Passive test cell data for the solar laboratory, Winter 1980-81
暂无分享,去创建一个
Testing was done during the 1980-81 winter in 400 ft/sup 3/ test cells at the Los Alamos National Laboratory Solar Lab. This testing was done primarily to determine the relative efficiency of various passive solar heating concepts and to obtain data that could be used to validate computer simulation programs. The passive solar systems tested were Trombe wall with and without selective absorber, water wall, phase-change wall, direct gain, a heat-pipe collector, and two sunspace geometries. The heating load coefficient of these cells was roughly 26 Btu/h /sup 0/F and the collector area was 23.4 ft/sup 2/, giving a load collector ratio of approximately 27 Btu//sup 0/F day ft/sup 2/. The test cell configurations and instrumentation are detailed herein, and the resulting data and cell efficiencies are discussed.