The results of some simulated seismic load tests on reinforced concrete one-way interior and exterior beam-column joints with substandard reinforcing details typical of buildings constructed in New Zealand before the 1970s are described. The tests were conducted using both deformed and plain round longitudinal reinforcement. The interior beam-column joint cores lacked transverse reinforcement and the longitudinal bars passing through the joint core were poorly anchored. The exterior beam-column joint units contained very little transverse reinforcement in the members and in the joint core. In one exterior beam-column joint unit the beam bar hooks were not bent into the joint core. That is, the hooks at the ends of the top bars were bent up and the hooks at the ends of the bottom bars were bent down. This anchorage detail was common in many older buildings constructed before the 1970s. In the other exterior beam-column joint unit the hooks at the ends of the bars were bent into the joint core as in current practice. The improvement in performance of the joint with beam bars anchored according to current practice is demonstrated. In addition, tests were conducted on interior joints with lap splices in the beam longitudinal reinforcement bars near the column face. The tests were conducted using both deformed and plain round longitudinal reinforcement. Tests were also conducted on columns with plain round bar longitudinal reinforcement and inadequate transverse reinforcement. The reinforcing details were close to identical to those in an existing seven storey reinforced concrete building that was designed and built in New Zealand in the late 1950s. The test results give an indication of the performance of beam-column joints and members with the above now out-of-date reinforcing details. The test results reported are a summary of results reported in a number of publications written since 1994.
[1]
Patrick Pak Chiu Cheung.
Seismic design of reinforced concrete beam-column joints with floor slab
,
1991
.
[2]
Shigeru Hakuto,et al.
Retrofitting of reinforced concrete moment resisting frames.
,
1995
.
[3]
James L Noland,et al.
Computer-Aided Structural Engineering (CASE) Project: Decision Logic Table Formulation of ACI (American Concrete Institute) 318-77 Building Code Requirements for Reinforced Concrete for Automated Constraint Processing. Volume 1.
,
1986
.
[4]
A. Liu,et al.
Seismic behaviour and retrofit of pre-1970's as-built exterior beam-column joints reinforced by plain round bars
,
2001
.
[5]
Arthur H. Nilson,et al.
Design of concrete structures
,
1972
.
[6]
Robert Park,et al.
Evaluation of ductility of structures and structural assemblages from laboratory testing
,
1989
.
[7]
J. L. Wallace.
Behaviour of beam lap splices under seismic loading
,
1996
.
[8]
R. Park,et al.
Seismic Load Tests on Reinforced Concrete Columns Strengthened by Jacketing
,
1994
.
[9]
R. Park,et al.
Seismic Load Tests on Interior and Exterior Beam-Column Joints with Substandard Reinforcing Details
,
2000
.
[10]
T. Paulay,et al.
Reinforced Concrete Structures
,
1975
.
[11]
Aizhen Liu,et al.
Seismic load tests on two concrete interior beam-column joints reinforced by plain round bars designed to pre-1970s codes
,
1998
.