Removal of covered self-expandable metallic airway stents in benign disorders: indications, technique, and outcomes.

STUDY OBJECTIVES To describe the technique and outcome of removal of self-expandable metallic airway stents (SEMAS) in a series of patients who underwent stenting for benign airway stenoses. DESIGN AND SETTING A retrospective cohort analysis of patients with benign airway disorders treated with SEMAS between 1997 and 2003, who presented with an indication for stent removal in a tertiary-care hospital, and referral interventional pulmonology clinic. PATIENTS AND METHODS During the study period, 49 SEMAS were inserted in 39 patients for treatment of benign airway disorders. Ten of these 39 patients (25.6%), bearing 12 covered stents, presented with an indication for stent removal. Data of these cases were extracted from electronic files kept in our institution archive. RESULTS Indications for stent removal included excessive or recurrent granuloma formation (five cases), recurrence of stenosis after stent failure (one case), stent fracture (two cases), and accomplishment of treatment (two cases). In all of these cases, covered versions of SEMAS had been placed either in the trachea or in a main bronchus. In contrast to many previous reports, these stents proved to be absolutely retrievable even if some difficulties were encountered. In all cases, however, removal was successful without major complications. All patients resumed normal spontaneous ventilation postoperatively, and follow-up was uneventful. Average duration of stenting before removal was 16.2 +/- 17.5 months (+/- SD) [range, 1 to 60 months]. CONCLUSIONS We conclude that although placement of SEMAS is assumed to be permanent in patients with benign airway disorders, an indication for stent removal is often observed (25.6% in our series). The covered SEMAS can be effectively and safely removed if needed without major sequelae. Nevertheless, new technical improvements in metallic stent design and materials may help reinforce the concept of a retrievable metallic airway stent, which may offer significant clinical advantages.

[1]  J. P. Díaz-Jimenez,et al.  Silicone stents in the management of benign tracheobronchial stenoses. Tolerance and early results in 63 patients. , 1996, Chest.

[2]  A. Didier,et al.  Self-expandable prostheses in the tracheobronchial tree. , 1993, Radiology.

[3]  E. Edell,et al.  Silicone Stents versus Metal Stents for Management of Benign Tracheobronchial Disease Con: Metal Stents , 2000 .

[4]  C. Marquette,et al.  Multidisciplinary approach to management of postintubation tracheal stenoses. , 1999, The European respiratory journal.

[5]  L Labrousse,et al.  Expanding wire stents in benign tracheobronchial disease: indications and complications. , 1992, The Annals of thoracic surgery.

[6]  F Costes,et al.  Efficacy of tracheal and bronchial stent placement on respiratory functional tests. , 1995, Chest.

[7]  R. Karmy-Jones,et al.  Airway stenting for malignant and benign tracheobronchial stenosis. , 2003, The Annals of thoracic surgery.

[8]  J. Wain,et al.  Complication of benign tracheobronchial strictures by self-expanding metal stents. , 2003, The Journal of thoracic and cardiovascular surgery.

[9]  Gerard A. Silvestri,et al.  Silicone Stents versus Metal Stents for Management of Benign Tracheobronchial Disease Pro: Metal Stents , 2000 .

[10]  R. Carrau,et al.  Endoscopically placed expandable metal tracheal stents for the management of complicated tracheal stenosis. , 2003, American journal of otolaryngology.

[11]  G. Ko,et al.  Covered retrievable tracheobronchial hinged stent: an experimental study in dogs. , 2001, Journal of vascular and interventional radiology : JVIR.

[12]  Yoshihisa Nakao,et al.  New tubular bioabsorbable knitted airway stent: biocompatibility and mechanical strength. , 2002, The Journal of thoracic and cardiovascular surgery.

[13]  Atul C Mehta,et al.  Self-expandable metallic airway stents and flexible bronchoscopy: long-term outcomes analysis. , 2003, Chest.

[14]  J. Orens,et al.  High dose rate brachytherapy to prevent recurrent benign hyperplasia in lung transplant bronchi: theoretical and clinical considerations. , 2000, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[15]  A. Mehta,et al.  Stenting of the tracheobronchial tree. , 2000, Radiologic clinics of North America.

[16]  Mukesh Prasad,et al.  Endoscopically placed nitinol stents for pediatric tracheal obstruction. , 2002, International journal of pediatric otorhinolaryngology.

[17]  J. Orens,et al.  Removal and repositioning of "permanent" expandable wire stents in bronchial airway stenosis after lung transplantation. , 1998, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[18]  G. Jung,et al.  Tracheobronchial strictures: treatment with a polyurethane-covered retrievable expandable nitinol stent--initial experience. , 1999, Radiology.

[19]  M. Noppen,et al.  The Wrong Stent at the Wrong Time: A Cautionary Tale , 2003, Respiration.

[20]  M. Kramer,et al.  High dose rate brachytherapy for nonmalignant airway obstruction: new treatment option. , 2003, Chest.

[21]  P. Törmälä,et al.  Bioabsorbable self-reinforced poly-L-lactide, metallic, and silicone stents in the management of experimental tracheal stenosis. , 1999, Chest.

[22]  K. Kovitz,et al.  Seven-Year Experience with the Dumon Prosthesis , 1996 .