Evaluation of a chemical technique for determining the oxygen permeability of synthetic membranes.

The biocompatibility and high gas transfer characteristics of gas-permeable membranes have led to their use for total and supportive cardiopulmonary bypass. The gas transfer rates, particularly of oxygen, have previously been measured with sophisticated apparatus and this has restricted accurate measurements to a few laboratories. A simple chemical technique for measuring the oxygen permeability of synthetic membranes is described, in which sodium hydrosulfite is used to provide the highest possible oxygen gradient and the volume of oxygen crossing the membrane is measured volumetrically. Results agreed with those obtained with orthodox apparatus and replacement of the reducing agent with blood gave much lower oxygen transfer rates demonstrating the rheological influences of the blood upon oxygen transfer.

[1]  Heimbecker Ro Progress in extracorporeal circulation. , 1977 .

[2]  J. Vanderkooi,et al.  Oxygen diffusion in biological and artificial membranes determined by the fluorochrome pyrene , 1975, The Journal of general physiology.

[3]  M. Debakey,et al.  Membrane vs Bubble Oxygenator: Clinical Comparsion , 1975, Annals of surgery.

[4]  E. Peirce Editorial: Is the blood-gas interface of clinical importance? , 1974, The Annals of thoracic surgery.

[5]  Singh Mp,et al.  Prolonged circulatory assistance in awake neonatal lambs. , 1974 .

[6]  R. Patterson,et al.  The Landé-Edwards membrane oxygenator for total cardiopulmonary support in 110 patients during heart surgery. , 1972, Surgery.

[7]  D. Laurent,et al.  A testing device for evaluation of gas transfer through synthetic membranes. , 1970, Journal of biomedical materials research.

[8]  F. Belzer,et al.  Etiology of Rising Perfusion Pressure in Isolated Organ Perfusion , 1968, Annals of surgery.

[9]  W. L. Robb,et al.  THIN SILICONE MEMBRANES‐THEIR PERMEATION PROPERTIES AND SOME APPLICATIONS , 1968, Annals of the New York Academy of Sciences.

[10]  B. R. Baldwin,et al.  Factors Influencing Oxygen Uptake by Blood in Membrane Oxygenators: Report of a Study , 1962, Annals of surgery.

[11]  E. Fonkalsrud,et al.  Denaturation of plasma proteins as a cause of morbidity and death after intracardiac operations. , 1961, Surgery.

[12]  M. Szwarc,et al.  Permeability of Polymer Films to Gases and Vapors , 1955 .

[13]  M. Szwarc,et al.  The permeability of polymer films to gases—a simple relationship , 1955 .

[14]  I. Berger,et al.  Untersuchungen zur Beeinflussung der Enzymaktivität von Zellenzymen durch Einstrahlung von hochfrequenten elektromagnetischen Wellen im Megaherz-Bereich , 1972 .