Frequency and fundamental signal measurement algorithms for distributed control and protection applications

Increasing penetration of distributed generation within electricity networks leads to the requirement for cheap, integrated, protection and control systems. To minimise cost, algorithms for the measurement of AC voltage and current waveforms can be implemented on a single microcontroller, which also carries out other protection and control tasks, including communication and data logging. This limits the frame rate of the major algorithms, although analogue to digital converters (ADCs) can be oversampled using peripheral control processors on suitable microcontrollers. Measurement algorithms also have to be tolerant of poor power quality, which may arise within grid-connected or islanded (e.g. emergency, battlefield or marine) power system scenarios. This study presents a 'Clarke-FLL hybrid' architecture, which combines a three-phase Clarke transformation measurement with a frequency-locked loop (FLL). This hybrid contains suitable algorithms for the measurement of frequency, amplitude and phase within dynamic three-phase AC power systems. The Clarke-FLL hybrid is shown to be robust and accurate, with harmonic content up to and above 28% total harmonic distortion (THD), and with the major algorithms executing at only 500 samples per second. This is achieved by careful optimisation and cascaded use of exact-time averaging techniques, which prove to be useful at all stages of the measurements: from DC bias removal through low-sample-rate Fourier analysis to sub-harmonic ripple removal. Platform-independent algorithms for three-phase nodal power flow analysis are benchmarked on three processors, including the Infineon TC1796 microcontroller, on which only 10% of the 2000 mus frame time is required, leaving the remainder free for other algorithms.

[1]  Andrew J. Roscoe Measurement, control and protection of microgrids at low frame rates supporting security of supply , 2009 .

[2]  M. Castilla,et al.  Power System Frequency Measurement Under Nonstationary Situations , 2008, IEEE Transactions on Power Delivery.

[3]  Predrag B. Petrovic,et al.  New algorithm for measuring 50/60 Hz AC values based on the usage of slow A/D converters , 2000, IEEE Trans. Instrum. Meas..

[4]  P. Granjon,et al.  Classification and characterization of three phase voltage dips by space vector methodology , 2005, 2005 International Conference on Future Power Systems.

[5]  B. Han,et al.  Novel phase-locked loop using adaptive linear combiner , 2006, IEEE Transactions on Power Delivery.

[6]  A. Domijan,et al.  On power quality indices and real time measurement , 2005, IEEE Transactions on Power Delivery.

[7]  Jong-Woo Choi,et al.  Digital PLL control for single-phase photovoltaic system , 2004 .

[8]  S. L. Hurst Digital protection for power systems , 1997 .

[9]  A. T. Johns,et al.  Model system tests on a new numeric method of power system frequency measurement , 1996 .

[10]  H. Lesani,et al.  New technique for frequency and amplitude estimation of power system signals , 2005 .

[11]  Dragan Jovcic,et al.  Phase locked loop system for FACTS , 2003 .

[12]  J. Svensson,et al.  Tuning software phase-locked loop for series-connected converters , 2005, IEEE Transactions on Power Delivery.

[13]  Zoran Salcic,et al.  A new method for instantaneous power system frequency measurement using reference points detection , 2000 .

[14]  L.I. Eguiluz,et al.  Three-phase adaptive frequency measurement based on Clarke's transformation , 2006, IEEE Transactions on Power Delivery.