Modelling and Passivity Analysis of VSC Output Impedance under SRF and αβ Control Frames

Passivity property of input impedance of grid connected Voltage Source Converter (VSC) is a good measure for ensuring small signal stability of the power system composed of numerous interconnected dynamical system. It is well known that a pure passivity for a VSC is impossible to obtain, however, if the frequency range of the negative admittance from VSC terminal can be minimized, the possibility instability due to grid side impedance interacting with the VSC system can be reduced. For a VSC, there are two major design alternatives for the current controller;a decoupled dq current controller and αβ frame Proportional Resonant controller. This paper compares these two current controller alternatives for VSC, based on their passivity property. The small signal model of LCL filter equipped VSC with the two types of current controller is also derived. Some design recommendations using the considered current controllers, for reducing non-passive frequency range is also presented.

[1]  Brian B. Johnson,et al.  An Interaction-Admittance Model for Multi-Inverter Grid-Connected Systems , 2019, IEEE Transactions on Power Electronics.

[2]  Xu Cai,et al.  A Modified Sequence-Domain Impedance Definition and Its Equivalence to the dq-Domain Impedance Definition for the Stability Analysis of AC Power Electronic Systems , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[3]  Milan Prodanovic,et al.  Stability analysis for weak grids with power electronics interfaces , 2016, IECON 2016 - 42nd Annual Conference of the IEEE Industrial Electronics Society.

[4]  Jian Sun,et al.  Impedance Modeling and Analysis of Grid-Connected Voltage-Source Converters , 2014, IEEE Transactions on Power Electronics.

[5]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[6]  Ha Thi Nguyen,et al.  Combination of Synchronous Condenser and Synthetic Inertia for Frequency Stability Enhancement in Low-Inertia Systems , 2019, IEEE Transactions on Sustainable Energy.

[7]  Bo Wen,et al.  Input impedance of voltage source converter with stationary frame linear current regulators and phase-locked loop , 2013, 2013 IEEE Energy Conversion Congress and Exposition.

[8]  Frede Blaabjerg,et al.  Unified Impedance Model of Grid-Connected Voltage-Source Converters , 2018, IEEE Transactions on Power Electronics.

[9]  Gevork B. Gharehpetian,et al.  Power System Stability Analysis Using Feedback Control System Modeling Including HVDC Transmission Links , 2016, IEEE Transactions on Power Systems.

[10]  Donald Grahame Holmes,et al.  Stationary frame current regulation of PWM inverters with zero steady state error , 1999, 30th Annual IEEE Power Electronics Specialists Conference. Record. (Cat. No.99CH36321).

[11]  Bo Wen,et al.  Analysis of D-Q Small-Signal Impedance of Grid-Tied Inverters , 2016, IEEE Transactions on Power Electronics.

[12]  Donald Grahame Holmes,et al.  Frequency domain analysis of three phase linear current regulators , 1999 .

[13]  Frede Blaabjerg,et al.  Passivity-Based Stability Assessment of Grid-Connected VSCs—An Overview , 2016, IEEE Journal of Emerging and Selected Topics in Power Electronics.

[14]  Bo Wen,et al.  Impedance-Based Analysis of Grid-Synchronization Stability for Three-Phase Paralleled Converters , 2014, IEEE Transactions on Power Electronics.

[15]  Massimo Bongiorno,et al.  Input-Admittance Calculation and Shaping for Controlled Voltage-Source Converters , 2007, IEEE Transactions on Industrial Electronics.