A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants.

Total hip arthroplasty is a widespread surgical approach for treating severe osteoarthritis of the human hip. Aseptic loosening of standard metallic hip implants due to stress shielding and bone loss has motivated the development of new materials for hip prostheses. Numerically, a three-dimensional finite element (FE) model that mimicked hip implants was used to compare a new hip stem to two commercially available implants. The hip implants simulated were a novel CF/PA12 carbon-fibre polyamide-based composite hip stem, the Exeter hip stem (Stryker, Mahwah, NJ, USA), and the Omnifit Eon (Stryker, Mahwah, NJ, USA). A virtual axial load of 3 kN was applied to the FE model. Strain and stress distributions were computed. Experimentally, the three hip stems had their distal portions rigidly mounted and had strain gauges placed along the surface at 3 medial and 3 lateral locations. Axial loads of 3 kN were applied. Measurements of axial stiffness and strain were taken and compared to FE analysis. The overall linear correlation between FE model versus experimental strains showed reasonable results for the lines-of-best-fit for the Composite (Pearson R(2)=0.69, slope=0.82), Exeter (Pearson R(2)=0.78, slope=0.59), and Omnifit (Pearson R(2)=0.66, slope=0.45), with some divergence for the most distal strain locations. From FE analysis, the von Mises stress range for the Composite stem was much lower than that in the Omnifit and Exeter implants by 200% and 45%, respectively. The preliminary experiments showed that the Composite stem stiffness (1982 N/mm) was lower than the metallic hip stem stiffnesses (Exeter, 2460 N/mm; Omnifit, 2543 N/mm). This is the first assessment of stress, strain, and stiffness of the CF/PA12 carbon-fibre hip stem compared to standard commercially-available devices.

[1]  M. Niinomi,et al.  Aging behavior of the Ti-29Nb-13Ta-4.6Zr new beta alloy for medical implants , 2002 .

[2]  P Christel,et al.  Development of a carbon-carbon hip prosthesis. , 1987, Journal of biomedical materials research.

[3]  J. Galante,et al.  ESB Research Award 1992. The mechanism of bone remodeling and resorption around press-fitted THA stems. , 1993, Journal of biomechanics.

[4]  M. Philippe,et al.  Influence of the microstructure on the pseudoelasticity of a metastable beta titanium alloy , 2005 .

[5]  R. Zdero,et al.  A biomechanical assessment of modular and monoblock revision hip implants using FE analysis and strain gage measurements , 2010, Journal of orthopaedic surgery and research.

[6]  E. Schneider,et al.  Influence of muscle forces on femoral strain distribution. , 1998, Journal of biomechanics.

[7]  S. Carmichael,et al.  Biomechanics of total hip arthroplasty , 1999, The Anatomical record.

[8]  J. K. Spelt,et al.  Finite element analysis of a femoral retrograde intramedullary nail subject to gait loading. , 2004, Medical engineering & physics.

[9]  J. Galante,et al.  Mechanisms of bone loss associated with total hip replacement. , 1993, The Orthopedic clinics of North America.

[10]  L. Yahia,et al.  Bone remodeling in a new biomimetic polymer-composite hip stem. , 2010, Journal of biomedical materials research. Part A.

[11]  R. Zdero,et al.  Biomechanical evaluation of periprosthetic femoral fracture fixation. , 2008, The Journal of bone and joint surgery. American volume.

[12]  Mitsuo Niinomi,et al.  Recent research and development in titanium alloys for biomedical applications and healthcare goods , 2003 .

[13]  Baldev Raj,et al.  Corrosion of bio implants , 2003 .

[14]  R. Brand,et al.  Pelvic muscle and acetabular contact forces during gait. , 1997, Journal of biomechanics.

[15]  R Zdero,et al.  The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs. , 2007, Journal of biomechanical engineering.

[16]  Ulrich Simon,et al.  Changes in strain distribution of loaded proximal femora caused by different types of cementless femoral stems. , 2006, Clinical biomechanics.

[17]  Wilson C. Hayes,et al.  Basic Orthopaedic Biomechanics , 1995 .

[18]  H. Jergesen,et al.  Total hip arthroplasty. , 1995, The Western journal of medicine.

[19]  L. Yahia,et al.  Biocompatibility of novel polymer-apatite nanocomposite fibers. , 2008, Journal of biomedical materials research. Part A.

[20]  L. Yahia,et al.  Performance of CF/PA12 composite femoral stems , 2008, Journal of materials science. Materials in medicine.

[21]  John J. Callaghan,et al.  The Adult Hip , 1997 .

[22]  R. Zdero,et al.  Cyclic loading of periprosthetic fracture fixation constructs. , 2008, The Journal of trauma.

[23]  William R Taylor,et al.  Influence of changes in stem positioning on femoral loading after THR using a short-stemmed hip implant. , 2007, Clinical biomechanics.

[24]  V. Frankel,et al.  Biomechanics of the Hip , 1984 .

[25]  R. Pilliar,et al.  Cobalt-base alloys for biomedical applications , 1999 .

[26]  Joseph D. Bronzino,et al.  Biomechanics: Principles and Applications , 2002 .

[27]  M. Steinberg The Hip and Its Disorders , 1990 .

[28]  M. Hardisty,et al.  The biomechanics of the T2 femoral nailing system: A comparison of synthetic femurs with finite element analysis , 2009, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[29]  Aurelian Vadean,et al.  Design of a biomimetic polymer-composite hip prosthesis. , 2007, Journal of biomedical materials research. Part A.

[30]  L Cristofolini,et al.  Experimental investigation of bone remodelling using composite femurs. , 2003, Clinical biomechanics.

[31]  D R Sumner,et al.  Functional adaptation and ingrowth of bone vary as a function of hip implant stiffness. , 1998, Journal of biomechanics.

[32]  D. Poitout,et al.  Biomechanics and Biomaterials in Orthopedics , 2004 .

[33]  M. Akay,et al.  Numerical and experimental stress analysis of a polymeric composite hip joint prosthesis. , 1996, Journal of biomedical materials research.

[34]  G. Bergmann,et al.  Hip joint loading during walking and running, measured in two patients. , 1993, Journal of biomechanics.

[35]  N. Sugano,et al.  Longitudinal Evaluation of Time Related Bone Remodeling After Cementless Total Hip Arthroplasty , 1997, Clinical orthopaedics and related research.