Peripheral MR angiography: separation of arteries from veins with flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo imaging.

The authors evaluated a nonenhanced magnetic resonance (MR) angiographic technique that allows separation of arteries from veins. In 15 healthy subjects, peripheral MR angiography was performed with readout flow-spoiled gradient pulses in electrocardiography-triggered three-dimensional half-Fourier fast spin-echo MR imaging. Appropriate flow-spoiled gradient pulses were measured and applied in the three-dimensional acquisition to differentiate arteries and veins in the peripheral vasculature. Subtraction of the diastolic bright-blood arteries from the systolic black-blood arteries allowed visualization of the arteries by cancelling the veins, which are constantly depicted as bright blood throughout the cardiac cycle. Stronger flow-spoiled gradient pulses improved the depiction of slow-flow arteries even in the distal foot and hand vessels.

[1]  G. Laub,et al.  Moving‐table reduced‐dose gadolinium‐enhanced three‐dimensional magnetic resonance angiography: Velocity‐dependent method with three‐phase gadolinium infusion , 2001, Journal of magnetic resonance imaging : JMRI.

[2]  P. Choyke,et al.  Bolus‐chase peripheral 3D MRA using a dual‐rate contrast media injection , 2000, Journal of magnetic resonance imaging : JMRI.

[3]  J. V. van Engelshoven,et al.  Peripheral vascular tree stenoses: evaluation with moving-bed infusion-tracking MR angiography. , 1998, Radiology.

[4]  R. Meuli,et al.  Projective imaging of pulsatile flow with magnetic resonance. , 1985, Science.

[5]  M. Miyazaki,et al.  Non‐contrast‐enhanced MR angiography using 3D ECG‐synchronized half‐Fourier fast spin echo , 2000, Journal of magnetic resonance imaging : JMRI.

[6]  E. Olcott,et al.  Three‐dimensional flow‐independent peripheral angiography , 1997, Magnetic resonance in medicine.

[7]  Clinical evaluation of aortic diseases using nonenhanced MRA with ECG‐triggered 3D half‐Fourier FSE , 2001, Journal of magnetic resonance imaging : JMRI.

[8]  R. Meuli,et al.  MR gated subtraction angiography: evaluation of lower extremities. , 1986, Radiology.

[9]  A. Kassner,et al.  Stepping-table gadolinium-enhanced digital subtraction MR angiography of the aorta and lower extremity arteries: preliminary experience. , 1999, Radiology.

[10]  Yoshimori Kassai,et al.  A novel MR angiography technique: SPEED acquisition using half‐Fourier RARE , 1998, Journal of magnetic resonance imaging : JMRI.

[11]  G D Pond,et al.  MR angiography of the foot and ankle , 1995, Journal of magnetic resonance imaging : JMRI.