Simulation of blood flow into the popliteal artery to explain the effect of peripheral arterial disease: Investigation the conditions and effects of different foot states during the daily activity of the patient

BACKGROUND AND OBJECTIVE Peripheral artery disease, one type of atherosclerosis, is a common medical condition in the world that results from plaque build-up in the peripheral blood vessels. The symptoms of this disease are the senses of pain and weakness in outer muscles. METHODS The artery under consideration is called the popliteal artery. In this model, the blood flow is considered as pulsating. Therefore the inlet boundary condition is taken as unsteady velocity, and the outlet boundary condition is taken the outflow. The inlet boundary condition represents the increasing systole flow and the decreasing diastole flow, which occur naturally in blood flow. Systolic flow occurs when the heart contracts and pumps blood into the arteries. The inlet blood flow is in the form of a sine-cosine parabolic profile. RESULTS The artery bends from the middle at an angle of 45°. As the bending of the artery begins, the flow field also takes a bent form. At this point, the flow bends from the outside of the top wall and enfolds the bottom wall in its bending. For different periods, the popliteal flow is closer to the lower bend when the inlet velocity is more significant. While the top wall experiences a low-intensity region along the bend, the bottom wall experiences the same effect just before and after the bend. As the blood flows along the bend, the flow path becomes significantly curved near the bend, similar to the model. The clotted artery exhibits a large increase in flow due to a reduction in the cross-section as a result of the clotting in half of the artery. The flow before the clotting is not considerably different from the main model of the straight artery. CONCLUSIONS Like shear stress, the pressure drop has a linear relationship with the blood HCT and, hence, the viscosity. The pressure drop decreases with the inlet velocity reaching its maximum value and then increases with the start of the acceleration reduction in the second and third-time steps. This indicates that the pressure drop has a stronger relationship with the acceleration than the inlet velocity.

[1]  M. Salavati‐Niasari,et al.  Gd2ZnMnO6/ZnO nanocomposites: Green sol-gel auto-combustion synthesis, characterization and photocatalytic degradation of different dye pollutants in water , 2020 .

[2]  Y. Wolf,et al.  Size of normal and aneurysmal popliteal arteries: a duplex ultrasound study. , 2006, Journal of vascular surgery.

[3]  D. P. Giddens,et al.  Turbulence measurements in a constricted tube , 1980, Journal of Fluid Mechanics.

[4]  A. Nicolaides,et al.  Effect of posture on popliteal artery hemodynamics. , 2000, Archives of surgery.

[5]  William Francis Ganong,et al.  Review of Medical Physiology , 1969 .

[6]  A. Abbaspourrad,et al.  A novel electrochemical epinine sensor using amplified CuO nanoparticles and an-hexyl-3-methylimidazolium hexafluorophosphate electrode , 2019, New Journal of Chemistry.

[7]  Davood Toghraie,et al.  Computational investigation of stenosis in curvature of coronary artery within both dynamic and static models , 2019, Comput. Methods Programs Biomed..

[8]  R Guidoin,et al.  Low Reynolds number turbulence modeling of blood flow in arterial stenoses. , 1998, Biorheology.

[9]  Steven H Frankel,et al.  Numerical modeling of pulsatile turbulent flow in stenotic vessels. , 2003, Journal of biomechanical engineering.

[10]  Ender A. Finol,et al.  Compliant biomechanics of abdominal aortic aneurysms: A fluid-structure interaction study , 2007 .

[11]  Loke Kok Foong,et al.  Numerical investigation of non-Newtonian blood flow within an artery with cone shape of stenosis in various stenosis angles , 2020, Comput. Methods Programs Biomed..

[12]  D. Ku,et al.  A 3-D thin-wall model with fluid–structure interactions for blood flow in carotid arteries with symmetric and asymmetric stenoses , 1999 .

[13]  D. Giddens,et al.  Post-stenotic core flow behavior in pulsatile flow and its effects on wall shear stress. , 1990, Journal of biomechanics.

[14]  Loke Kok Foong,et al.  Analysis and manegement of laminar blood flow inside a cerebral blood vessel using a finite volume software program for biomedical engineering , 2020, Comput. Methods Programs Biomed..

[15]  Mehdi Shahedi Asl,et al.  Co-reinforcing of mullite-TiN-CNT composites with ZrB2 and TiB2 compounds , 2019, Ceramics International.

[16]  Barbara M. Johnston,et al.  Non-Newtonian blood flow in human right coronary arteries: steady state simulations. , 2004, Journal of biomechanics.

[17]  Davood Toghraie,et al.  Molecular dynamics simulation of Doxorubicin loading with N-isopropyl acrylamide carbon nanotube in a drug delivery system , 2019, Comput. Methods Programs Biomed..

[18]  S. A. Ahmed,et al.  Velocity measurements in steady flow through axisymmetric stenoses at moderate Reynolds numbers. , 1983, Journal of biomechanics.

[19]  Young I Cho,et al.  Effect of blood viscosity on oxygen transport in residual stenosed artery following angioplasty. , 2008, Journal of biomechanical engineering.

[20]  Vinod K. Gupta,et al.  A new epirubicin biosensor based on amplifying DNA interactions with polypyrrole and nitrogen-doped reduced graphene: Experimental and docking theoretical investigations , 2019, Sensors and Actuators B: Chemical.

