Fiber Bragg Grating-Based Triaxial Force Sensor With Parallel Flexure Hinges

During cardiac surgery, the excessive or insufficient contact force between the tip of catheter and heart tissue will lead to the cardiac penetration or noneffective ablative lesion. Usually, the surgeon can only estimate the force at the distal end roughly from their experience by operating the catheter's proximal handle. In this paper, we design a fiber Bragg grating-based triaxial force sensor with parallel flexure hinges to sense the contact force. The proposed mechanism integrated with parallel flexure hinges is capable of achieving an excellent lateral and axial stiffness balance to guarantee the resolution at each direction with the same order of magnitude. The mathematical model is built to design a suitable stiffness configuration and validate the design reasonability. The model-based and model-free methods are adopted to decouple lateral and axial force components. Experimental results demonstrate that the developed 8 French size force sensor can successfully achieve the triaxial force prediction with <1 g resolution using both decoupling methods. And the model-free method can accomplish a higher accuracy with RMS error <1% of full scale of [–100 g, 100 g] along the lateral direction and [0 g, 100 g] along the axial compression direction.

[1]  P. Polygerinos,et al.  Triaxial Catheter-Tip Force Sensor for MRI-Guided Cardiac Procedures , 2013, IEEE/ASME Transactions on Mechatronics.

[2]  Russell H. Taylor,et al.  Development of a miniaturized 3-DOF force sensing instrument for robotically assisted retinal microsurgery and preliminary results , 2014, 5th IEEE RAS/EMBS International Conference on Biomedical Robotics and Biomechatronics.

[3]  Yun Zou,et al.  A Contact-Aided Asymmetric Steerable Catheter for Atrial Fibrillation Ablation , 2017, IEEE Robotics and Automation Letters.

[4]  Hao Liu,et al.  Mechanical Model of Dexterous Continuum Manipulators With Compliant Joints and Tendon/External Force Interactions , 2017, IEEE/ASME Transactions on Mechatronics.

[5]  H. Lambert,et al.  Novel Contact Force Sensor Incorporated in Irrigated Radiofrequency Ablation Catheter Predicts Lesion Size and Incidence of Steam Pop and Thrombus , 2008, Circulation. Arrhythmia and electrophysiology.

[6]  Nadir Saoudi,et al.  The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study. , 2012, Heart rhythm.

[7]  Kaspar Althoefer,et al.  Image-Based Optical Miniaturized Three-Axis Force Sensor for Cardiac Catheterization , 2016, IEEE Sensors Journal.

[8]  Chih-Jen Lin,et al.  LIBSVM: A library for support vector machines , 2011, TIST.

[9]  Chengkuo Lee,et al.  MEMS tri-axial force sensor with an integrated mechanical stopper for guidewire applications , 2013 .

[10]  Nadir Saoudi,et al.  A novel radiofrequency ablation catheter using contact force sensing: Toccata study. , 2012, Heart rhythm.

[11]  Nobuhiko Hata,et al.  Fiber-Optic Force Sensors for MRI-Guided Interventions and Rehabilitation: A Review , 2017, IEEE Sensors Journal.

[12]  Iulian Iordachita,et al.  A Submillimetric 3-DOF Force Sensing Instrument With Integrated Fiber Bragg Grating for Retinal Microsurgery , 2014, IEEE Transactions on Biomedical Engineering.

[13]  Amit Srivastava,et al.  Design of an ultra thin strain sensor using superelastic nitinol for applications in minimally invasive surgery , 2016, 2016 IEEE International Conference on Advanced Intelligent Mechatronics (AIM).

[14]  Jeremy N Ruskin,et al.  Assessment of Catheter Tip Contact Force Resulting in Cardiac Perforation in Swine Atria Using Force Sensing Technology , 2011, Circulation. Arrhythmia and electrophysiology.

[15]  Gangbing Song,et al.  FBG Sensor for Contact Level Monitoring and Prediction of Perforation in Cardiac Ablation , 2012, Sensors.

[16]  Emiliano Schena,et al.  Optical Fiber-Based MR-Compatible Sensors for Medical Applications: An Overview , 2013, Sensors.

[17]  Berk Gonenc,et al.  FBG-based transverse and axial force-sensing micro-forceps for retinal microsurgery , 2016, 2016 IEEE SENSORS.

[18]  M. Mack,et al.  Minimally invasive and robotic surgery. , 2001, JAMA.

[19]  Hao Liu,et al.  3-DOF force-sensing micro-forceps for robot-assisted membrane peeling: Intrinsic actuation force modeling , 2016, 2016 6th IEEE International Conference on Biomedical Robotics and Biomechatronics (BioRob).

[20]  Mamun Bin Ibne Reaz,et al.  Advances in Bio-Tactile Sensors for Minimally Invasive Surgery Using the Fibre Bragg Grating Force Sensor Technique:A Survey , 2014, Sensors.