Performance of viscous fluid dampers coupling adjacent inelastic structures under near-fault earthquakes

The behavior of viscous fluid damper applied in coupling structures subjected to near-fault earthquake was studied. The structural nonlinearity was characterized by Bouc-Wen model and several near-fault ground motions were simulated by the combination of a recorded earthquake (background ground motion) with equivalent velocity pulses that possess near-fault features. Extensive parametric studies were carried out to find the appropriate damping coefficient. Performances of viscous fluid dampers were demonstrated by the relationship between the force and displacement, the maximal damper force and stroke. The control performances were demonstrated in terms of the response reductions of adjacent structures. The results show that the dynamic responses of adjacent structures are mitigated greatly. Proper damping coefficients of connecting fluid dampers have a small difference, while adjacent structures under different near-fault ground motions with the same peak acceleration. The maximum force of damper is about 0.8 MN, and the maximum damper stroke is about ±550 mm. Satisfied viscous fluid dampers can be produced according to the current manufacturing skills.

[1]  M. De Angelis,et al.  Optimal passive control of adjacent structures interconnected with nonlinear hysteretic devices , 2007 .

[2]  Murat Dicleli,et al.  Supplemental elastic stiffness to reduce isolator displacements for seismic-isolated bridges in near-fault zones , 2007 .

[3]  Yl L. Xu,et al.  Experimental Seismic Study of Adjacent Buildings with Fluid Dampers , 2003 .

[4]  Y. Wen Method for Random Vibration of Hysteretic Systems , 1976 .

[5]  D. P. Taylor,et al.  Viscous damper development and future trends , 2001 .

[6]  Jm M. Ko,et al.  Experimental investigation of adjacent buildings connected by fluid damper , 1999 .

[7]  A. Agrawal,et al.  Analytical Model of Ground Motion Pulses for the Design and Assessment of Seismic Protective Systems , 2008 .

[8]  Yi-Qing Ni,et al.  RANDOM SEISMIC RESPONSE ANALYSIS OF ADJACENT BUILDINGS COUPLED WITH NON-LINEAR HYSTERETIC DAMPERS , 2001 .

[9]  Murat Dicleli,et al.  Equivalent linear analysis of seismic-isolated bridges subjected to near-fault ground motions with forward rupture directivity effect , 2007 .

[10]  Mohammed Ismail,et al.  The Hysteresis Bouc-Wen Model, a Survey , 2009 .

[11]  R. S. Jangid,et al.  Seismic analysis of structures connected with friction dampers , 2006 .

[12]  Michael C. Constantinou,et al.  Experimental study of seismic response of buildings with supplemental fluid dampers , 1993 .

[13]  George P. Mavroeidis,et al.  A Mathematical Representation of Near-Fault Ground Motions , 2003 .

[14]  M. D. Martínez-Rodrigo,et al.  An optimum retrofit strategy for moment resisting frames with nonlinear viscous dampers for seismic applications , 2003 .

[15]  Praveen K. Malhotra,et al.  Response of buildings to near‐field pulse‐like ground motions , 1999 .

[16]  Anil K. Chopra,et al.  Understanding and predicting effects of supplemental viscous damping on seismic response of asymmetric one‐storey systems , 2001 .

[17]  Rakesh K. Goel,et al.  Seismic response of linear and non‐linear asymmetric systems with non‐linear fluid viscous dampers , 2005 .

[18]  W. S. Zhang,et al.  VIBRATION ANALYSIS OF TWO BUILDINGS LINKED BY MAXWELL MODEL-DEFINED FLUID DAMPERS , 2000 .

[19]  Yl L. Xu,et al.  Dynamic characteristics and seismic response of adjacent buildings linked by discrete dampers , 1999 .

[20]  Zeng Qing-yuan Seismic response analysis and control of self-anchored suspension bridge , 2009 .

[21]  S. W. Park,et al.  Simulation of the seismic performance of the Bolu Viaduct subjected to near‐fault ground motions , 2004 .