[21]  S. Agarwal,et al.  Voltammetric amplified platform based on ionic liquid/NiO nanocomposite for determination of benserazide and levodopa , 2019, Journal of Molecular Liquids.

[22]  Yasin Orooji,et al.  Systematic activation of potassium peroxydisulfate with ZIF-8 via sono-assisted catalytic process: Mechanism and ecotoxicological analysis , 2020, Journal of Molecular Liquids.

[23]  Prashanta Kumar Mandal,et al.  Mathematical model of pulsatile blood flow in a distensible aortic bifurcation subject to body acceleration , 2000 .

[24]  M. Salavati‐Niasari,et al.  Green synthesis using cherry and orange juice and characterization of TbFeO3 ceramic nanostructures and their application as photocatalysts under UV light for removal of organic dyes in water , 2020 .

[25]  S. Joo,et al.  Cerium doped magnetite nanoparticles for highly sensitive detection of metronidazole via chemiluminescence assay. , 2020, Spectrochimica acta. Part A, Molecular and biomolecular spectroscopy.

[26]  Spencer J. Sherwin,et al.  Three-dimensional instabilities and transition of steady and pulsatile axisymmetric stenotic flows , 2005, Journal of Fluid Mechanics.

[27]  R. Soltani,et al.  In-situ electro-generation and activation of hydrogen peroxide using a CuFeNLDH-CNTs modified graphite cathode for degradation of cefazolin. , 2020, Journal of Environmental Management.

[28]  Mehdi Shahedi Asl,et al.  Preparation of mullite-TiB2-CNTs hybrid composite through spark plasma sintering , 2019, Ceramics International.

[29]  W. Yan,et al.  Thermal-hydraulic analysis for alumina/water nanofluid inside a mini-channel heat sink with latent heat cooling ceiling-An experimental study , 2020, International Communications in Heat and Mass Transfer.

[30]  Nathan M. Wilson,et al.  Methods for Quantifying Three-Dimensional Deformation of Arteries due to Pulsatile and Nonpulsatile Forces: Implications for the Design of Stents and Stent Grafts , 2008, Annals of Biomedical Engineering.

[31]  E. Ghasali,et al.  Development of Metal Matrix Composites and Nanocomposites Via Double-Pressing Double-Sintering (DPDS) Method , 2020 .

[32]  W. Gedroyc,et al.  Curvature and tortuosity of the superficial femoral artery: a possible risk factor for peripheral arterial disease. , 2006, Journal of applied physiology.

[33]  H. Udaykumar,et al.  Application of large-eddy simulation to the study of pulsatile flow in a modeled arterial stenosis. , 2001, Journal of biomechanical engineering.

[34]  D. Saloner,et al.  Numerical analysis of flow through a severely stenotic carotid artery bifurcation. , 2002, Journal of biomechanical engineering.

[35]  B. Sonesson,et al.  Factors predicting the diameter of the popliteal artery in healthy humans. , 1998, Journal of Vascular Surgery.

[36]  Klaus Bremhorst,et al.  A Modified Form of the k-ε Model for Predicting Wall Turbulence , 1981 .

[37]  Davood Toghraie,et al.  Blood flow analysis inside different arteries using non-Newtonian Sisko model for application in biomedical engineering , 2020, Comput. Methods Programs Biomed..

[38]  Thong-See Lee,et al.  Numerical simulation of turbulent flow through series stenoses , 2003 .

[39]  Davood Toghraie,et al.  Computer modeling of pulsatile blood flow in elastic artery using a software program for application in biomedical engineering , 2020, Comput. Methods Programs Biomed..

[40]  M. Taher,et al.  A nanostructure voltammetric platform amplified with ionic liquid for determination of tert-butylhydroxyanisole in the presence kojic acid , 2019, Journal of Food Measurement and Characterization.

[41]  Danny Bluestein,et al.  Vortex Shedding in Steady Flow Through a Model of an Arterial Stenosis and Its Relevance to Mural Platelet Deposition , 1999, Annals of Biomedical Engineering.

[42]  Ugo Piomelli,et al.  Turbulence Models in Pulsating Flows , 2001 .

[43]  D. C. Wilcox,et al.  Turbulence-Model Predictions for Turbulent Boundary Layers , 1974 .

[44]  Jiyuan Tu,et al.  Modeling of non-Newtonian blood flow through a stenosed artery incorporating fluid-structure interaction , 2007 .

[45]  H. Karimi-Maleh,et al.  3D reduced graphene oxide/FeNi3-ionic liquid nanocomposite modified sensor; an electrical synergic effect for development of tert-butylhydroquinone and folic acid sensor , 2019, Composites Part B: Engineering.

[46]  Davood Toghraie,et al.  The effect of the second excitation frequency mode under different conditions on the fluid streaming and microparticles acoustophoresis with the aim of separating biological cells , 2020, Comput. Methods Programs Biomed..

[47]  Mehdi Shahedi Asl,et al.  Effects of ZrB2 reinforcement on microstructure and mechanical properties of a spark plasma sintered mullite-CNT composite , 2019, Ceramics International.

[48]  P. Spalart A One-Equation Turbulence Model for Aerodynamic Flows , 1992 .

[49]  Charles A. Taylor,et al.  A coupled momentum method for modeling blood flow in three-dimensional deformable arteries , 2006 .

[50]  Prashanta Kumar Mandal,et al.  Two-dimensional blood flow through tapered arteries under stenotic conditions , 2000 .