Contribution to control strategies for converter connected to unbalanced grid

The paper deals with developed and experimentally tested effective synchronization and power control techniques for grid-connected converter. A new FLL (Frequency Locked Loop) technique is developed that incorporates advantages of both the cascaded delayed signal cancellation and dual second order generalized integrator schemes. Experimental results are evaluated in terms of quality of the positive voltage sequence, frequency and phase angle identification for the grid voltage disturbed by harmonic, subharmonic, and negative sequence components as well as for amplitude, frequency, and phase angle jumps in the voltage. A novel power control technique for grid-connected converter under unbalanced voltage conditions is referred as well. The current positive and negative sequences during grid voltage sags are controlled to assure a proper exchange of active and reactive powers without substantial power ripples, and especially, without current harmonics.

[1]  L.G. Franquelo,et al.  The age of multilevel converters arrives , 2008, IEEE Industrial Electronics Magazine.

[2]  Josep M. Guerrero,et al.  MAF-PLL With Phase-Lead Compensator , 2015, IEEE Transactions on Industrial Electronics.

[3]  Frede Blaabjerg,et al.  Multiresonant Frequency-Locked Loop for Grid Synchronization of Power Converters Under Distorted Grid Conditions , 2011, IEEE Transactions on Industrial Electronics.

[4]  Juan C. Vasquez,et al.  Flexible Voltage Support Control for Three-Phase Distributed Generation Inverters Under Grid Fault , 2013, IEEE Transactions on Industrial Electronics.

[5]  J. D. van Wyk,et al.  Evaluation of residual network distortion during compensation according to the “instantaneous power theory” , 2007 .

[6]  F. Blaabjerg,et al.  Control of Power Converters in AC Microgrids , 2012, IEEE Transactions on Power Electronics.

[7]  Fengjiang Wu,et al.  A New Two-Phase Stationary-Frame-Based Enhanced PLL for Three-Phase Grid Synchronization , 2015, IEEE Transactions on Circuits and Systems II: Express Briefs.

[8]  Vassilios G. Agelidis,et al.  Accurate Estimation of Single-Phase Grid Voltage Parameters Under Distorted Conditions , 2014, IEEE Transactions on Power Delivery.

[10]  Benjamin Kroposki,et al.  A review of power electronics interfaces for distributed energy systems towards achieving low-cost modular design , 2009 .

[11]  Fang Zheng Peng,et al.  Reactive power and harmonic compensation based on the generalized instantaneous reactive power theory for three-phase power systems , 1996 .

[12]  T.C. Green,et al.  Modeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid , 2007, IEEE Transactions on Power Electronics.

[13]  Josep M. Guerrero,et al.  Moving Average Filter Based Phase-Locked Loops: Performance Analysis and Design Guidelines , 2014, IEEE Transactions on Power Electronics.

[14]  Gerardo Escobar,et al.  Direct Power Control of a Three-Phase Rectifier Based on Positive Sequence Detection , 2014, IEEE Transactions on Industrial Electronics.

[16]  Ramon Guzman,et al.  An Adaptive Prefiltering Method to Improve the Speed/Accuracy Tradeoff of Voltage Sequence Detection Methods Under Adverse Grid Conditions , 2014, IEEE Transactions on Industrial Electronics.

[17]  Yun Wei Li,et al.  Grid synchronization PLL based on cascaded delayed signal cancellation , 2010, 2010 IEEE Energy Conversion Congress and Exposition.

[18]  Thanh-Nam Le Kompensation schnell veränderlicher Blindströme eines Drehstromverbrauchers , 1989 .

[19]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[20]  Francisco A. S. Neves,et al.  A Method for Extracting the Fundamental-Frequency Positive-Sequence Voltage Vector Based on Simple Mathematical Transformations , 2008, IEEE Transactions on Industrial Electronics.

[21]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).