Effect of actuation sequence on flow rates of peristaltic micropumps with PZT actuators

Many biomedical applications require the administration of drugs at a precise and preferably programmable rate. The flow rate generated by the peristaltic micropumps used in such applications depends on the actuation sequence. Accordingly, the current study performs an analytical and experimental investigation to determine the correlation between the dynamic response of the diaphragms in the micropump and the actuation sequence. A simple analytical model of a peristaltic micropump is established to analyze the shift in the resonant frequency of the diaphragms caused by the viscous damping effect. The analytical results show that this damping effect increases as the oscillation frequency of the diaphragm increases. A peristaltic micropump with three piezoelectric actuators is fabricated on a silicon substrate and is actuated using 2-, 3-, 4- and 6-phase actuation sequences via a driving system comprising a microprocessor and a phase controller. A series of experiments is conducted using de-ionized water as the working fluid to determine the diaphragm displacement and the flow rates induced by each of the different actuation sequences under phase frequencies ranging from 50 Hz to 1 MHz. The results show that the damping effect of actuation sequences influences diaphragm resonant frequency, which in turn affects the profiles of flow rates.

[1]  Nam-Trung Nguyen,et al.  MEMS-Micropumps: A Review , 2002 .

[2]  L. Jang,et al.  Peristaltic piezoelectric micropump system for biomedical applications , 2007, Biomedical microdevices.

[3]  Dennis L. Polla,et al.  Design and simulation of an implantable medical drug delivery system using microelectromechanical systems technology , 2001 .

[4]  Ling-Sheng Jang,et al.  Peristaltic micropump system with piezoelectric actuators , 2007 .

[5]  Dae-Sik Lee,et al.  Fabrication and characterization of a bidirectional valveless peristaltic micropump and its application to a flow-type immunoanalysis , 2004 .

[6]  Peter Enoksson,et al.  A Valve-Less Diffuser Micropump for Microfluidic Analytical Systems , 2001 .

[7]  Stephen P. Timoshenko,et al.  Vibration problems in engineering , 1928 .

[8]  Mark G. Allen,et al.  Fluid micropumps based on rotary magnetic actuators , 1995, Proceedings IEEE Micro Electro Mechanical Systems. 1995.

[9]  A. D. Young,et al.  An Introduction to Fluid Mechanics , 1968 .

[10]  W. Janna,et al.  Introduction to Fluid Mechanics , 2012 .

[11]  Jun Xie,et al.  Surface micromachined electrostatically actuated micro peristaltic pump. , 2004, Lab on a chip.

[12]  Juan G. Santiago,et al.  A review of micropumps , 2004 .

[13]  Yi-Chung Shu,et al.  Shape-Memory Micropumps , 2002 .

[14]  Olivier Français,et al.  Dynamic simulation of an electrostatic micropump with pull-in and hysteresis phenomena , 1998 .

[15]  J. J. Carr,et al.  Introduction to Biomedical Equipment Technology , 1981 .

[16]  Alan G. R. Evans,et al.  Investigation for the operation of an integrated peristaltic micropump , 2004 .

[17]  J. G. Smits Piezoelectric micropump with three valves working peristaltically , 1990 .

[18]  Liwei Lin,et al.  Active microfluidic mixer and gas bubble filter driven by thermal bubble micropump , 2002 .

[19]  James S. Wilkinson,et al.  Design and theoretical evaluation of a novel microfluidic device to be used for PCR , 2003 .