereoscopic Visualization in Endoscopic Surgery: Problems, Benefits, and Potentials , 1997, Presence: Teleoperators & Virtual Environments.

[12]  Lawrence W. Stark,et al.  Sensing and Manipulation Problems in Endoscopic Surgery: Experiment, Analysis, and Observation , 1993, Presence: Teleoperators & Virtual Environments.

[13]  P. Breedvel,et al.  Observation, manipulation, and eye-hand coordination problems in minimally invasive surgery , 1997 .

[14]  J. Gibson The Ecological Approach to Visual Perception , 1979 .

[15]  F Mosca,et al.  Three-dimensional versus two-dimensional video system for the trained endoscopic surgeon and the beginner. , 1994, Endoscopic surgery and allied technologies.

[16]  Alfred Cuschieri,et al.  Developing Technology for Suspended Imaging for Minimal Access Surgery , 1997, Seminars in laparoscopic surgery.

[17]  C. J. Overbeeke,et al.  Depth perception in laparoscopy through perception-action coupling , 1998 .

[18]  F. Voorhorst Affording Action; Implementing Perception-Action coupling for Endoscopy , 1998 .

[19]  Russell H. Taylor,et al.  Computer-Integrated Surgery: Technology and Clinical Applications , 1995 .

[20]  A. Cuschieri,et al.  Randomised study of influence of two-dimensional versus three-dimensional imaging on performance of laparoscopic cholecystectomy , 1998, The Lancet.

[21]  T. Motoki,et al.  Present status of three-dimensional television research , 1995, Proc. IEEE.