Capacitive Sensing for Monitoring Stent Patency in the Central Airway

Central airway obstruction (CAO) is a respiratory disorder characterized by the blockage of the trachea and/or the main bronchi that can be life-threatening. Airway stenting is a palliative procedure for CAO commonly used given its efficacy. However, mucus impaction, secretion retention, and granulation tissue growth are known complications that can counteract the stent’s benefits. To prevent these situations, patients are routinely brought into the hospital to check stent patency, incurring a burden for the patient and the health care system, unnecessarily when no problems are found. In this paper, we introduce a capacitive sensor embedded in a stent that can detect solid and colloidal obstructions in the stent, as such obstructions alter the capacitor’s dielectric relative permittivity. In the case of colloidal obstructions (e.g., mucus), volumes as low as 0.1 ml can be detected. Given the small form factor of the sensor, it could be adapted to a variety of stent types without changing the standard bronchoscopy insertion method. The proposed system is a step forward in the development of smart airway stents that overcome the limitations of current stenting technology.Clinical Relevance— This establishes the foundation for smart stent technology to monitor stent patency as an alternative to rutinary bronchoscopies.

[1]  Koichiro Uto,et al.  Functional biomaterials towards flexible electronics and sensors. , 2018, Biosensors & bioelectronics.

[2]  Minoru Sasaki,et al.  A Wearable Capacitive Sensor for Monitoring Human Respiratory Rate , 2013 .

[3]  K. Triyana,et al.  Analytical solutions for capacitance of a semi-cylindrical capacitive sensor , 2016 .

[4]  Guang Zhang,et al.  Emerging Wearable Medical Devices towards Personalized Healthcare , 2013, BODYNETS.

[5]  L. Yarmus,et al.  Airway stent complications: the role of follow-up bronchoscopy as a surveillance method. , 2017, Journal of thoracic disease.

[6]  E. Kan,et al.  Wearable radio-frequency sensing of respiratory rate, respiratory volume, and heart rate , 2020, npj Digital Medicine.

[7]  F. Vogenberg,et al.  Personalized medicine: part 1: evolution and development into theranostics. , 2010, P & T : a peer-reviewed journal for formulary management.

[8]  Ramesh Jain,et al.  Respiration rate and volume measurements using wearable strain sensors , 2019, npj Digital Medicine.

[9]  Andrea Aliverti,et al.  Wearable technology: role in respiratory health and disease , 2017, Breathe.

[10]  H. Saka,et al.  Airway stenting: Technological advancements and its role in interventional pulmonology. , 2020, Respirology.

[11]  M. Tewari,et al.  Real-time, personalized medicine through wearable sensors and dynamic predictive modeling: a new paradigm for clinical medicine. , 2020, Current opinion in systems biology.

[12]  Sagarika Pal,et al.  Design, Development and Testing of a Semi Cylindrical Capacitive Array Type Liquid Interface Level Sensor , 2011, Int. J. Meas. Technol. Instrum. Eng..

[13]  A C Mehta,et al.  Airway stents. , 1999, Clinics in chest medicine.

[14]  Kholod Alamoudi,et al.  Flexible and biocompatible high-performance solid-state micro-battery for implantable orthodontic system , 2017, npj Flexible Electronics.

[15]  D. Zheng,et al.  Fabrication and Evaluation of a Novel Non-Invasive Stretchable and Wearable Respiratory Rate Sensor Based on Silver Nanoparticles Using Inkjet Printing Technology , 2019, Polymers.

[16]  Cheng-Ta Chiang,et al.  A Semicylindrical Capacitive Sensor With Interface Circuit Used for Flow Rate Measurement , 2006, IEEE Sensors Journal.

[17]  F. Bhora,et al.  Stents for airway strictures: selection and results. , 2017, Journal of thoracic disease.

[18]  R. Karmy-Jones,et al.  Airway stenting for malignant and benign tracheobronchial stenosis. , 2003, The Annals of thoracic surgery.